@name@name

Debe insertar un cable en el terminal OT 1 y el otro cable en el terminal OT. MODULO DE INTERFAZ DE SENSOR PARA EXTERIORES (50022037) EXTERIOR C70809U MS23812 OT 1 PANEL W8835 SENSOR DE TEMPERATURA 2 3 1 2 3 OT Fig. 1. Diagrama de conexion del modulo de interfaz desensor para exteriores. OUTDOOR SENSOR INTERFACE MODULE OUTDOOR SENSOR INTERFACE MODULE Honeywell International Inc. Honeywell Limited-Honeywell Limitee 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario

Скачали: 10   Размер: 477 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name@name@name

• there is good air circulation. • it can measure true outdoor ambient temperature. • surface is flat. • wire distance between C7089 and thermostat is less than 200 feet. Do not mount the sensor: • in direct sunlight. • where hot or cold air blows on the sensor. Discharge line from an outdoor compressor unit, vent or fan causes inaccurate temperature readings. • where snow, ice or debris can cover it. Use the following steps to mount the sensor: 1. Remove the sensor from the mounting clip. 2. Ma

Скачали: 2   Размер: 140 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

1 Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. INSTALLATION INSTRUCTIONS 3 Installer must be a trained, experienced service technician. 4 After installation is complete, check out product operation as provided in these instructions. CAUTION Disconnect power supply before connecting wiring to prevent elect

Скачали: 1   Размер: 2 mb   Производитель: Honeywell  
Категория: Прочие инструменты
@name@name@name

Once a remote indoor temperature sensor is connected to the thermostat, the thermostat’s sensor is no longer used. The thermostat’s installer setup should be modified to tell the thermostat that remote indoor temperature sensor(s) have been used. The Inside temperature reading on the thermostat’s display will be the remote sensor(s) temperature location(s). Fig. 1. C7189U Remote Indoor Sensor SPECIFICATIONS Operating Ambient Temperature Range: 45 to 88°F (7.2 to 32°C). Display Range: 0 to 99°F (

Скачали: 0   Размер: 362 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

CAUTION This product is not intended to be used for life or safety applications. CAUTION This product is not intended for use in any hazardous or classified locations. INSTALLATION Make sure that all installations are in compliance with all national and local electrical codes. Only qualified individuals that are familiar with codes, standards, and proper safety procedures for high-voltage installations should attempt installation. The current sensor is a 2- wire, 4 to 20 mA Loop Powered device t

Скачали: 10   Размер: 362 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

The recommended torque to be used on the terminal block connections is 5.93 in-lbs (0.67 Nm). The 62-0245—01 2 SOLID CORE AND SPLIT CORE 4-20 MA OUTPUT CURRENT SENSORS SOLID CORE AND SPLIT CORE 4-20 MA OUTPUT CURRENT SENSORS BUILDING AUTOMATION SYSTEM COMMON + 4-20 MA SIGNAL INPUT GND (SHIELD) + – +12-30 VDC DC POWER SUPPLY + – M23934 Fig. 6. Wiring example OPERATING SPECIFICATIONS Max Sensing Current Voltage: 600 Vac Table 1. Specifications by Product Number Product Number Core Type Output Rang

Скачали: 4   Размер: 725 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

The C7400S communicates temperature and humidity separately digitally on the Sylk Bus Communication Protocol. A separate controller such as the JADE™ Economizer System (Model W7220) provides power and communications on the Sylk Bus for the C7400S Sylk Bus sensor. SPECIFICATIONS Electrical Supply Voltage: 7 to 21 Vdc Power Consumption: 5 mA Output Rating: 75 ohm load switched at 9600 Baud Wiring: Sylk Bus: 2-wire (18 to 22 AWG) Environmental Operating Temperature range: -40 to 150 °F (-40 to 65 °

Скачали: 6   Размер: 197 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

SPECIFICATIONS IMPORTANT The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications. This product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. Models: T7047C: 2-wire remote sensor with no internal adjustment means (requires remote setpoint device such as S963B, T7067B, and T7080B). T7047C

Скачали: 10   Размер: 197 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

14. Two T7047G1000 Sensors providing a temperature-averaging network for a T7300/Q7300 Thermostat/Subbase. Q7300 T T M3422 T T T7047GT T T7047G T T T7047G T T T7047G T T T7047G Fig. 15. Five T7047G1000 Sensors providing a temperature-averaging network for a T7300/Q7300 Thermostat/Subbase. Q7300 T T M3419 T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C T T T7047C Fig. 16. Nine T7047C1025 Sensors providing a temperature-averaging network for a T7300/Q7300 Th

Скачали: 14   Размер: 232 kb   Производитель: Honeywell  
Категория: Прочие инструменты
@name

T7147 Remote Sensor and Override Module PRODUCT DATA FEATURES • Locking cover. • Override key. • Warmer/Cooler keys on some models. • Key-lock override security available. Contents Application ........................................................................ 1 Features ........................................................................... 1 Specifications ................................................................... 2 Ordering Information .......................................





Категории