Войти:
Оценок - 2, средний балл: 5 ( )

Инструкция по эксплуатации Cleveland, модель PGM

Производитель: Cleveland
Размер: 2.53 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


WEEKLY 1. Check the door gasket for wear and reverse or replace the gasket when needed. 2. Pour a liquid chemical descaler down the back of each compartment drain. C. MONTHLY 1. Every 3 to 4 months the generator should be opened and checked for mineral build up or Chloride corrosion. Look to see if the generator has a buildup of scale greater than the thickness of a business card or if the top is beginning to peel off in layers. If either one of these conditions is present, the generator needs to be chemically descaled by your CLEVELAND AUTHORIZED SERVICE AGENCY. a. Inspect more frequently in areas where the water conditions do not meet the Water Quality Requirements. 1. Change the boiler gasket every time you open the boiler for liability reasons. 2. Check to see that all door fasteners are tight. Check to see that all steam, water, and electrical connections are secure. If any are loose contact your authorized service agency to make the REPAIRS It is in your best interest to maintain as many preventive maintenance records as possible. When contacted by a customer or service agency the manufacturer appreciates having this information available. The record keeping chart that is provided with the steam generator would assist you and your service agency. It will help you record your maintenance and service history of the equipment. If you have any questions concerning the proper installation and maintenance of your CLEVELAND STEAM COOKER call the Cleveland Service Department at (216) 4814900. Operator’s Manual P/N-260APC-A ______________________________________________________________________________ 10 Descaling is the most important maintenance you can perform on a steam cooker, and is required by the Cleveland Range warranty. The Descaling Pump System circulates DISSOLVE descaling liquid through the boiler of the steamer. Recirculating the descaling liquid provides a faster and more thorough cleaning process than the conventional soaking process. The Descaling Pump System consists of a submersible pump, a 5-gallon reservoir pail, Hand-Hole plate with ports, the feed and drain hoses, and the temporary hose couplings necessary to connect the system to the Classic Series Cleveland Steamers. Descaling Procedure Convection Steamers Pressure Steamers SteamPro/Convection Pro Modular Boiler Bases (Using the Descaling Pump System) Cleveland Range has developed the Descaling Pump System for owners of the Classic Series Convection Steamers, Pressure Steamers and SteamPro/Convection Pro series steam cookers. The Pump System provides a fast, highly efficient way to descale Cleveland Steam Cookers. The descaling Pump Kit includes a temporary hand-hole plate that is equipped with two descaling ports, one for the inlet and one for the outlet. This is to be used only for the Pump Kit and replaced at the end of the procedure. Operator’s Manual P/N-260APC-A NOTE: Only service technicians authorized by Cleveland Range should perform the descaling procedure. Read and be familiar with the procedure before starting. Follow the procedure exactly as given. DISSOLVE Descaling Liquid Use only Cleveland Range DISSOLVE descaling product. Five gallons of descaling liquid will be needed during this procedure. Avoid unnecessary contact with the descaling product; read and follow safety precautions on the container label. DISSOLVE Order Quantities Container Size Qty Part No. 1-gallon bottles 6 106174 5-gallon pail 1 1061741 5-gallon pails 12 10617411 5-gallon pails 24 10617412 Overview of Pump Descaling Procedures Below is a summary of the descaling procedure using the Pump System. The detailed procedure is given on page 3 and 4. Descaling should be done as required by your maintenance schedule. The process takes about an hour and a half to complete. Part A – Equipment Setup • Turn off the steamer to drain the boiler • Remove the handhold plate of the boiler and attach the hand-hole plate with the descaling ports • Connect feed and drain hoses • Fill reservoir pail with DISSOLVE descaling liquid and insert pump. Part B – Descaling • Turn on power to steamer; boiler will begin to fill • Turn on pump • Monitor liquid levels in boiler and pail- regulate level using hand valves • Let liquid circulate for one hour • Turn OFF steamer, pump; boiler will drain Part C – Clean Water Flush • Turn On steamer; boiler will fill • Empty the pail of spent solution, refill with fresh water • Route Drain hose to floor drain • Turn pump ON and circulate for 5 minutes, monitoring water levels • Turn OFF pump; close all valves; turn OFF steamer; boiler will drain • Replace hand-hole plate, check gasket Part D –Take Down and Return to Service • Turn ON Steamer; boiler will fill • Remove hoses and couplings; • Activate steam switch; unit ready to operate ______________________________________________________________________________ 11 Operator’s Manual P/N-260APC-A Detail Procedure- Using the Descaling Pump System A. Equipment Setup 1. Turn the Steamer OFF; the...

Эта инструкция также подходит к моделям:
Плиты - PDM (2.53 mb)
Плиты - PDL-2/3 (2.53 mb)
Плиты - PEM (2.53 mb)
Плиты - PSM (2.53 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории