l Check 1) Coincide the center mark and the point. (See Chapter 2 “PREPARATION FOR MEASUREMENT”.) 2) Rotate the instrument 180° or 200g around the vertical axis and check the center mark. If the point is properly centered in the center mark, adjustment is not required. Otherwise, adjust in the following manner. l Adjustment 1) Take off the adjustment section cover of the optical plummet telescope eyepiece. This will expose four capstan adjustment screws which should be adjusted with the accessor