2.36”) • Height limit: below 25ft. • Maximum tubing length: below 50ft. Tubing length over 25ft. 9/12 Btuh (Single or Multi-Zone) • Charge additional refrigerant amount, Parts of Indoor Unit No. Part Qty 1 Remote Control 1/unit 2 Remote Control Fixture 1/unit 3 Batteries 'LR03' (AAA) 2/unit 4 Manual 1 Parts of Outdoor Unit No. Part Qty 1 9/12 Btuh 4 Rubber Cushion 2 18/24 Btuh 4 Rubber Cushion 3 Drain Pipe 1 DETERMINATION OF INSTALLING POSITION Install the Air Conditioner(s) by taking into account the following points, upon the customer’s consent. • Make sure that the indoor unit(s) are installed high enough, over 6 feet, (beyond reach of young children). Indoor Unit • Do not install the unit(s) near a heat source. • Be sure that air outlet and inlet are not obstructed. • Be sure all clearances are as specified in the above figure (front, upper, left and right of the unit(s)). • Allow convenient drainage and piping connection with the outdoor unit. • Avoid installing the unit(s) in direct sunlight. • Install the unit(s) on walls that can support their weight. ! CAUTION ! • Be sure chosen location can properly support the weight of the unit(s) and will provide adequate damping of vibration and noise. Outdoor Unit • Insure chosen location can provide adequate drainage and good ventilation. • Do not install in an area with flammable or corrosive vapors. Avoid salty air or sulfuric gas areas. • Be sure all clearances are specified in the above figure (front, upper, left, right and rear of the unit) and also open on more than two sides. • Be sure hot exhaust and noise does not bother the customer or their neighbors. • Do not allow hot exhaust to blow directly on pets and plants. ! CAUTION ! • Read this installation manual thoroughly before installing the air conditioner(s) for proper installation. • All field wiring must be installed by a licensed electrician and must comply with all national and local codes. • All field piping must be installed by a licensed refrigeration technician and must comply with all national and local codes. • Never plug unit(s) into an electrical outlet. • Do not touch compressor, pipes and valves without protective gloves during and after operation, because these parts may become hot (more than 100°C (212°F). • Explain the operating procedure of the air conditioner to the customer. Outdoor unit mounting leg dimension additional refrigerant amount =0.22oz./ft.>25’. 18/24 Btuh (Single Zone Only) • Charge additional refrigerant amount, ECR International Hyundai Ductless Split System11 MOUNTING OF THE INSTALLATION PLATE MOUNTING OF THE INSTALLATION PLATE Position the installation plate and check that it is level. IMPORTANT: Always mount the installation plate horizontally by aligning the marking line with the thread or using a level. 2. Mount the installation plate horizontally and securely on structural members (studs, etc.) in the wall with four (4) installing screws. (See Fig. 1) 3. Make a 2 9/16” hole through the wall. Hole...
Эта инструкция также подходит к моделям:Кондиционеры - HACM09DB - HCCM99DB (947.49 kb)
Кондиционеры - HACM12DB - HCCM22DB (947.49 kb)
Кондиционеры - HACM12DB - HCCM22DB (947.49 kb)
Кондиционеры - HACM09DB - HCCM99DB (947.49 kb)