ECR International Hyundai Ductless Split System10 additional refrigerant amount =0.44oz./ft.>25’. • Capacity drops slightly. More than 12” More than 2” More than 16” More than 4” More than 10” INSTALLATION (Single Zone Shown) NOTE: Always check superheat and subcooling of system. (22.72”) 9/12 Btuh (23.94”) 18/24 Btuh (8.86”) 9 Btuh( 11.02”) 12 Btuh(14.25”) 18/24 Btuh Distance between the unit(s) and ceiling should be more than 2” Clearance in front of unit(s) should be no less than 10’ Distance between the unit(s) and the wall should be more than 6” Fasten the unit(s) on the lower hook of wall plate Fasten the unit(s) on the upper hook of wall plate Distance between the unit(s) and the wall should be more than 6” Wall plate Patch Outgoing tubing (bottom) Wall cap Connecting wire Through the wall tubing (O.D. 2.36”) • Height limit: below 25ft. • Maximum tubing length: below 50ft. Tubing length over 25ft. 9/12 Btuh (Single or Multi-Zone) • Charge additional refrigerant amount, additional refrigerant amount =0.44oz./ft.>25’. • Capacity drops slightly. More than 12” More than 2” More than 16” More than 4” More than 10” INSTALLATION (Single Zone Shown) NOTE: Always check superheat and subcooling of system. (22.72”) 9/12 Btuh (23.94”) 18/24 Btuh (8.86”) 9 Btuh( 11.02”) 12 Btuh(14.25”) 18/24 Btuh Distance between the unit(s) and ceiling should be more than 2” Clearance in front of unit(s) should be no less than 10’ Distance between the unit(s) and the wall should be more than 6” Fasten the unit(s) on the lower hook of wall plate Fasten the unit(s) on the upper hook of wall plate Distance between the unit(s) and the wall should be more than 6” Wall plate Patch Outgoing tubing (bottom) Wall cap Connecting wire Through the wall tubing (O.D. 2.36”) • Height limit: below 25ft. • Maximum tubing length: below 50ft. Tubing length over 25ft. 9/12 Btuh (Single or Multi-Zone) • Charge additional refrigerant amount, Parts of Indoor Unit No. Part Qty 1 Remote Control 1/unit 2 Remote Control Fixture 1/unit 3 Batteries 'LR03' (AAA) 2/unit 4 Manual 1 Parts of Outdoor Unit No. Part Qty 1 9/12 Btuh 4 Rubber Cushion 2 18/24 Btuh 4 Rubber Cushion 3 Drain Pipe 1 DETERMINATION OF INSTALLING POSITION Install the Air Conditioner(s) by taking into account the following points, upon the customer’s consent. • Make sure that the indoor unit(s) are installed high enough, over 6 feet, (beyond reach of young children). Indoor Unit • Do not install the unit(s) near a heat source. • Be sure that air outlet and inlet are not obstructed. • Be sure all clearances are as specified in the above figure (front, upper, left and right of the unit(s)). • Allow convenient drainage and piping connection with the outdoor unit. • Avoid installing the unit(s) in direct sunlight. • Install the unit(s) on walls that can support their weight. ! CAUTION ! • Be sure chosen location can properly support the weight of the unit(s) and will provide adequate damping of vibration and noise. Outdoor Unit • Insu...
Эта инструкция также подходит к моделям:Кондиционеры - HACM09DB - HCCM99DB (947.49 kb)
Кондиционеры - HACM12DB - HCCM22DB (947.49 kb)
Кондиционеры - HACM12DB - HCCM22DB (947.49 kb)
Кондиционеры - HACM09DB - HCCM99DB (947.49 kb)