Войти:
Оценок - 4, средний балл: 3.3 ( )

Инструкция по эксплуатации Danby, модель HACM09DB - HCCM99DB

Производитель: Danby
Размер: 947.49 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• When connecting the indoor unit(s) to the outdoor unit please be sure to connect the same number on the indoor and outdoor unit terminal blocks. • Be sure to use approved connecting wire (14 gauge minimum). • When installing the air conditioner, please be sure to use the right power supply cable conforming to Canadian Electrical Code/National Electrical Code. NOTE: Interconnecting voltage is 208/230V. • The air conditioner always requires grounding. • Grounding must conform to local regulations. HYUNDAI ELECTRICAL INTER-CONNECT REVISION “B” PRODUCT Cool Model HCW9000/HCW12000/HMCW18000/HMCW24000 Cool and Heat Model HHW12000/HMHW18000/HMHW24000 HHW18000/HHW24000 NOTE: Gnd is Earth Ground HACW/HACM are cooling only indoor units HCCW/HCCM are cooling only outdoor units HAHW is heat pump indoor unit HCHW is heat pump outdoor unit NOTE: For Multi-zone systems, there are two sets of identical wiring terminals. Be sure to match each air handler with its corresponding terminal strip connection. Use above diagram for each circuit. HCW18000/HCW24000 ! CAUTION ! • Connect one end of the ground wire to the outdoor unit ground terminal. • Use minimum 14 AWG wire conductors between the indoor and outdoor units. • Refer to page 16 to determine the wire size from the power ECR International Hyundai Ductless Split System14 ! CAUTION ! CONNECTING OF POWER SOURCE Before supplying the power, check that the voltage is within +6% of the rated voltage marked on the indoor unit label(s). supply to the condenser. ! CAUTION ! Make sure wire connections are secure otherwise electrical malfunction may occur. TEST RUN TEST RUN • After the test, set the lever to ON (I) position. The unit will stop the operation and hereafter the remote control will • Check the installation again. control the unit. • First, set the lever to OFF(O) position, then to ON(I) and TEST position slowly. (During the test, the indicator light will blink) 9/12 Btuh 18/24 Btuh CABLE CONNECTION 9/12 Btuh (Single or Multi-Zone) 1. Wiring between units should be cut to length. 2. Remove the wiring cover of the Indoor Unit(s) and the Outdoor Unit. 3. Insert the connection wire into the terminal block. ECR International Hyundai Ductless Split System15 CABLE CONNECTION 18/24 Btuh (Single Zone Only) ELECTRICAL SPECIFICATIONS AND SYSTEM PERFORMANCE 4. Fix the connecting wire between units, with wiring fixture. 5. Attach the wiring cover. CABLE CONNECTION 18/24 Btuh (Single Zone Only) ELECTRICAL SPECIFICATIONS AND SYSTEM PERFORMANCE 4. Fix the connecting wire between units, with wiring fixture. 5. Attach the wiring cover. Cooling Capacity SEER Heating Capacity (Btuh) (2) HSPF Volts/HZ/Phase Total Amps MCA Max. Fuse Nominal (1) Sensible HCW9000 9,500 7,030 10.9 --208/230/60/1 5.0 6.1 15 HCW12000 12,000 8,760 10.6 --208/230/60/1 6.2 7.6 15 HHW12000 12,000 8,760 10.4 12,500 7.2 208/230/60/1 6.2 7.6 15 HCW18000 20,000 14,200 10.7 --208/230/60/1 10.2 12.5 20 HHW18000 20,000 14,200 10.3 20,000 6.9 208/230/60/1 10.2 1...

Эта инструкция также подходит к моделям:
Кондиционеры - HACM09DB - HCCM99DB (947.49 kb)
Кондиционеры - HACM12DB - HCCM22DB (947.49 kb)
Кондиционеры - HACM12DB - HCCM22DB (947.49 kb)
Кондиционеры - HACM09DB - HCCM99DB (947.49 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории