Инструкция по эксплуатации Goodman Mfg, модель HACW09DB - HCCW09DB

Производитель: Goodman Mfg
Размер: 947.49 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


· 9/12 Btuh ·:Blink ing Trouble Check by Self-Test ModeState of LED Contents of Defect (Green) LED · Defect of room temperature sensor (Orange) LED · Defect of indoor heat exchanger sensor ·18/24 Btuh ·:Blinking Trouble Check by Self-Test Mode Contents of Defect (Green) LED · Defect of room temperature sensor (Red) LED ( ) · Defect of indoor heat exchanger sensor (Green) LED · Defect of compressor protection circuit (Cooling only Model) When self-diagnosis is cleared it returns to normal operation. ECR International Hyundai Ductless Split System10 additional refrigerant amount =0.44oz./ft.>25’. • Capacity drops slightly. More than 12” More than 2” More than 16” More than 4” More than 10” INSTALLATION (Single Zone Shown) NOTE: Always check superheat and subcooling of system. (22.72”) 9/12 Btuh (23.94”) 18/24 Btuh (8.86”) 9 Btuh( 11.02”) 12 Btuh(14.25”) 18/24 Btuh Distance between the unit(s) and ceiling should be more than 2” Clearance in front of unit(s) should be no less than 10’ Distance between the unit(s) and the wall should be more than 6” Fasten the unit(s) on the lower hook of wall plate Fasten the unit(s) on the upper hook of wall plate Distance between the unit(s) and the wall should be more than 6” Wall plate Patch Outgoing tubing (bottom) Wall cap Connecting wire Through the wall tubing (O.D. 2.36”) • Height limit: below 25ft. • Maximum tubing length: below 50ft. Tubing length over 25ft. 9/12 Btuh (Single or Multi-Zone) • Charge additional refrigerant amount, additional refrigerant amount =0.44oz./ft.>25’. • Capacity drops slightly. More than 12” More than 2” More than 16” More than 4” More than 10” INSTALLATION (Single Zone Shown) NOTE: Always check superheat and subcooling of system. (22.72”) 9/12 Btuh (23.94”) 18/24 Btuh (8.86”) 9 Btuh( 11.02”) 12 Btuh(14.25”) 18/24 Btuh Distance between the unit(s) and ceiling should be more than 2” Clearance in front of unit(s) should be no less than 10’ Distance between the unit(s) and the wall should be more than 6” Fasten the unit(s) on the lower hook of wall plate Fasten the unit(s) on the upper hook of wall plate Distance between the unit(s) and the wall should be more than 6” Wall plate Patch Outgoing tubing (bottom) Wall cap Connecting wire Through the wall tubing (O.D. 2.36”) • Height limit: below 25ft. • Maximum tubing length: below 50ft. Tubing length over 25ft. 9/12 Btuh (Single or Multi-Zone) • Charge additional refrigerant amount, Parts of Indoor Unit No. Part Qty 1 Remote Control 1/unit 2 Remote Control Fixture 1/unit 3 Batteries 'LR03' (AAA) 2/unit 4 Manual 1 Parts of Outdoor Unit No. Part Qty 1 9/12 Btuh 4 Rubber Cushion 2 18/24 Btuh 4 Rubber Cushion 3 Drain Pipe 1 DETERMINATION OF INSTALLING POSITION Install the Air Conditioner(s) by taking into account the following points, upon the customer’s consent. • Make sure that the indoor unit(s) are installed high enough, over 6 feet, (beyond reach of young children). Indoor Unit • Do not install the unit(s) near a heat source. • Be sure...

Эта инструкция также подходит к моделям:
Кондиционеры - HACM09DB - HCCM99DB (947.49 kb)
Кондиционеры - HACM12DB - HCCM22DB (947.49 kb)
Кондиционеры - HACM12DB - HCCM22DB (947.49 kb)
Кондиционеры - HACM09DB - HCCM99DB (947.49 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории