Войти:
Сортировка : Названию ↑   Загрузкам   Оценке   Размеру ↑  
Скачали: 20   Размер: 909 kb   Производитель: Regency  
Категория: Камины
@name

(1.25 kPa) 12” W.C. (3.00 kPa) Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa) Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 3.3” W.C. (0.82 kPa) Orifi ce Size #44 DMS - 0-2000ft #45 DMS - 2000-4500ft #54 DMS Minimum Input Altitude 0-2000 ft. (0-610m) 12,500 BTU/h (3.66 kW) 10,500 BTU/h (3.07 kW)Minimum Input Altitude 2000-4500 ft. (610-1372m) 10,500 BTU/h (3.07 kW) Maximum Input Altitude 0-2000 ft. (0-610m) 22,500 BTU/h (6.59 kW) 21,500 BTU/h (6.30 kW)Maximum Input Altitude 200

Скачали: 2   Размер: 293 kb   Производитель: Regency  
Категория: Камины
@name

This versatile fireplace can be installed almost anywhere in your home to provide up to 18,500 BTU of consistent, controllable heat, operating even during power outages. Enjoy multiple styling options: choose sleek flush panels or traditional full screen doors, one of 3 realistic brick styles, or stainless steel inset panels to match your home décor. Specifications Natural Gas Propane Input (BTU) 18,500 17,500 Turn Down to (BTU) 12,500 14,500 EnerGuide Rating* 61.60% 64.32% Efficiency (stea

Скачали: 1   Размер: 1007 kb   Производитель: Regency  
Категория: Камины
@name

N, 04/2010 MODELS VF5000-CMN-2 VF6000-CMN-2 VF5000-CMP-2 VF6000-CMP-2 USPortland Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Donottrytolightanyappliance. • Donottouchanyelectricalswitch;donotuseany phone in your building. • Immediatelycallyourgassupplierfromaneighbor’sphone.Followthegassupplier'sinstructions. • Ifyoucannotreachyourgassupplier,callthe fire department. Installation and service must

Скачали: 21   Размер: 20 mb   Производитель: Regency  
Категория: Камины
@name

1) Make sure the valve is in the "OFF" position. 2) Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide flat screwdriver. 3) Attach manometer to "IN" and/or "OUT" pressure tap(s) using a 5/16" ID hose. G36D-NG1 System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes: #42 Max. Input Rating 26,000 Btu/h Min. Input Rating 13,100 Btu/h Supply Pressure min.5.0" w.c. Manifold Pressure (High) 3.8"+/- 0.2"w.c. Log Set: Ceramic fibre, 7 per set. Vent System:

Скачали: 1   Размер: 599 kb   Производитель: Regency  
Категория: Камины
@name

If this occurs, it is preferable to contact your nearest dealer to service the appliance. Alternatively, at least annually, the glass enclosure panel should be removed and the inside of the firebox and the control compartments cleaned using a vacuum cleaner to remove dust. Remove the top and bottom logs, gently handling by holding each log at each end and set on a piece of paper or cloth to avoid getting any debris on carpet or floor. Use the vacuum cleaner to remove the embers from the base and

Скачали: 0   Размер: 2 mb   Производитель: Regency  
Категория: Камины
@name

MEASURE FLUE FROM HEATER CENTER-LINE A D BACKWALL SIDEWALLB E G G I BACKWALL SIDEWALLSIDEWALL H J F ADJACENT WALL SIDEWALLC MANUFACTURED BY: FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 VENTURE ST. DELTA, BC V4G 1H4 SIDEWALL G 255 mm / 10 in I 570 mm / 22.5in BACKWALL H 115 mm / 4.5in J 290 mm / 11.5in 2001 20032002 * In Canada, floor protection must extend 18" to the front and 8" to each side of the stove. Regency Freestanding Woodstove SAFETY LABEL This is a copy of the label that accompanies of

Скачали: 25   Размер: 9 mb   Производитель: Regency  
Категория: Камины
@name

This could cause high temperatures and may present the possibility of a fire. b) The location of the horizontal vent termination on an exterior wall must meet all local and national building codes, and must not be blocked or obstructed. See "Exterior Vent Termination Locations" section for more details. 7) Ensure that the pipe clearances to combustible materials are maintained (Diagram 5). Install the termination cap. Note: If installing termination on a vinyl siding covered wall, a vinyl siding

Скачали: 18   Размер: 1 mb   Производитель: Regency  
Категория: Камины
@name

If you should experience any problem, first refer to the trouble shooting guide in this manual. If problem persists, contact your Lennox distributor. WIRING DIAGRAMS Wiring diagrams are provided here for reference purposes only. This information is also provided on schematics attached directly to the appliance on a pullout panel located within the control compartment. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS APPLIANCE

Скачали: 2   Размер: 3 mb   Производитель: Regency  
Категория: Камины
@name

Shown with black louvers, brick panels and contour faceplate. Optional Features • Glass bay front • Louvers • Full screen doors • Glass trim (bay front only) • Brick panels • Faceplates • Hearth trims - various sizes • FireGenie® Remote Control • Wall thermostat • New fireplace kit • Regency flex venting • LP conversion kit 16 Liberty L234 gas insert featuring a contemporary faceplate, brick panels and hearth riser. The Regency® Liberty L234 is a clean front fireplace insert that will slide easi

Скачали: 1   Размер: 599 kb   Производитель: Regency  
Категория: Камины
@name

Please read and understand these instructions completely before beginning your installation. This document covers four models of Catalytic Fireplaces. Instructions are provided for all models and many alternative installations for each. Therefore, certain details may not be applicable to your model and may not be required for your application. GENERAL INFORMATION The Catalytic Fireplaces covered in this manual feature ceramic fiber split logs which glow realistically when the heater is operating





Категории