Фрагмент инструкции


(1.25 kPa) 12” W.C. (3.00 kPa) Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa) Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 3.3” W.C. (0.82 kPa) Orifi ce Size #44 DMS - 0-2000ft #45 DMS - 2000-4500ft #54 DMS Minimum Input Altitude 0-2000 ft. (0-610m) 12,500 BTU/h (3.66 kW) 10,500 BTU/h (3.07 kW)Minimum Input Altitude 2000-4500 ft. (610-1372m) 10,500 BTU/h (3.07 kW) Maximum Input Altitude 0-2000 ft. (0-610m) 22,500 BTU/h (6.59 kW) 21,500 BTU/h (6.30 kW)Maximum Input Altitude 2000-4500 ft. (610-1372m) 21,000 BTU/h (6.15 kW) Vent Sizing 4” Inner / 6 5/8” Outer 4” Inner / 6 5/8” Outer Approved Venting Systems Flex Vent Systems: FPI AstroCap™ Flex Vent Rigid Pipe Vent Systems: Simpson Direct Vent Pro® American Metal Products® Amerivent Direct Security Secure Vent® Selkirk Direct-Temp™ Metal-Fab® Sure Seal ADC F M AE Unit Dimensions Description P33 A Front Face Width 33” (838mm) B Rear Firebox Width 23” (584mm) C Front Face Height 29” (737mm) D Height w/ Standoff 31 1/2” (800mm) E Unit Depth 12-3/4” (324mm) F Firebox Height 28 1/2” (724mm) Framing Dimensions Description P33 G Framing Width 33-1/4” (845mm) H*** Framing Height*** 31-3/4” (806mm)*** I Framing Depth Vertical 19 1/2” (495mm) Vertical Rise 16 1/2” (419mm) Rigid 12-3/4” (324mm) FlexHorizontal J Corner Wall Length 37 1/2” (953mm) K Corner Facing Wall Width 53-1/4” (1353mm) L Framed Chase Ceiling 36” (914mm) Rigid 32” (813mm) Flex M Vent Centerline Height 30” (762mm) Rigid 26” (660mm) Flex N K J OP Q 10" (254mm) dia. Hole through wall Vent. Top Header R Opening for gasconnection B G H I L Drywall (or other facing) Dimension Description P33 N Gas Connection Height 1 1/2” (38mm) O Gas Connection Inset 4” (102mm) P Gas Connection Width 3” (76mm) Q Minimum Framing Depth 16 1/2” (419mm) Rigid / 12-3/4” (324mm) Flex R Maximum Framing Depth (including wall thickness) 40 1/2” (419mm) Rigid / 36-3/4” (324mm) Flex Please refer to Exterior Vent Terminations for ***Important: Framing height requires consideration of the hearth additional guidelines on vent locations. depth. Dimension H = H + the thickness of installed hearth. 28 August 2008 Product Specifi cations Book Gas Fireplaces Gas Fireplaces P33 Gas Fireplace Model P33-NG4 w/ Contemporary Faceplate P33-LP4 w/ Contemporary Faceplate Fuel Type Natural Gas Propane Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (3.00 kPa) Manifold Pressure - High 3.8” W.C. (0.95 kPa) 11” W.C. (2.74 kPa) Manifold Pressure - Low 1.1” W.C. (0.27 kPa) 3.3” W.C. (0.82 kPa) Orifice Size #47 DMS #56 DMS Minimum Input Altitude 0-4500 ft. (0-1372m) 9,800 BTU/h (2.87 kW) 9,000 BTU/h (2.64 kW) Maximum Input Altitude 0-4500 ft. (0-1372m) 17,500 BTU/h (5.13 kW) 15,500 BTU/h (4.54 kW) Vent Sizing 4” Inner / 6 5/8” Outer 4” Inner / 6 5/8” Outer Approved Venting Systems Flex Vent Systems: FPI AstroCap™ Flex Vent Rigid Pipe Vent Systems: Simpson Direct Vent Pro® American Metal Products® Amerivent Direct Security Secure Vent® Selkirk Direct-Temp™ Metal-Fab® Sure Seal Dimension Description P33S O Gas Connection Height 1 1/2” (38mm) P Gas Connection Inset 4” (102mm) Q Gas Connection Width 3” (76mm) R Minimum Framing Depth 16 1/2” (419mm) Rigid / 12-3/4” (324mm) Flex S Maximum Framing Depth (including wall thickness) 40 1/2” (1028mm) Rigid / 36-3/4” (933mm) Flex Unit Dimensions Description P33 with Contemporary Faceplate A Front Face Width 33” (838mm) B Rear Firebox Width 23” (584mm) C Front Face Height 29” (737mm) D Height w/ Standoff 31 1/2” (800mm) E Unit Depth 12-3/4” (324mm) F Firebox Height 29” (737mm) Framing Dimensions Description P33 with Contemporary Faceplate G Framing Width 33-1/4” (845mm) H** Framing Height** 31-3/4” (806mm)** I* Framing Rise from Floor 1” (25mm) minimum* J Framing Depth Vertical 19 1/2” (495mm) Vertical Rise 16 1/2” (419mm) Rigid 12-3/4” (324mm) FlexHorizontal K Corner Wall Length 37 1/2” (953mm) L Corner Facing Wall Width 53-1/4” (1353mm) M*** Framed Chase Ceiling*** 36” (914mm) Rigid*** 32” (813mm) Flex*** N Vent Centerline Height 30” (762mm) Rigid 26” (660mm) Flex * The unit must be raised a minimum of 1” above the finished fl oor. ** Dimension H = H + I (minimum) *** Dimension M = M + I (minimum) Important: If the Contemporary Faceplate is used on the P33-NG4/P33LP4 Gas Fireplace, the burner orifice (Both NG/LP supplied in package) must be replaced and an overlay decal (also supplied with kit) must be affixed to the current serial number decal supplied with unit. Note: Also see framing dimensions for this optional front if installed on the P33-4 unit. Note: Unit must be raised up by 1' to allow for faceplate installation. NG LP Current P33-4 orifice size: #44 #54 Must replace with: #47 #56 Warning: Fire hazard is an extreme risk if these changes are not adhered to. Gas Fireplaces August 2008 Product Specifi cations Book 29 Gas Fireplaces Gas Fireplaces Gas Fireplaces P33 Gas Fireplace Framing and Finishing 1) Determine the total thickness of facing material (e.g. drywall plus ceramic tiles) to ...

Эта инструкция также подходит к моделям:
Камины - 946-523/P (909.23 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории