Figure 6.3 Minimum Clearances for Termination CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. WARNING! In the U.S.: Vent system termination is NOT permitted in screened porches. You must follow side wall, overhang and ground clearances as stated in the instructions. In Canada: Vent system termination is NOT permitted in screened porches. Vent system termination is permitted in porch areas with two or more sides open. You must fo

Скачали: 0   Размер: 5 mb   Производитель: Quadra-Fire  
Категория: Камины
@name

Example 2: If the equivalent length of pipe is 12 feet (3.7m) with altitude of 6,000 feet (1829m) you may use 3 or 4 inch (76 to 102mm) diameter type “L” or “PL” vent Fire Risk. Do NOT pack insulation or other combustibles between firestops. • ALWAYS maintain specified clearances around venting and firestop systems. • Install firestops as specified. Failure to keep insulation or other material away from vent pipe may cause fire. WARNING Page 14 7014-188B February 3, 2010 R R February 3, 2010 701

Скачали: 6   Размер: 6 mb   Производитель: Quadra-Fire  
Категория: Камины
@name

Failure to follow these instructions could result in property damage, bodily injury or even death. • Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appliance. • Do not overfi re - If any external part starts to glow, you are overfi ring. Reduce feed rate. Overfi ring will void your warranty. • Comply with all minimum clearances to combustibles as specifi ed. Failure to comply may cause house fi re. Check building codes prior to installati

Скачали: 4   Размер: 2 mb   Производитель: Quadra-Fire  
Категория: Камины
@name

B • 12/08 7 77 Installation Preparation Prepare the existing solid fuel masonry or factory built non-combustible firebox for installation. A. Inspection and Cleaning Prior to installing the gas insert: • Have the chimney and adjacent structure inspected and cleaned by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certified professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimn

Скачали: 7   Размер: 6 mb   Производитель: Quadra-Fire  
Категория: Камины
@name

• By: Qualified Service Technician/Homeowner Be sure the appliance is allowed to cool, has been unplugged and the exhaust blower is off. The products of combustion will contain small particles of fly ash. The fly ash will collect in the exhaust venting system and restrict the flow of the flue gases. At start-up if there is incomplete combustion, or if there is a shutdown or incorrect operation of the appliance it will lead to some soot formation. This will collect in the exhaust venting system.

Скачали: 1   Размер: 6 mb   Производитель: Quadra-Fire  
Категория: Камины
@name

Shelled Field Corn (Cont’d) corn used. In cases where it is acceptable for the appliance to run full time, 100% corn will work after the fire has been started using wood pellets. When purchasing corn to burn in your appliance, read the ingredient label very carefully. Do NOT purchase fuel that contains any additives such as oils (i.e. soybean oil) and meals as it will result in poor unit performance. If you are buying corn the only ingredient that should be listed is corn. Shelled field corn mus

Скачали: 3   Размер: 6 mb   Производитель: Quadra-Fire  
Категория: Камины
@name

•The liner must be securely attached to the insert flue collar and the chimney top. •The air flow of the factory-built zero-clearance fireplace system must not be altered. The flue liner top support attachment must not reduce the air flow for the existing air-cooled chimney system. •No dilution air is allowed to enter the chimney. 1. Secure the fireplace damper in the open position. If this cannot be accomplished, it will be necessary to remove the damper 2. Seal damper area of chimney around ch

Скачали: 0   Размер: 2 mb   Производитель: Quadra-Fire  
Категория: Камины
@name

Be sure to release air pressure from the gas line before connection is made totheappliance.Excessivepressurewilldamagethegas control and may cause a gas leak. • GasLeakTest:Makesurethegasconnectionsaretight. Turn on the gas and coat each joint with a non-corrosive gas leak check solution. Air bubbles will form indicating any leaks. DO NOT USE A FLAME OR ANY TYPE OF IGNITION SOURCE TO CHECK FOR LEAKS. All leaks must be corrected before proceeding with installation. 0 Quadra-Fire • Fogata Grande O

Скачали: 0   Размер: 5 mb   Производитель: Quadra-Fire  
Категория: Камины
@name

• Do not store or use gasoline or other flammable vapors and liquids in the vicinity ofthis or any other appliance. • What to do if you smell gas: -Do not try to light any appliance. -Do not touch any electrical switch. Do notuse any phone in your building. -Immediately call your gas supplier froma neighbor’s phone. Follow the gas supplier’s instructions. -If you cannot reach your gas supplier, call the fi re department. • Installation and service must be performed by a qualified installer, serv

Скачали: 0   Размер: 4 mb   Производитель: Quadra-Fire  
Категория: Камины
@name

the jumper wires across the terminals at the switch. If the burner the valve knob is in the ON comes on, replace the defective switch. If the switch is OK, place the position, and the ON/OFF jumper wires across the switch wires at the gas valve. If the burner switch is in the ON position. comes on, the wires are faulty or connections are bad. b. Thermopile may not be gener- If the pilot flame is not close enough physically to the thermopile, ating suffi cient millivoltage. adjust the pilot flame