Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Stovax, модель DT-400CEN

Производитель: Stovax
Размер: 973.7 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


HORIZONTAL (OUTSIDE WALL) TERMINATION SYSTEM HORIZONTAL (OUTSIDE WALL) TERMINATION SYSTEM Secure Vent SV4.5 direct vent system components are unitized concentric pipe components featuring positive twist lock connection, (refer to Figure 15 on page 10). All of the appliances covered in this document are fitted with collars having locking inclined channels. The dimpled end of the vent components fit over the appliance collar to create the positive twist lock connection. A. Plan the vent run Analyze the vent routing and determine the types and quantities of sections required 4 ..." (114 mm), 10 ..." (267 mm), 22 ..." (572 mm), 34 ..." (876 mm) and 46 ..." (1181 mm) net section lengths are available. Make allowances for elbows as indicated in Figure 18 on page 10. Maintain a minimum 1" (25 mm) clearance to combustibles on the vertical sections. Clearances for the horizontal runs are; 3" (76 mm) on top, 1" (25 mm) on sides, and 1" (25 mm) at the bottom. B. Frame exterior wall opening Locate the center of the vent outlet on the exterior wall according to the dimensions shown in Figure 9on page 7. Cut and/or frame an opening, 10..." x 12..." (267 mm x 308mm) inside dimensions, about this center. C. Frame ceiling opening -If the vertical route is to penetrate a ceiling, use plumb line to locate the center above the appliance. Cut and/or frame an opening, 10..." x 10..." (267 mm x 267 mm) inside dimensions, about this center (refer to Figure 14on page 10 ). D. Attach vent components to appliance -To attach a vent component to the appliance collar, align the dimpled end over the collar, adjusting the radial alignment until the four locking dimples are aligned with the inlets of the four incline channels on the collar (refer toFigure 15 on page 10). Push the vent component against the collar until it fully engages, then twist the component clockwise, running the dimples down and along the incline channels until they seat at the end of the channels. The unitized design of the Secure Vent components will engage and seal both the inner and outer pipe elements with the same procedure. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Vertical Rise SV4.5E90 Elbow Horizontal / Inclined Run SV4.5HTSSL Termination Shown *CeilingFirestop/Spacer(SV4.5BF) SV4.5L6/12/24/36/48 Vent Sections Support Bracket SpacingEvery 5 ft (1.52 m) See Figure 17 on page 10for vertical vent section support. SupportBracketsBuildingSupport Framing Ceiling Fireplace Exterior Wall Exterior Wall TYPICAL HORIZONTAL VENT INSTALLATION Firestop/Spacer SV4.5HTSSL Termination Shown Fireplace *When using Secure Flex use Firestop/Spacer(SF4.5BF) Figure 28 H. Change vent direction -At transition from or to a horizontal/inclined run, install the SV4.5E45 and SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element. Twist elbow sections in a clockwise direction only so as to avoid the possiblity of unlocking any of the previously connected vent sections. See Figure 18 on page 11. F. Install firestop/spacer at ceiling When using Secure Vent, use SV4.5BF fir- estop/spacer at ceiling joists; when using Secure Flex, use SF4.5BF firestop/spacer. If there is living space above the ceiling level, the fir- estop/ spacer must be installed on the bottom side of the ceiling. If attic space is above the ceiling, the firestop/ spacer must be installed on the top side of the joist. Route the vent sections through the framed opening and secure the firestop/spacer with 8d nails or other appropriate fasteners at each corner. Note:An elbow may also be attached...

Эта инструкция также подходит к моделям:
Камины - DT-400CEP (973.7 kb)
Камины - DT-400CEN (973.7 kb)
Камины - DT-400CEP (973.7 kb)
Камины - DR-400CEN (973.7 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории