|
Фрагмент инструкции
Turn off the gas supply to the appliance. discard the three pressure regulator mounting Remove the front glass door/frame from the screws. Remove the pressure regulator, spring, appliance. Access the control compartment. poppet, diaphragm and bushing. Discard all removed components. Ensure the rubber gas- Step 2. Carefully remove the logs. Exercise ket installed on the back of the replacement care as not to break the logs. pressure regulator is properly positioned and install the new pressure regulator using the Step 3. Locate the screws securing the burner new screws supplied with the kit. Tighten (tray) to the appliance. Remove the burner and screws to 25 In. lb. torque. retain the securing screws. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. AVERTISSEMENT: CET EQUIPEMENT DE CONVERSION SERA INSTALLEPAR UNE AGENCE QUALIFIEE DE SERVICE CONFORMEMENT AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET CODES APPLICABLES DE L'AUTORISES AVOIR LA JURIDICTION. SI L'INFORMATION DANS CETTE INSTRUCTION N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE PROTOXYDE DE CARBONE PEUT RESULTER LE DOMMAGES CAUSER DE PROPRIETE, PERTE OU BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIEE DE SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET EQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET COMPLETE JUSQU'A L'OPERATION DE L'APPAREIL CONVERTI EST CHEQUE SUIVANT LES CRITERES ETABLIS DANS LES INSTRUCTIONS DE PROPRIETAIRE PROVISIONNEES AVEC L'EQUIPEMENT. Natural To Propane Gas Conversion Kit (Honeywell Systems) Models No. Unit Type Catalog No. DT-400 millivolt 26M51 DR-400 millivolt 26M51 DT-400 electronic 99L90 DR-400 electronic 99L90 Propane to Natural Gas Conversion Kit (Honeywell Systems) Model No. Unit Type Catalog No. DT-400 millivolt 26M55 DR-400 millivolt 26M55 DT-400 electronic 99L91 DR-400 electronic 99L91 SIT Millivolt Gas Valve Pressure Regulator Remove These Components Figure 59 7/16 in. Open End Wrench Orifice Strip Tab Pilot Orifice 7/16 in. Open End Wrench Orifice Strip Tab Pilot Orifice b. Attach manometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.0 inches water column (2.49 kPa) for propane gas. c. Refer to Figure 60 and remove the pilot hood assembly to access the hexed pilot orifice. Remove and replace the orifice with the one provided with the kit. Step 5. Millivolt Appliances - Honeywell Systems a.Convert the gas valve as follows (seeFigure 61): Remove the plastic protecting cap. Remove the gas type setting screw by turning it counterclockwise. Obtain the replacement gas type setting screw from the kit and screw it into place (red for propane and blue for natural gas). Tighten the gas type setting screw by turning it clockwise. Replace the plastic protecting cap. Adjusting Knob Conversion screw (blue natural gas; red LP/propane gas) Regulator Cap Honeywell Millivolt Gas Valve Figure 61 Pilot for Honeywell Millivolt Gas Valve (Loosening of Hex Fitting For Orifice Strip Tab Positioning) Hood Hood Alignment Take Care Not to Contact the Orifice Strip Tab with the Hex Fitting Wrench - Distortion of the Tab May Render the Pilot Inoperative. Figure 62 Pilot for Honeywell Millivolt Gas Valve Pilot for Honeywell Millivolt Gas Valve Orifice Strip Tab Positioning Figure 63 Natural Gas Position NAT shown on tab LP/Propane Gas Position 1/ 16 in. Hole, LP and Red Color shown on tab NAT P LOrifice Strip Tab Position Identification For LP/Propane and Natural Gas Top View of Hex Fitting and Orifice Strip Tab Note - Orifice Strip Tab May Be Randomly Located On AnySide Of The Hex Fitting Figure 64 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Orifice Strip Tab Pilot Hood Position After L...
Эта инструкция также подходит к моделям:Камины - DT-400CEP (973.7 kb)
Камины - DT-400CEN (973.7 kb)
Камины - DT-400CEP (973.7 kb)
Камины - DR-400CEN (973.7 kb)