Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Superior, модель DR-400CEP

Производитель: Superior
Размер: 973.7 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


** In accordance with the curent ANSI SZ223.1/NFPA 54 National Fuel Gas Codes. ‡ A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings. *‡ Only permitted if veranda, porch, deck or balcony is fully open on a minimum 2 sides beneath the floor: Figure 8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. V NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. *34.... (872) Back wall of chase/enclosure (including any finishing materials) a 8.... (208) b Note- Venting requirements for rear vent applications in corner installations - the round termination (SV4.5HTR) may not be used- the horizontal vent length “a” to “b,” must not exceed 28 inches (711 mm) *17.... (437) Inches (millimeters) *These dimensions occur when one 45 degree elbow is connected directly to the appliance collar and the unit moved ... in. (13 mm) into the room. This ... in. movement is required to achieve a min. of 5 in (127 mm) in the F dimension. *F = 5 in. (127 mm) *24... (616) 33... (841) *48... (1232) CORNER FRAMING WITH SQUARE HORIZONTAL TERMINATIONS (SV4.5HTSSL, SV4.5HTSS or SV4.5HTS) SV4.5HTSS & SV4.5HTSSL Termination Framing should be constructed of 2x4 or larger lumber. 7 (178) b SV4.5HTS Termination 7 (178)5... 12... (308) 10... (267) VENT FRAMING TOP VENT WITH ONE 90° ELBOW VENT FRAMING REAR VENT WITH NO ELBOWS Framing should be constructed of 2x4 or larger lumber. Inches (mm) (130) 5... (130) 7 (308) 12... (178) *12... inches (327 mm) is the required framing depth dimension when the finish material (drywall) thickness is 1/2 in. (13mm). *12... (327) 33... (845) 33... (845) 16... (422) 37... (943) 19... (498) **FRAMING WITH SQUARE HORIZONTAL TERMINATIONS (SV4.5HTSSL, SV4.5HTSS or SV4.5HTS) AND ROUND HORIZONTAL TERMINATION (SV4.5HTR) ** See the horizontal venting Figures 35and 36 on page 16 for restrictions on theuse of the round termination (SV4.5HTR) Figure 9 Figure 10 FIREPLACE FRAMING SPECIFICATIONS NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 21... (546) 13 (330) ... (13) 1... (42) 8..... (212) 3 (76) Top View NOTE - Eyebrow hood shown as positioned in louvered front model. *CONCENTRIC FLUE FLUE - 4... (114) COMBUSTION AIR - 7... (190) FRAMING SPACERS (Top and Sides and Rear) GAS INLET (Either Side and bottom) Front View 3 (76) (Louvered Front Model Shown) **Rear vent models only ELECTRICAL INLET 2... x 2 (70 x 51) COVER PLATE with KNOCKOUT) Right Side View *DR models have only a rear vent*DT models have only a top vent6..... (173) 2... (70) 33... (841) 30... (765)27... (699) 17 (432) **19... (498) 10... (273) 33... (841) Inches (millimeters) 1 (25) 1 (25) VENT RESTRICTOR INSTALLATION (TOP VENT) In all venting applications using the top vent of the appliance, a vent restrictor may be needed. Install the vent restrictor in the top vent of the appliance outlet. RESTRICTOR APPLIANCE TOP VENT OUTLET If needed, install the restrictor orientated as shown, either from inside or outside the unit, in the inner fireplace collar. INNER FIREPLACE COLLAR Figure 11 Figure 12 Step 3. INSTALL THE VENT SYSTEM General Information These instructions should be used as a guideline and do not supersede local codes in any way. Install vent according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 and B149.2 in Canada. These fireplaces are designed, tested and listed for operation and installation with, and only with, Secure Vent™ (SV 4.5) Direct Vent System Components, Secure Flex™ Flexible Vent Components manufactured by Security Chimneys International. These approved vent system components are labeled for identification. FIREPLACE SPECIFICA...

Эта инструкция также подходит к моделям:
Камины - DT-400CEP (973.7 kb)
Камины - DT-400CEN (973.7 kb)
Камины - DT-400CEP (973.7 kb)
Камины - DR-400CEN (973.7 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории