PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. Figure 1 Description Leading Edge air curtains produce a wall of continuously flowing air that acts as a thermal barrier against outside air and flying insects. These air curtains maintain interior conditioned temperature and prevent heated or cooled air from escaping through open doorways. They redu
Use adequate size wire for all branch and feeder runs. 2. Install all wiring, protection and grounding in accordance with the National Electrical Code (NEC) and all local requirements. WARNING: THIS FAN HAS AN INTERNAL SELF RESETTING THERMAL OVERLOAD PROTECTOR. ALWAYS DISCONNECT FROM POWER SUPPLY BEFORE SERVICING. CAPACITOR AMP PLUG GREEN RED BLACK RED M F HI SPEED LOW SPEED EARTH WHITE BLACK HI SWITCH BLACKBLACKBLACKBLACKBLACKGREENGND BLACK L1 COMMON WHITE LOW MOTOR (W) N (B) L2 3. Remove two s
Connect ground to screw provided. 9. Inspect to make sure wiring is per “Single Phase Wiring” above. 2 TOP VIEW SIDE VIEW HeaterWall Wall Wall Floor Ceiling Chain 3' (914.4mm) Min. 3' (914.4mm) Min. 2' (609.6mm) Min. 10' (3048mm) Min. ELECTRIC SHOCK HAZARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property damage. Heater must be effectively grounded in accordance with the National Electrical Code, NFPA 70. All electrical wiri
STEP 7—Stand assembly upright with motor at top and position shutter on outside of frame. Secure shutter with (8) wood or lag screws (number 12 x 1” preferred) through holes in shutter frame. See Fig. 3. STEP 8—To mount this attic fan in gable or wall, a box must be framed into wall construction as shown in Fig. 4. See wall opening in chart. FAN SIZE “A” & “B” DIMENSIONS WALL OPENING SIZE 30” 33 3/4” x 33 3/4” 34” x 34” 36” 39 3/4” x 39 3/4” 40” x 40” STEP 9—Insert frame containing fan and shutt
C. CAUTION: Incorrect wiring can cause motor failure and possible fire. Marley Engineered Products will not accept liability for damage resulting from incorrect wiring. FOLLOW ALL WIRING DIAGRAMS AND ALL INSTRUCTIONS CAREFULLY. D. This fan is designed to run on 120 volt A.C., 60 Hz power only. STEP 2 - The 3-speed control packed with this fan is used to operate fan from a remote wall location. Generally the best location is in the hallway near the fan. The control should be in sight of the fan.
(Fig. 10.) Install grommet in bracket (Fig. 10) and attach on each end of fan, using two of the short screws provided. Position fan over opening so that grommets are resting against center joist. Attach fan and brackets to center joist with the two long wood screws and flat washers. Do not crush grommet when tightening screws. FIG. 10 FIG. 11 GROMMET BRACKET GASKET STEP 6 - Attach side panels to fan as shown using remaining short screws and washers. (See Fig. 11.) Bottom panels should rest upon
Available in nonlocking and locking. See Table 1. Ground Fault Kits WMGF240 series kit mounts to wall that de-energizes the heater prior to element failure. See instruction sheet 5200-2652-###. Model Wattage Volts Amps Cord Guage Cord Set Locking Plug Set Non-Locking Plug Set L1511B 1500 120 12.5 See Note See Note See Note Note: This hand carry model includes cord and standard 3-prong gounded plug. L2081B L2021B L2071B L2041B L2061B 2000 208 240 277 480 600 9.6 8.3 7.2 4.2 3.3 14/3 14/3 14/3 14/
PH4ABPortableUnitHeater FILE#E21609 Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Products. You have made a wise investment selecting the highest quality product in the heating indus- try. Please carefully read the installation and maintenance directions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the indus- try’s lea
This heater has hot and arcing or sparking parts inside. Do NOT use in areas where gasoline, paint or other flammable liquids are used or stored. 5. This heater is intended to provide temporary, supplemental localized heat only in non-residential locations. The heater is intended for use on the floor only. Do NOT place heater on surface where is could fall or tip over. 6. Heater element operates at very hot temperatures. Do NOT place heater near combustibles and DONOT place combustibles in the r
Please carefully read the installation and maintenance instructions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the industry’s leader in design, manufacturing, quality and service. ... The Employees of Marley Engineered Products WARNING ! Read Carefully - This Instruction Sheet Contains Vital Information For The Proper Assembly, Set-Up And Efficient Operation Of The Heater. Carefully Read The Manual Before Assembl