PH4ABPortableUnitHeater FILE#E21609 Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Products. You have made a wise investment selecting the highest quality product in the heating indus- try. Please carefully read the installation and maintenance directions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the indus- try’s leader in design, manufacturing, quality and service. ... The Employees of Marley Engineered Products WARNING ! Read Carefully -These instructions contain vital infor- mation for the proper installation, use and efficient opera- tion of the heater. Carefully read these instructions before installation, operation, or cleaning of the heater. Failure to adhere to the instructions could result in fire, electric shock, serious personal injury, death or property damage. Save these instructions and review frequently for continu- ing safe operation and instruction future users. 1. Connect to properly grounded outlets only. 2. Check heater voltage and amperage on back of heater to make sure it agrees with the electric service supplied. 3. Ground fault circuit protection is required if heater is used in damp areas such as basements or garages. This is not suit- able for use in wet or very humid locations. 4. Do not use outdoors. 5. Never locate heater where it may fall into a bathtub or other water container. 6. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, fire, or damage the heater. 7. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use soft surfaces, like a bed, where openings may become blocked. Clean as often as neces- sary to prevent dust from clogging the grilles or element fins. Keep all electrical cords, drapes, paper, plastics and other combustibles away from heater. 8. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, etc. To prevent entanglement or damage, route cord away from high traffic areas. 9. A heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are repaired by a reputable repair service. 10. If this heater or its power cord become damaged or malfunc- tion in any way, unplug heater, discontinue use, and have unit repaired by a reputable repair service. 11. Do not operate heater without stand. 12. Do not use an extension cord with this heater. Do not cut off plug and wire heater directly. 13. When heater is to be wall or ceiling mounted, the anchoring provisions must be of sufficient strength to support the total weight of the heater plus the weight of the mounting provi- sions. Failure to properly secure the supporting members of the building structure could allow the heater to fall. SAVE THESE INSTRUCTIONS 1 GENERAL Prior to operating heating, make sure the electrical outlet is of the configu- ration and capacity appropriate for the heater. When heater is wall or ceiling mounting, provisions must be made to bun- dle or otherwise prevent excess power cord from draping loose. In workshops, locate heater away from sources of wood dust. FLOOR APPLICATION The heater, as received, is set up for floor mounting. Place the heater on floor or other flat surface and insert the plug into the proper wall outlet. The heater can be adjusted to redirect the airstream. To do this, simply loosen the knob on either side of the heater, then pivot heater to desired position and re-tighten both knobs. WARNING ! BE CAREFUL NOT TO DIRECT THE AIRSTREAM AT DRAPERIES, FURNITURE, OR OTHER OBJECTS THAT COULD BE DAMAGED BY HEAT. DO NOT USE HEATER ON FLOOR WITHOUT STAND IN PLACE. DO NOT SUE THE HEATER WHERE A SMALL CHILD MAY FALL OVER THE HEATER. DO NOT PLACE THE HEATER WHERE THE POWER CORD MAY BE WALKED ON, TRIPPED OVER, OR OTH- ERWISE SUBJECTED TO HARD USAGE. WALL MOUNT SEE WARNING NO. 13. This heater may be mounted on any wall that will support the weight of the heater. First remove the mounting stand from the heater, then remove four rubber grommets from stand. Secure stand to structural members of wall with four 1/4” dia. X 1-1/2” long lag bolts (not provided). In masonry walls use metal expansion shields or toggle bolts. Never use bolts smaller 1/4” diameter. Replace the heater in the stand and tighten knobs to lock in place. Two KEYHOLE SLOT MOUNTING HOLES ARE 16” O.C. USE KEYHOLES FOR WALL MOUNTING large rubber washers go between heater and stand, one on either side. REMEMBER: The electrical outlet must be within reach of the six foot cord. Be sure to provide enough clearance to pivot heater and reach adjustment knobs. CEILING MOUNT This heater may be mounted to any ceiling that will support the weight of the heater. First remove the mounting stand from the heater, then remove four rubber WARNING ! TO PREVENT HEATER FROM POSSIBLY ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории