Фрагмент инструкции


If you choose to drill through the metal door frame, this must be done before the handle holes are located and drilled in the panel. Illustration 8 shows how this hole passes through the door frame. The hole center is on the small locator groove in the front of the frame. A 6 mm diameter hole is made in the front wall of the extrusion and a 11 mm diameter hole through the rest of the frame. The wine storage unit door is made with a sealed double wall tempered glass core. The drill must not contact this core when drilling. Be sure the hole is centered on the small groove in the front of the door frame and the drill passes squarely through the frame. If you are inexperienced with drilling, fasten the handle from the rear of the door panel only. Sub-Zero allows a 6 mm space to slide the backing material into place on the door frame. Requirements for proper fit and appearance are; 16 mm minimum overall thickness, 3 mm wide groove between backer portion and overlay portion of panel, finished inside edge and 11 kg maximum weight. See the Wine Storage section of the Sub-Zero Design Guide for additional panel information. Glass Gasket 11 mm Diameter 6 mm Diameter Illus. 8 MODEL ICB430 INSTALLATION INSTRUCTIONS IMPORTANT NOTE: The size of the overlay panel is critical. It must fit over the door frame. To install overlay panels, first remove the magnet backed trim molding using a piece of tape to pull it away from the frame and expose the frame screws. The molding will bend at the center so that you can remove it. Remove the frame by removing the five screws holding it in place. The door channel is now ready to accept the overlay panel. Slide the panel into the frame on the door. With the panel in position, replace the frame end. Be sure the panel is inserted completely into the channel for proper fit and alignment. Next, replace the trim molding by inserting the top, then the bottom into the frame channel. Release the middle and set the magnets. Install the #8 x 16 mm screws through the back of the glass door frame into the door panel. IMPORTANT NOTE: Install screws in all the mounting holes in the door frame. The nature of the door panel with a narrow outer rim and no connecting center member requires the support provided by the glass door. After the door panel installation is complete, apply the cover patches or plugs provided over the holes on the inside surface of the door. The cover patches or plugs are part of the insulation system on the door of the Wine Storage unit. Be sure to cover all the holes in the door that were used. A solid panel must not be installed on a glass door unit, as this may cause moisture to form behind the panel. OVERLAY GRILLE PANEL MODEL ICB430 If you have not already removed the inner and outer grille frame for moving the unit, remove the inner grille panel assembly, see Grille Removal on page 26. Remove the top two corner screws and pull away the top frame. Slide the panel into position in the grille frame. If you are using a grille panel 6 mm or thinner, you will need to install a filler. Reattach the top frame by reinstalling the two top corner screws. Install the inner grille panel assembly onto the unit. MODEL ICB430 INSTALLATION INSTRUCTIONS MODEL ICB430 SIDE PANEL INSTALLATION If you’re installing a Model ICB430 with side panels, check with your installer or use one of the following Side Panel Installation Options. Drill three holes equidistant in a vertical section of the aluminum frame, and install pan head screws. Do not drill through model and serial number plate. Anchor the side panel with decorative screws or finishing nails from a local hardware store. Do not use adhesives. Refer to illustration 9 below. The dimensions given in the Side Panel Installation Options are for typical wood side panels. If a 6 mm thick or less panel is used and inserted into the return channel extrusion, then a 616 mm wide panel is necessary. In this application, the panel must be notched for the grille and other brackets or screws that are in the return channel. Toe kick cut-outs will be necessary for all side panel applications. Refer to illustration 10 below. IMPORTANT NOTE: The use of side panels may change the width of your rough opening. IMPORTANT NOTE: The overall height on the side panel will vary with the height of the grille being used. Make sure you know your finished height before cutting any panels. SIDE PANEL INSTALLATION OPTIONS 616 mm FRAME 6 mm THICK SIDE PANEL FITTED IN TO UNIT FRAME 3 mm THICK BATTENS DOOR PAN HEAD SCREW SIDE OF SUB-ZERO UNIT 6 mm SIDE PANEL MATERIAL 610 mm FRAME 6 mm THICK BATTENS DOOR PAN HEAD SCREW SIDE OF SUB-ZERO UNIT 6 mm SIDE PANEL MATERIAL 6 mm THICK SIDE PANEL FITTED UP TO UNIT FRAME 3 mm THICK BACK-UP 610 mm FRAME 10 mm THICK SIDE PANEL FITTED UP TO UNIT FRAME 3 mm THICK BATTENS DOOR PAN HEAD SCREW SIDE OF SUB-ZERO UNIT 10 mm SIDE PANEL MATERIAL 610 mm FRAME 13 mm THICK SIDE PANEL FITTED UP TO UNIT FRAME 3 mm ROUT DOOR PAN HEAD SCREW SIDE OF SUB-ZER...

Эта инструкция также подходит к моделям:
Диспенсеры - ICB424 (5.66 mb)
Диспенсеры - ICB424FS (5.66 mb)
Диспенсеры - ICB427 (5.66 mb)
Диспенсеры - ICB427R (5.66 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории