Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Sub-Zero, модель ICB427

Производитель: Sub-Zero
Размер: 5.66 mb
Название файла:
Язык инструкции:itenesfrde
Перейти к скачиванию



Фрагмент инструкции


Plug the power supply cord into the 10 amp grounded electrical outlet. With power applied to the appliance, check for lighting and cooling before going any further. Once you are satisfied that the unit is operating properly, shut off power to the electrical outlet at the circuit breaker and proceed. Shut off the power to the electrical outlet. If a home alarm system is to be used with the Wine Storage unit, the lead wires should be threaded into the compressor compartment before you position the unit. See Other Wiring Connections on page 18 for the location of these lead wires. After the unit is in position, the alarm wiring can be completed from the front. Pre-level the Wine Storage unit before rolling into position. This is to allow the unit to engage the anti-tip bracket properly. Roll the unit into position, making sure the anti-tip bracket is engaged properly. Screw the front leveling legs out approximately 5 mm to make any future adjustments easier. IMPORTANT NOTE: When the Wine Storage unit is installed, the anti-tip bracket will be positioned just below the engaging bracket on the unit. It is not necessary to raise the unit up so that it locks into the anti-tip bracket, but the unit must be in alignment with the anti-tip bracket. IMPORTANT NOTE: The floor under the Wine Storage unit must be at the same level as the surrounding finished floor to allow for removal of the unit for servicing. MODELS ICB427 AND ICB427R INSTALLATION LEVEL THE UNIT Level the unit by turning the front leveling legs clockwise to raise the unit, or counterclockwise to lower it. To assist you in adjusting the front leveling legs up or down, use a standard screwdriver blade and place it in the front leveling leg as shown in illustration 4 below. The rear leveling legs are adjusted from the front of the base by turning the Phillips head screw. Refer to illustration 5. IMPORTANT NOTE: The rear leveling legs will only move 2 mm for every 18 revolutions on the Phillips head screw. Do not over torque. Use the lowest torque setting on any power screwdriver. Do not turn the rear leveling legs by hand. Damage will occur if you turn these legs. To reduce the possibility of the unit tipping forward, the front leveling legs must be in contact with the floor. MOLDING INSTALLATION MODELS ICB427 ICB427R The decorative white molding strips for the side and top of Models ICB427 and ICB427R can be snapped into place. The top molding piece must be installed before the side molding can be attached. For installation of the top molding, refer to illustration 6 below. Refer to illustration 7 for side molding installation. For installations where units are side by side, see Finished Wood Side Panels on page 23. Top Molding Illus. 4 Illus. 5 Illus. 6 Illus. 7 MODELS ICB427 AND ICB427R INSTALLATION MODELS ICB427 ICB427R OPTIONAL COMPONENTS Optional installation components are available through your Sub-Zero dealer. You can also visit our website at subzero.com. OTHER WIRING CONNECTIONS Before the kickplate/grille is installed, all necessary wiring connections in the compressor compartment should be completed. If the dual installation heater kit (#7007529) is used with Model ICB427 or ICB427R, the power supply leads should be connected according to instructions included with the kit. If a home alarm system is to be installed on the Wine Storage unit, the connections should be made using the logic supplied with the alarm specifications. See illustration 8 below for the appliance lead locations, and refer to the following for color codes: Normally open contacts – white with red stripe wire Normally closed contacts – white with blue stripe wire Common – gray with white stripe wire Use the 6 mm spade terminals or wire nuts provided to make the proper wiring connections. IMPORTANT NOTE: If you are not responsible for alarm system connection, this information should be supplied to the home security system contractor. The alarm circuit in the unit is intended as a low-voltage, low-current device only. It should not be used to switch line power. Any unused terminals should be completely insulated and all wires should be secured away from conductive or moving components. Home Alarm Connections Illus. 8 MODELS ICB427 AND ICB427R INSTALLATION KICKPLATE/GRILLE INSTALLATION Once the unit is leveled and wiring connections made, the kickplate/grille can be installed. IMPORTANT NOTE: The kickplate/grille must be removed for servicing. The floor cannot interfere with removal. The louvered section of the kickplate/grille must not be covered so as to prevent air circulation. For Models ICB427 and ICB427R, there is some adjustment to the mounting assembly so that the kickplate/grille can fit flush with the surrounding area. Refer to illustration 9 below. IMPORTANT NOTE: The unit must be allowed to have ventilation through the fins of the kick- plate/grille. You may cover the solid area, but do not block the fins. For Model ICB427R, the lower drawer panel may hang in front ...

Эта инструкция также подходит к моделям:
Диспенсеры - ICB424 (5.66 mb)
Диспенсеры - ICB424FS (5.66 mb)
Диспенсеры - ICB427R (5.66 mb)
Диспенсеры - ICB430 (5.66 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории