You must securely fasten the panels to adjacent cabinets and floor. Panels should be fastened to the floor and walls using ‘L’ brackets (hardware not provided). To help you move the unit into place, rout out an area in the floor so the ‘L’ bracket will sit flush with the floor level. Brackets and screws are provided for mounting the unit to adjoining cabinets and side panels. Each unit has four side-mounting clips on each side. IMPORTANT NOTE: For installations where you are not attaching to a side wall, or you are installing two Model ICB427, ICB427R or Integrated units together, you must remove the side-mounting clips before moving the unit into position. After removing the clips, replace the screws into the appliance. A dual installation heater kit (#7007529) is necessary for anchoring two Model ICB427, ICB427R or Integrated units together. Contact your Sub-Zero dealer for details. LOCK INSTALLATION For Models ICB427 and ICB427R, the accessory lock is attached to the decorative door panel through a field-drilled hole in the panel. The catch should be installed on the top of appliance cabinet before the unit was moved into position. Installation instructions are included with the lock kit. IMPORTANT NOTE: For accessory stainless steel panels requiring a lock, panels must be ordered with the lock mounting hole pre- drilled. 90-DEGREE DOOR STOP Models ICB427 and ICB427R have a 90-degree door stop built into the hinge system. Use the blade edge of a standard screwdriver and rotate the brass cam in the center portion of the hinge until you reach the stop. You must make this adjustment to both the bottom and top hinge. Refer to illustration 15 below. COMPLETING THE INSTALLATION IMPORTANT NOTE: When you have completed the installation of the Model ICB427 or ICB427R Wine Storage unit, refer to pages 34–35 for the Installation Checklist and Service Information. MODELS ICB427 ICB427R OPTIONAL COMPONENTS Optional installation components are available through your Sub-Zero dealer. You can also visit our website at subzero.com. Illus. 15 MODEL ICB430 INSTALLATION INSTRUCTIONS MODEL MODEL ICB430 INSTALLATION ICB430 INSTALLATION SPECIFICATIONS 1918 mm 178 mm 152 mm 749 mm ROUGH OPENING WIDTH 610 mm ROUGH OPENING DEPTH E LOCATE ELECTRICAL WITHIN SHADED AREA ANTI-TIP BLOCK FRONT VIEW TOP VIEW 2127 mm ROUGH OPENING HEIGHT TO FINISHED FLOORING WITH STANDARD 279 mm GRILLE 2108 mm MIN HEIGHT REQUIRED (LEVELERS IN) SITE PREPARATION Make sure that the finished rough opening where the Wine Storage unit is to be installed is properly prepared. Refer to the Installation Specifications illustration for rough opening dimensions, door swing clearance and electrical placement for Model ICB430. If you are installing two Model ICB430 units side by side, or a Model ICB430 and a Built-In model, a separating filler strip is recommended. Add the filler strip width to the finished rough opening dimension. Complete the installation with the Anchoring Kit (part #4200900), see page 33. IMPORTANT NOTE: To operate properly, the door must open a minimum of 90 degrees. Use a minimum 76 mm filler strip in corner installations to assure a 90-degree door opening. Allow enough clearance in front of the unit for full door swing. IMPORTANT NOTE: Make sure the floor under the unit is level with the surrounding finished floor. Do not load wine into the Wine Storage unit until the installation is complete. 90° 130° MAXIMUM DOOR SWING 1270 mm DOOR CLEARANCE 838 mm DOOR CLEARANCE 765 mm 765 mm 606 mm BEHIND FRAME NOTE: Door swing clearances are based on stainless steel door and handle dimensions. MODEL ICB430 INSTALLATION INSTRUCTIONS ELECTRICAL REQUIREMENTS A 220-240 V AC, 50/60 Hz, 10 amp circuit breaker and electrical supply are required. A separate circuit, servicing only this appliance, is required. The power supply cord has a grounding plug, which must be plugged into a mating ground ing- type wall recep tacle. Follow all National Electrical codes and local codes and ordinances when installing the receptacle. For location of the electrical supply, refer to the Installation Specifications illustration. IMPORTANT NOTE: A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. Do not use an extension cord. Electrical ground is required on this appliance. HOME ALARM SYSTEM If a home alarm system is to be used, refer to Home Alarm Connections on page 28. In addition to operating power, the installer may also be required to supply a home automation system lead to the unit. This is for a low- voltage, low-current signal similar to door and window sensor signals. Common, normally open and normally closed contact configurations are provided. Three 6 mm female spade connectors are located in the compressor compartment and are accessible behind the grille on Model ICB430. A minimum of 914 mm of lead wire should be provided for each contact, exiting the back wall near the electrical outlet. UNPACKING AND MOVING MODEL ICB...

Эта инструкция также подходит к моделям:
Диспенсеры - ICB424 (5.66 mb)
Диспенсеры - ICB424FS (5.66 mb)
Диспенсеры - ICB427 (5.66 mb)
Диспенсеры - ICB430 (5.66 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории