The appliance operation light A will flash every 4 seconds. For long periods When you do not expect to use the boiler for a long period: 1 Switch the electricity supply off. 2 Shut off the gas supply cock and the valves for the water circuits fitted under the boiler. 3 If necessary, empty the water circuits. FROST PROTECTION This appliance is provided with a built in anti---freeze system that operates the boiler when the temperature is below 5 uC Therefore, when the boiler is not lit and used in

Скачали: 48   Размер: 188 kb   Производитель: IDEAL INDUSTRIES  
Категория: Водонагреватели
@name

appliance No. 47- ---348- ---38 mini HE C28 G.C. appliance No. 47- ---348- ---39 Destination countries: GB, IE INTRODUCTION mini HE are wall mounted, room sealed, condensing, low water content combination gas boilers featuring full sequence automatic spark ignition and fan assisted combustion. SAFETY Current Gas Safety (Installation & Use) Regulationsorrules in force In your own interest, and thatof safety, it is the law that this boiler must be installed by a CORGI registered installer or in IE

Скачали: 17   Размер: 195 kb   Производитель: IDEAL INDUSTRIES  
Категория: Водонагреватели
@name

Check that the system water water pressure gauge G reads at least 0,5 bar. Check the lock---out signal lamp E. If it is illuminated press the boiler reset button D to restart the ignition sequence. Hot water but no heating Check that the programmer and room thermostat (if fitted) are both calling for heat. Heating but no hot water Check that cold water flows out of the taps at a minimum rate of 3.5 litres per minute (or 1 pint in 10 seconds or less). If not, look for stop valves not fully open.

Скачали: 3   Размер: 195 kb   Производитель: IDEAL INDUSTRIES  
Категория: Водонагреватели
@name

· Check the room thermostat is set at the required temperature – Test the room thermostat by turning fully up – If this does not respond contact your installer · Check the radiator temperature control (C) is set at the winter setting for central heating. The nature of all combination boilers is to heat up water directly from the incoming mains water supply directly through the boiler to supply domestic hot water at the stated flow rates, (as shown in the boiler installation instructions), to ach

Скачали: 1   Размер: 195 kb   Производитель: IDEAL INDUSTRIES  
Категория: Водонагреватели
@name

F If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes. F Under no circumstances should any of the sealed components on this appliance be used incorrectly or tampered with. F If it is known or suspected that a fault exist on the boiler then it MUST NOT BE USED until the fault has been corrected by a CORGI registered installer or in IE a competent person. MINIMUM CLEARANCES Clearances of 200 mm (7 7/8“) above and below, 25 mm (1“) at left, 50 mm (

Скачали: 0   Размер: 195 kb   Производитель: IDEAL INDUSTRIES  
Категория: Водонагреватели
@name

Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers (button) Mini BOILER CONTROLS Mini C24 G.C. appliance No. 47- ---348- ---18 Mini C28 G.C. appliance No. 47- --- 348- --- 19 Mini C32 G.C. appliance No. 47- --- 348- --- 25A Mini S24 G.C. appliance No. 41- --- 392- --- 98 Mini S28 G.C. appliance No. 41- --- 392- --- 99 Destination countries: GB, IE INTRODUCTION Mini are wall mounted, room sealed, non condensing boilers featuring full sequence automatic s

Скачали: 4   Размер: 195 kb   Производитель: IDEAL INDUSTRIES  
Категория: Водонагреватели
@name

Benchmark has been introduced to improve the standards of installation and commissioning of central heating systems in the UK and to encourage the regular servicing of all central heating systems to ensure safety and efficiency. THE LOG BOOK SHOULD BE COMPLETED AFTER EACH SERVICE AND KEPT WITH THESE INSTRUCTIONS (button) CONTROL OF CH TEMPERATURE The output temperature of CH water is adjustable from a minimum of about 38°C to a maximum of about 85°C by turning the knob C. Approx CH flow temperat

Скачали: 8   Размер: 1 mb   Производитель: IDEAL INDUSTRIES  
Категория: Водонагреватели
@name

Planar • 62 Models • Heights 300, 400, 500, 600mm • Lengths 400 - 2000mm • Output 235 - 3268 watts • Types K1 & K2 • 6 Tappings - Pre-piped TBSE • Flat fronted design Options See page 31 29 data & dimensions data & dimensions Height Length Elements Plane Plane (mm) (mm) Single Double Data & Dimensions - Plane 440 500 6 382 673 440 600 6 458 808 440 700 6 535 942 440 800 6 611 1077 440 900 6 688 1211 440 1000 6 764 1346 440 1100 6 840 1481 440 1200 6 917 1615 440 1400 6 1070 1884 440 1600 6 1222

Скачали: 6   Размер: 1 mb   Производитель: IDEAL INDUSTRIES  
Категория: Водонагреватели
@name

External sequencer control kit . Module blanking off pack . 14 Super Plus 200 - 600kW • Horizontal assembly • High efficiency 85% (gross) • Low NOx emissions (class 5) • 100kW Modules • Ultra compact • Sequence controlled • Easy to install and service Model 200/S 300/3 300/3A 400/4 400/4A 500/5 600/6 Modules 2 3 3 4 4 5 6 Output (kW) 200 300 300 400 400 500 600 Height 1800 1900 1900 1900 1900 1900 1900 Width 910 1510 2115 1510 2115 2115 2115 Depth 990 990 990 990 990 990 990 Flow/Return Connecti

Скачали: 7   Размер: 1 mb   Производитель: IDEAL INDUSTRIES  
Категория: Водонагреватели
@name

De Luxe control panel (High / Low operation) . Flue gas thermometer . GT Condenser . 18 Viceroy GT 300 - 780kW • Natural gas, oil fired or dual fuel • High efficiency • Minimal emissions • 3 pass heat exchanger • Compact size • Meets Building Regulations 2006 (Part L2) Model GT8 GT9 GT10 GT11 GT12 GT13 GT14 Sections 8 9 10 11 12 13 14 Output (kW) 390 450 540 600 670 720 780 Height 1695 Width 1000 Depth 1505 1665 1825 1985 2145 2305 2465 Flow/Return Connections (mm) 75 75 75 100 100 100 100 Flue