|
Фрагмент инструкции
Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers (button) Mini BOILER CONTROLS Mini C24 G.C. appliance No. 47- ---348- ---18 Mini C28 G.C. appliance No. 47- --- 348- --- 19 Mini C32 G.C. appliance No. 47- --- 348- --- 25A Mini S24 G.C. appliance No. 41- --- 392- --- 98 Mini S28 G.C. appliance No. 41- --- 392- --- 99 Destination countries: GB, IE INTRODUCTION Mini are wall mounted, room sealed, non condensing boilers featuring full sequence automatic spark ignition and fan assisted combustion. Mini C24, Mini C28 and Mini C32 are low water content combination gas boilers. Mini S24 and Mini S28 are low water content system gas boilers. SAFETY Current Gas Safety (Installation & Use) Regulations or rules in force In your own interest, and that of safety, it is the law that this boiler must be installed by CORGI registered installer or in IE a competent person, in accordance with the above regulations. It is essential that the instructions in this booklet are strictly followed, for safe and economical operation of the boiler. ELECTRICITY SUPPLY The appliance must be efficiently earthed. Supply 230 V 50 Hz. The fusing should be 3 A. Connection must be made in a way that allows complete isolation of the electrical supply, such as a double pole switch, having a 3 mm (1/8”) contact separation in both poles, or a plug and socket serving only the boiler and system controls. The means of isolation must be accessible to the user after installation. IMPORTANT NOTES F This appliance must not be operated without the casing correctly fitted and forming an adequate seal. F If the boiler is installed in a compartment then the compartment MUST NOT be used for storage purposes. F Under no circumstances should any of the sealed components on this appliance be used incorrectly or tampered with. F If it is known or suspected that a fault exist on the boiler then it MUST NOT BE USED until the fault has been corrected by a CORGI registered installer or in IE a competent person. MINIMUM CLEARANCES Clearances of 200 mm (7 7/8“) above and below, 25 mm (1“) at left, 50 mm (2“) at right and 450 mm (17 3/4“) at the front of the boiler case must be allowed for servicing. After installation the following clearances are allowable during use, providing the encasing parts are removeable for servicing: The bottom clearance can be reduced to 20mm (3/4”). The front clearance can be reduced to 50mm (2”). A A B C D E F G Mini C24 Mini C28 Mini C32 BCDE FG Mini S24 Mini S28 Appliance On lamp Domestic hot water temperature control Main switch and radiator temperature control Boiler reset button Lock---out signal lamp Programmer (optional) System pressure and temperature gauge TO LIGHT THE BOILER 1 Check that the valves located in the lower part of the boiler are open. 2 Switch the the electricity supply on. The appliance On lamp A will flash every 4 seconds (stand---by condition). For combination models Mini C24, Mini C28 and Mini C32 3 If the bo...
Эта инструкция также подходит к моделям:Водонагреватели - MINI C24 (194.78 kb)
Водонагреватели - MINI C28 (194.78 kb)
Водонагреватели - MINI S28 (194.78 kb)
Водонагреватели - MINI C32 (194.78 kb)