Войти:
Оценок - 5, средний балл: 3.6 ( )

Инструкция по эксплуатации American, модель ATO-705A-P

Производитель: American
Размер: 500.65 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Pump / Aquastat Control Wire Cold Water Supply Line Building Hot Water Supply Line Gas Supply Expansion Tank Drawing Number:WH-6-B Domestic Hot Water - Backup Storage6 Tankless Water HeatersPreferred Piping Installation Drawing Date: February 27, 2008 This is not an engineering drawing; it notas a replacement for professional engineering This drawing is not intended to describe It is up to thecontractor or engineer to determine andconfiguration of the particular The drawing doesnot imply compliance with It is theresponsibility of the engineer isin accordance with Confer with local buildingofficials before installation. Key Pressure Relief Valve 3/ 4" Ball Valve3/ 4" UnionCheck Valve S Pressure RegulatorCirculating PumpSolenoid Valve Boiler Drain Valve 31 TanklessWater Heater TanklessWater Heater TanklessWater Heater TanklessWater Heater TanklessWater Heater TanklessWater Heater Set water heaters @ 20°Fabove storage tank Aquastat Storage Tank(No Burner orHeating Element)SubmersibleAquastat(set @ 20°F belowTankless TemperatureSetting) TanklessEquipment List QTY Tankless Commercial 6 Water HeatersReference the section on Pump Sizing for Storage Tank Application. BuildingCirculation Pump Pump / Aquastat Control Wire Cold Water Supply Line Building Hot Water Supply Line Gas Supply Expansion Tank Expansion Tank Building Hot Water Return Line Drawing Number: WH-6-B-R Domestic Hot Water - Backup Storage / Circulation6 Tankless Water HeatersPreferred Piping Installation Drawing Date: February 27, 2008 This is not an engineering drawing; it notas a replacement for professional engineering This drawing is not intended to describe It is up to thecontractor or engineer to determine andconfiguration of the particular The drawing doesnot imply compliance with It is theresponsibility of the engineer isin accordance with Confer with local buildingofficials before installation. Key Pressure Relief Valve 3/ 4" Ball Valve3/ 4" UnionCheck Valve S Pressure RegulatorCirculating PumpSolenoid Valve Boiler Drain Valve 32 G as S upply V1 V3 V2 V4 H1 H2 H3 Circulating Pump C old W ate r Lin eHot Wa ter Line In- l ni eF ilter Flush Procedure1. Disconnect electrical power to the water heater. and V4). 3. Connect pump outlet hose (H1) to the cold water line at service valve V2.4. Connect drain hose (H3) to service valve V1.5. Pour approximately 4 gallons of virgin, food grade, white vinegar or citric acid into pail. 6. Place the drain hose (H3) and the hose (H2) to the pump inlet into the cleaning solution. 7. Open both service valves ( V1 and V2) on the hot water and cold water lines. 8. Operate the pump and allow the cleaning solution to circulate through the water heater for at least 45 minutes. 10. Rinse the cleaning solution from the water heater by: a. remove the free end of the drain hose (H3) from the pail11. Disconnect all hoses. 13. Restore electrical power to the water heater. Drawing Number:M-1-F 1 Tankless Water Heater Maintenance - Scale Flush Procedure Drawing D...

Эта инструкция также подходит к моделям:
Водонагреватели - 186965-000 (500.65 kb)
Водонагреватели - AGT-705-NE (500.65 kb)
Водонагреватели - AGT-705-NI (500.65 kb)
Водонагреватели - AGT-705-PE (500.65 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории