Фрагмент инструкции


(2.615kPa). Propane/LP gas will have a manifold pressure approximately 10.0" w.c. (2.49kPa) at the pressure regulator outlet with the inlet pressure to the pressure regulator from a minimum of 11.0" w.c. (2.739kPa) for the purpose of input adjustment to a maximum of 13.0" w.c. (3.237kPa). A test gage connection is located downstream of the gas appliance pressure regulator for measuring gas pressure. The connection is a 1/8 inch (3mm) N.P.T. plugged tapping. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter Tubing, Type L Outside Diameter Nat. L.P. Nat. L.P. 0-10 feet 0-3 meters 1/2” 12.7mm 3/8” 9.5mm 1/2” 12.7mm 3/8” 9.5mm 10-40 feet 4-12 meters 1/2” 12.7mm 1/2” 12.7mm 5/8” 15.9mm 1/2” 12.7mm 40-100 feet 13-30 meters 1/2” 12.7mm 1/2” 12.7mm 3/4” 19mm 1/2” 12.7mm 100-150 feet 31-46 meters 3/4” 19mm 1/2” 12.7mm 7/8” 22.2mm 3/4” 19mm FLOORCEILINGSIDEWALL24”MIN(610mm) 14”MIN(356mm) 6”MIN(152mm) 6”MIN(152mm) 2”MIN(51mm) CEILINGWINDOWSILLORSHELF24”MIN(610mm) 14”MIN(356mm) 12”MAX(305mm) 0”(0mm)CLEARANCETOREARWALLSIDEVIEW2”MIN(51mm) FLOOR Figure 5 (SR-10) Figure 6 (SR-10) SR-18 CLEARANCES FLOOR2”MIN(51mm) 6”(152mm) MIN6”(152mm) MINSIDEWALLCEILING36”(914mm)MIN When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches (152mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the appliance (shelves, window sills, etc.) 36 inches (914mm). Floor (top surface of carpeting, tile, etc.) 2 inches (51mm). Provide adequate clearances around air openings. Adequate accessibility clearances for purposes of servicing and proper operation must be provided. Figure 7 (SR-18) On Solid Wall 1. After locating mounting holes, attach (4) #10 x 1" (25mm) screws provided into the wall. Do not completely tighten screwheads to the wall, leave a 1/8" (3mm) gap between screwheads and wall. 2. Mount heater onto the (4) screwheads and complete tightening screwheads into the wall. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield. b. When replacing reflector, be sure the top lip of reflector goes in front of the heat shield. 3. Connect the gas line. On Sheet Rock Wall 1. After locating mounting holes, drill (4) 5/16" (8mm) diameter holes into the wall. 2. Insert (4) plastic expansion anchors provided into the holes. 3. Tighten (4) #10 x 1" (25mm) screws provided into the plastic expansion anchors. Do not completely tighten screwheads to the plastic expansion anchors, leave a 1/8" (3mm) gap between screwheads and plastic expansion anchors. 4. Mount heater onto the (4) screwheads and complete tightening the screwheads to the plastic expansion anchors. Attention! Use the following steps to properly align the upper louver and the reflector with the heat shield. a. When replacing upper louver, be sure the bottom lip of upper louver goes behind the heat shield. b. When replacing reflector, be sure the top lip of reflector goes in front of the heat shield. 5. Connect the gas line. 18” (457mm) 14” (356mm) 13/32” (28mm) 187/8” (479mm) OUTLINEOFOUTERCASING22” (559mm) 21/32”(52mm)41/32”MIN(102mm) FLOOR2”MIN(51mm) MOUNTINGHOLELOCATIONSVIEWEDFROMFRONTOFHEATER Figure 11 (SR-18) 241/8” (613mm) 201/8” (511mm) 2” (51) 2” (51) 13/32” (28mm) 187/8” (479mm) 41/32” (102mm) MIN21/32”(52mm) 22” (559mm) 2”(51mm)MIN Figure 12 (SR-30) Figure 13 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; Do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above. 2. Turn off all electric pow...

Эта инструкция также подходит к моделям:
Водонагреватели - SR-18-3 (2.81 mb)
Водонагреватели - SR-10-3 (2.81 mb)
Водонагреватели - SR-30-3 (2.81 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории