Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Wolf Appliance Company, модель L402212

Производитель: Wolf Appliance Company
Размер: 193.97 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


1) Remove the filters of the hood liner by pushing each filter up at the angle it is placed in, then rotate the bottom of the filter down. Refer to the illustration below. Remove the center filter first. Gloves should be worn when handling filters. 2) The hood liner is shipped with the transition attached upside down in the top of the hood liner. It must be removed and reinstalled in the proper position. Remove the blower mounting plate from the hood liner by removing four nuts from inside the liner. Detach the transition by removing four shipping screws. Reinstall the blower mounting plate back onto the liner and reattach the transition onto the top of the blower mounting plate. Refer to the illustration on page 11. 3) Attach the transition to existing ductwork with sheet metal screws and duct sealing tape. 4) If you are installing an in-line or remote blower, drill a 7/8" (22) hole through the wood framing for the conduit. Refer to in-line and remote blowers on pages 12–13. FILTER GREASE CUP SIDE VIEW SPRING Filterremoval. Pro Hood Liner Installation Hood Liner Installation Due to the weight of the hood, be sure to have adequate assistance for installation. The filters must be removed from the hood liner prior to installation. Refer to hood liner preparation on the previous page. Position the hood liner in the desired location on the wall. Install #10 x 2" (59) screws through the mounting holes on the back plate. Verify that the screws engage the wall studs or blocking. If additional support is required for the hood liner, drill supplementary mounting holes in the back plate and use these holes to attach the hood liner to wall framing. Hood Wiring Connections BLOWER WIRING Before making electrical connections, make sure the electrical power is turned off at the service panel. IMPORTANT NOTE: Refer to specific installation instruc- tions provided with each blower assembly for additional mounting and wiring instructions. 1) Remove the hood electrical box cover from the back of the hood liner. Run Romex® wire from the service panel to the hood installation location. Insert the Romex® wire through the holes in the back of the hood liner to the electrical box. Refer to the illustration below for the location of wiring. 2) Using the wire connectors provided, connect black wire to power supply black wire, white wire to power supply white wire and green wire to green wire or bare wire. 3) Place all wiring connections inside the electrical box and reinstall the cover. Make sure all wires are secure and that no wires are pinched between the cover and electrical box. 17/8" (48) 31/2" (89) 121/2" (318) Location of hood wiring. Pro Hood Liner Installation Blower Assemblies Pro ventilation hoods are shipped without the blower assembly. Internal, in-line and remote blowers are avail- able through your authorized Wolf dealer. For local dealer information, visit the find a showroom section of our website, wolfappliance.com. The blower will vary in size and is d...

Эта инструкция также подходит к моделям:
Вентиляторы - L342212 (193.97 kb)
Вентиляторы - L582212 (193.97 kb)
Вентиляторы - L462212 (193.97 kb)
Вентиляторы - L522212 (193.97 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории