Фрагмент инструкции


Fix the wall brackets. 2. Fix the canopy hood. 3. Connect the hood to the mains supply ensuring that the canopy is functioning correctly. 4. Select the type of installation, ie. ducting or recirculation. 5. Fix the chimney stack. NOTE: The hood is more efficient in the exhaust mode, therefore, this position should be selected during the warmer months of the year when no heating is being used. When the room is being heated, if the recycle position is selected heat will not be wasted. Installing your Cooker Hood WALL FIXINGS: Lower Fixings 1. Draw a vertical line on the wall, from the centre of the cooking appliance, up to the ceiling. Check the line is vertical using a spirit level. 2. Put the template provided on the wall and drill two o12mm holes (Fig.1 2) 3. Fit two hooks in the drilled holes (Fig.1 3). Upper Fixing Bracket 1. Draw a horizontal line through the vertical line, 15mm from the ceiling. Check the line is level using a spirit level. 2. Place the chimney support bracket (Fig.1 10) over the line, ensuring the bracket is level. Mark the positions for the fixing screws. 3. Drill the two holes for the wall bracket, insert the wall plugs and fit the bracket using the screws provided. Fig.1 FIXING THE CANOPY HOOD: 1. Remove the metal filters (Fig.1 4). 2. Hang the hood canopy on the hooks (Fig.1 3). Adjust the position of the hood using the two screws at the bottom of the hooks (Fig.1 5). 3. Whilst the hood is positioned, mark the two holes (Fig.1 6). 4. Remove the hood and drill the two holes. Insert the wall plugs (Fig.1 7). Return the hood to the hooks and fix with the two screws. Before fitting the chimney to the canopy, make the electrical connection as described in the section ‘Electrical Requirements’ (page 2). Once the electrical connection has been established, test the worktop illumination and the three speed fan. Installing your Cooker Hood RECIRCULATION: The chimney hood is supplied specified for installation in the extraction mode. To convert to recirculation it will be necessary to obtain the optional pack of two carbon filters. In the recirculation mode, contaminated air enters the chimney hood and passes through the grease filters and carbon filters and then out into the kitchen through two grilles, at either side of the lower chimney. To convert the chimney hood to recirculation proceed as follows: 1. To fit the carbon filters, open the metal grease filters. Place one filter over the inlet grille at either end of the fan housing and twist into position (Fig.2). Fig.2 Fig.3 NOTE: The two venting grilles must not be fitted into the chimney stack until the chimney stack has been installed onto the wall above the canopy. 2. Fit the recirculation spigot over the round outlet on top of the canopy, whilst pressing down on the spigot (Fig.3). EXTRACTION: Ducting Fitting: The chimney hood can be ducted to the outside, using either rigid or flexible ducting of 100mm, 120mm or 150mm. the choice of ducting is left to the discretion of the installer, however, the best performance will be obtained by using 150mm of rigid ducting. Where flexible ducting is fitted it should not be turned through very tight bends as this could impair the performance of the hood. The ducting must be manufactured from fire retardant material conforming to the relevant British Standard or DIN 4102-B1. Where the 125mm ducting is used, it will be necessary to install the reduction flange and 125 . 125mm ducting collar over the air outlet in the top of the canopy (Fig.4). Fig.4 The installer should provide suitable ducting and sealing tape for the installation. The (optional) carbon filter is not required when the hood is installed in the ducting mode. Installing your Cooker Hood Fitting the Chimney Stack: To fit the upper chimney section, first expand the chimnet slightly to allow it to be fitted over the wall brackets. Then secure the upper section using the four self tapping screws provided. The lower chimney section should be located following instructions on page 6, ensuring that the lugs in the base of the chimney are seated into the two recesses on either side of the canopy (Fig.5). Fig.5 ATTENTION: Should the lower chimney section subsequently be removed, the two securing lugs in the top canopy must be released. Once the chimney stack has been installed, fit the two venting grilles into the apertures located on either side of the lower chimney stack. The grilles are marked with two arrows and should be fitted with one arrow pointing upwards and the other towards the front. When used in the recirculation mode, ensure the grilles are properly secured to the recirculation spigot. Operating your Cooker Hood The Controls Make sure that the Cooker Hood is wired in and the power supply is switched on. The Cooker Hood functions are controlled by 5 push buttons, located on the front face of the hood. To obtain the best performance it is advisable to switch on the chimney hood a few minutes before you start cooking and leave ...

Эта инструкция также подходит к моделям:
Вентиляторы - CRC90 (92.55 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории