Фрагмент инструкции


WARNING: Make sure main power is turned off.! 2. Fan sounds 1. Blades not attached to fan. 1. Attach blades to fan before operating. noisy. 2. Screws securing fan blade flanges to motor are loose. 3. Wire connectors inside switch housing rattling. 4. Screws holding blades to flanges are loose. 5. Loose screws in motor housing. 2. Check to make sure the screws which attach the blade flanges to the motor are tight. 3. Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing. WARNING: Make sure main power is turned off. 4. Tighten screws securely. 5. Check to make sure all screws in motor housing are snug (not over-tight) ! 3. Fan wobbles excessively. 1. Setscrew in motor coupling is not tightened securely. 2. Setscrew in the hanger ball/downrod assembly is loose. 3. Screws securing fan blade flanges to motor are loose. 4. Fan blade flanges not seated properly. 5. Hanger bracket and/or ceiling outlet box is not securely fastened 6. Fan blades out of balance. 1. Raise coupling cover and tighten setscrew securely. 2. Tighten the setscrew in the hanger ball/downrod assembly. 3. Check to be sure screws which attach the fan blade flanges to the motor are tight. 4. Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor. If flanges are seated incorrectly, loosen the flange screws and retighten according to Step 12 and Figure 6. 5. Tighten the hanger bracket screws to the outlet box, and/or secure outlet box. 6. Interchanging an adjacent (side-by-side) blade pair can redistribute the weight and result in smoother operation. Or use supplied balancing kit to balance blades. 10 Repair Parts 28 29 6 10 9 30 12 23 11 3 2 1 8 4 5 7 21 7 6 24 25 FAN BLADE (Order Separately) 13 14 15 33 32 26 20 27 18 19 17 19 16 22 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • PART NUMBER • NAME OF ITEM • PART DESCRIPTION • MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing. For repair parts, phone 1-800-654-3545. 31 11 Repair Parts Listing Key No. Description Part Numbers Model No. CF2400AB00 Model No. CF2400BC00 Model No. CF2400BZH00 Model No. CF2400ORB00 Model No. CF2400PW00 Model No. CF2400SCK00 Model No. CF2400WB00 * 1 2 3 Hanger Pack, Consisting of: Hanger Bracket Hanger Ball Downrod 761655-3 — — — 761655-24 — — — 761655-57 — — — 761655-32 — — — 761655-22 — — — 761655-31 — — — 761655-20 — — — * 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Parts Bag, Containing: Wire Connector (4) Setscrew Wrench, 5/32” Knurled Knob (4) Lockwasher (4) Threaded Stud, 1-1/4” (2) Threaded Stud, 1” (2) Hairpin Pin Clevis Pin Setscrew, 5/16-18 x 1/4” Screw, Phillips Pan Head, #10-32 x 3/8” (16) Washer, Flat, #10 (16) Screw, Oval Head, #10-32 x 5/8” (11) Screw, Pan Head, #8-32 x 3/8” (3) Pendant, Fan Pull Chain Pendant, Uplight Pull Switch Coupling (2) 762548 — — — — — — — — — — — — — — — — 762548 — — — — — — — — — — — — — — — — 762548 — — — — — — — — — — — — — — — — 762548 — — — — — — — — — — — — — — — — 762548 — — — — — — — — — — — — — — — — 762548 — — — — — — — — — — — — — — — — 762548 — — — — — — — — — — — — — — — — 20 Cover, Ceiling 762556-5 762556-4 762556-13 762556-12 762556-8 762556-11 762556-1 21 Cover, Motor 761621-3 761621-23 761621-27 761621-25 761621-21 761621-24 761621-17 22 Capacitor, Aux. 10 uF 762242 762242 762242 762242 762242 762242 762242 23 Motor 762508 762508 762508 762508 762508 762508 762508 24 Hub, Motor 760601 760601 760601 760601 760601 760601 760601 25 Flange Set, Blade (full set for one fan) 762540-5 762540-4 762540-13 762540-12 762540-8 762540-11 762540-1 26 Housing Assembly, Switch 762542 762542 762542 762542 762542 762542 762542 27 Cover, Switch Housing 762544-5 762544-4 762544-13 762544-12 762544-8 762544-11 762544-1 28 Plate, Cover 762546-5 762546-4 762546-13 762546-12 762546-8 762546-11 762546-1 29 Nut, Finial 762547-5 762547-4 762547-13 762547-12 762547-8 762547-11 762547-1 30 Switch Assembly, Reversing 762627 762627 762627 762627 762627 762627 762627 31 Harness Assembly, Uplight 762625 762625 762625 762625 762625 762625 762625 32 T8 Candelabra Bulb, 25-watt (4) — — — — — — — 33 Lead Assembly, Uplight (used only for remote control operation) 761790 761790 761790 761790 761790 761790 761790 — Owner's Manual BP7278 BP7278 BP7278 BP7278 BP7278 BP7278 BP7278 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO8100 W. Florissant . St. Louis, MN 63135 Part No. F40BP72780000 Printed in China 05/06 Form No. BP7278 ...

Эта инструкция также подходит к моделям:
Вентиляторы - CF2400AB00 (248.25 kb)
Вентиляторы - CF24000SCK00 (248.25 kb)
Вентиляторы - CF2400BC00 (248.25 kb)
Вентиляторы - CF2400BZH00 (248.25 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории