Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации Air King, модель COOKER HOOD DF 6160

Производитель: Air King
Размер: 613.74 kb
Название файла: 4bc890a8-5f65-8034-1df6-e5ec6e218fb8.pdf
Язык инструкции:enfrdenl
Перейти к скачиванию



Фрагмент инструкции


Then fix the hood with the 4 or 6 x O 4 mm screws supplied. • Refit the grease filters. Push-in the visor. Fig. 11 • If the cupboard is deeper than 300 mm, cover the gap between the hood and the wall with a finishing strip (special accessory). To install it, proceed as follows: Measure the wall distance and apply the covenng strip over the necessary width (wall distance plus 5 to 8 mm), kinking the covering strip at the appropriate notches and tearing off the surplus material (removing the protective foil). Then fasten the strip to the bottom part of the hood with three clips (special accessories). Apply pressure. Fig. 12. Fig. 12 Fitting the charcoal filter for recirculation version If the extractor hood is installed as a return air appliance (Recirculation version - air outlet above the wall unit), the charcoal filter (available from your local Service Force Centre) must be fitted before the grease filters are fitted. Installation sequence: 1. Insert the holding frame for the charcoal filter in the shaft of the hood with the 2 lugs facing upwards and then clip into the lower holes. 2. Fix the holding frame on the lower part of the housing of the hood with the 2 screws supplied. Fig. 13. 3. Fit the charcoal filter (see paragraph “Charcoal filter”) 4. Refit the grease filters. Push-in the visor. Fig. 13 Removing the hood from the wall unit If, for technical reasons (extraction version/recirculation version conversion) the extractor hood has to be removed from the wall unit, proceed as follows: • Fully withdraw the visor and remove the grease filter. • Loosen the 4 or 6 mounting screws of the hood (wall unit mounting). • To loosen both mounting claws (installation aids), place a max 3 mm dia. Phillips screw-driver in the spring opening and simultaneously press the springs inwards (towards the appliance housing). Fig. 14. Fig. 14 Important: Hold the hood firmly! Adjusting the extractor part (E - Fig. 1) - Fig. 15 On wall units with a body depth of 275 mm to 335 mm, the visor depth can be adjusted as follows: • Remove both grease filters. • Loosen the screws on both end-stop brackets and set the visor depth (min. 275 mm, max. 335 mm). • Refit the screws. • Refit the grease filters. Fig. 15 Installing the front panel (see also “Special accessories”) • Remove first the rear then the front grease filters. • Remove the internal cover pressing both unlocking devices (press and pull). Fig. 16. Fig. 16 • Predrill the front panel as per template and fix it to the visor with 3 screws. Fig. 17-18. Fig. 18Fig. 17 • Clip the Internal cover back in and insert both grease filters (first the front one and then the rear one). 77 78 79 AEG Hausgerate GmbH Postfach 1036 D-90327 Nurnberg © Copyright by AEG LI1SGD Ed. 02/03 ...

Эта инструкция также подходит к моделям:
Вентиляторы - COOKER HOOD CHDF 6260 (613.74 kb)
Вентиляторы - COOKER HOOD DF 6160 (613.74 kb)
Вентиляторы - COOKER HOOD DF 6160 (613.74 kb)
Вентиляторы - COOKER HOOD DF 6160 (613.74 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории