|
Фрагмент инструкции
The switch must be accessible at all times. The following is valid in the United Kingdom only: -the wire which is coloured green and yellow must be connected to the terminal which is marked with the letter E or by the earth symbol ( ), or coloured green or green and yellow; -the wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black, - the wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. Installation Preparing the wall unit - Extractor version • The hood is supplied as an extractor unit. Before installing the hood, drill a hole in the roof of the wall unit (see item. 5). This hole is to allow passage of the outlet pipe and the power cable, and to facilitate servicing. • The wall unit must have a minimum body depth (without door) of 300 mm with recessed Fig. 5 light screen and min. 370 mm with flush-mounted light screen. The unobstructed internal height must be at least 370 mm. Preparing the wall unit - Filter version (DF 6160) • Before installation of the hood in the wall unit, a 115x115 mm hole for the deflector should be cut in the ceiling of the wall unit. Fig. 6-7. • Depending on the wall unit height, you need for return air operation a pipe union or additionally a non-flammable length of pipe (O 100/115/ 120 mm) as far as the ceiling of the wall unit. Fig. 6 Fig. 7 72 Outlet hole - Only for models DF 6260, DF 6260-ml/1 and CHDF 6260 (extractor-filter version) • When used as an extractor unit, the hood must be fitted with a 150mm diameter hose. Only for model DF 6260 - DF 6260-ml/1: Should there already be a pipe of diameter 125 mm that ducts to the outside through the walls or roof, it is possible to use the 150/125 mm reduction flange provided. In this case the hood will be slightly more noisy. Fix the flange on the hood outlet hole, using 2 screws. Fig. 8a. Filter version only • Fix the deflector to the flange. Fig. 8b. Outlet hole - Only for model DF 6160(extractor-filter version) • When used as an extractor unit, the hood must be fitted with a 120mm diameter hose. • The dimensions and position of the air outlet are given in figure 9. • Using the adapter, O100, O110 and O125 mm exhausting pipes can be used. O 125 mm exhausting hose: insert the adapter on the flange and remove, using a proper tool, the upper unused O 100 and O 110 mm rings of the adapter. O 110 mm exhausting pipe: same procedure, but removing the O 100 mm ring only. O 100 mm exhausting pipe: apply the adapter on the flange. Fig. 8a Fig. 8b Fig. 9 Fig. 10 A Spice rack • If a spice rack is to be incorporated in front of the hood, a minimum distance of 5 mm must be provided between the front edge of the fume extractor hood and the spice rack wall (this air gap being necessary for air circulation). • The upper part of the spice rack rear wall should be detachable (access for exhaust air hose or adjustment of furniture housing). Installing the extractor h...
Эта инструкция также подходит к моделям:Вентиляторы - COOKER HOOD CHDF 6260 (613.74 kb)
Вентиляторы - COOKER HOOD DF 6160 (613.74 kb)
Вентиляторы - COOKER HOOD DF 6160 (613.74 kb)
Вентиляторы - COOKER HOOD DF 6160 (613.74 kb)