Инструкция по эксплуатации Vermont Casting, модель LHERDV20

Производитель: Vermont Casting
Размер: 1.69 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


11.0" W.C. Maximum Inlet Pressure 14.0" W.C. 14.0" W.C. Manifold Pressure 3.5" W.C. 10.0" W.C. Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the unit and replace any part of the control which has been under water. These gas inserts are approved for installation in solid fuel burning masonry or zero clearance fireplaces. High Elevations Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level. For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1/NFPA 54 and/or local codes having jurisdiction. In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m). LHECDV20 / LHERDV20 LHEDV30 / LHERDV30 Certified To ANSI Z 21.88-2005 / CSA 2.33-2005 Vented Gas Fireplace Heaters Preparation Before beginning, remove glass door and logs from unit. Also check to make sure there is no hidden damage to the unit. Take a minute and plan out the gas,venting and electrical route. It is best to start with the gas line first followed by the chimney liner. (Refer to Page 9) Gas Line Installation When purging the gas line, the front glass must be removed. If gas piping from the source to the heater location has not been accomplished, install the required pipe. Consult local plumbing code to assure proper pipe size. The gas pipeline can be brought in through the rear or the base of the heater. NOTE: The gas line connection can be made of either properly tinned 3/8" copper tubing, 1/2" rigid pipe or an approved flex connector then reduced to 3/8" to the heater. Some municipalities have additional local codes, it is always best to consult your local authority and the CSA- B149.1 installation code. U.S. Installations consult the current National Fuel Gas Code, ANSI Z223.1/NFPA 54. Always check for gas leaks with a mild soap and water solution. Do not use an open flame for leak testing. The gas control is equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control. When using copper or flex connector, use only approved fittings. Always provide a union when using black iron pipe so the gas line can be easily disconnected for burner or fan servicing. See gas specifications for pressure details and ratings. NOTE: If flex connector is used, it must be kept inside of the heater. 1/2" Gas Supply 1/2" x 3/8" Shut Off Valve 3/8" Nipple 3/8" Union FP297 Fig. 4 Typical gas supply installation. 3/8" Nip- ple 1/2" Gas Supply 1/2" x 3/8" Shut Off Valve 3/8" Nipple 3/8" Union FP297 Fig. 4 Typical gas supply installation. 3/8" Nip- ple Gas Supply Pressures This heater must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure equal to or less than 1/2 psig (3.45kPa). The heater and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45kPa). Fan Kit 115 volt, 60 Hz. 56w (Model FK24) NOTE: The LHERDV20 and LHERDV30 are not designed for a fan kit. The fan kit includes the following: fan, temperature sensor, speed control and a 6 ft. cord. The following explains how to start and set the fan for automatic operation. 1. Plug in the electrical cord. 2. Start gas fire - see lighting procedures. 3. Turn on fan speed control. 4. Wait until the unit has warmed up sufficiently to activate the temperature sensor, approx. 5-10 minutes. 5. Once fan starts, adjust speed control to desired fan speed. The fan will now automatically come on every time the fireplace is in operation. Should the fan not be needed simply turn off the speed control. The appliance, when installed must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code. U.S. Installations, follow local codes and the National Electrical Code, ANSI/NFPA No. 70. Should this fan require servicing, the power supply must be disconnected. For rewiring of any replacement components refer to Figure 6. LHEDV Series Direct Vent Insert Fan Removal Instructions 1. Turn off gas and electricity. 2. Remove the front glass. 3. Remove the logs. CAUTION: Logs may be hot! 4. For Model LHECDV20: remove burner assembly and bracket rear log. For Model LHECDV30: remove bracket rear log and cover fan. 5. Remove the fan mounting nuts (2 nuts). (Fig. 5) 6. Slip off the electrical connector at the motor. 7. Lift out the fan. 8. To reinstall reverse procedure. Thermal Sensor is Attached to Burner Base Fan is Installed at the Back of the Air Intake Box Fan Speed Control/Junction Box Screw Stud Screw Stud FP1252 Fig. 5 Fan location. Fan Temperature Sensor Speed Control Black White Ground FP394 F...

Эта инструкция также подходит к моделям:
Вентиляторы - LHECDV30 (1.69 mb)
Вентиляторы - LHERDV30 (1.69 mb)
Вентиляторы - LHECDV20 (1.69 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории