Please ensure that your room is well ventilated - open all windows. It is recommended that you burn your fireplace for at least ten (10) hours the first time you use it. If optional fan kit has been installed, place fan in the "OFF" position during this time. Locating Your Gas Fireplace Insert with Zero Clearance Kit CDBEAFXXXFP1249a Fig. 1 Locating unit with zero clearance kit. A) Flat on wall B) Cross corner C) Island D) *Room divider E) *Flat on wall corner F) Chase installation NOTE: (Fig. 1) * When you install your fireplace in (D) Room divider or (E) Flat on wall corner positions, a minimum of 6 (X) inches (153mm) clearance must be maintained from the perpendicular wall and the outer edge of the trim. Insert Applications Before installing the gas fireplace insert, consideration must be given to the functioning needs of the fireplace. The size of the fireplace cavity (min. 25..."W x 17..."H x 13..." D (641 x 438 x 343 mm) for the LHECDV20 and LHERDV20, 28..."W x 21"H x 15..."D (730 x 533 x 394 mm) for LHECDV30 and LHERDV30), the design of the chimney for effective venting should be determined. The availability of the gas supply as well as electricity for the insert fan must be confirmed. Your Direct Vent Insert unit is designed to be vented vertically with a minimum height of 12' (4 m). LHEDV Series Direct Vent Insert Fireplace & Trim Dimensions Q V 1 = 2 = 3 = 4 = 5 = N O P . 1" M E F U S R T Q - Fireplace opening height R - Fireplace opening width S - Depth of insert T - Firebox width at insert depth(S) LHESSB LHESLB/LHEABSL/LHESLGA LHECSLB/LHECSLMB/LHECSLSA LHEACNSS LHETCK Minimum Fireplace Insert Opening U - Firebox depth at insert back height (V) V - Insert back height NOTE: LHESLGA is only available for Model LHEC30 and LHER30 Insulation Gas Inlet KnockoutAir Circulating Channel Zero Clearance Kit . . B A C D G B 3" (75mm) Dia. H I JA K 4894 LHEDV SPEC 4/03 L T R I M LHECDV20 LHERDV20 LHECDV30 LHERDV30 A-1 20..." (530 mm) 20..." (530 mm) 26..." (680 mm) 26..." (680 mm) B-1 30..." (781 mm) 30..." (781 mm) 38..." (972 mm) 38..." (972 mm) A-2 24..." (616 mm) 24..." (616 mm) 28...." (716 mm) 28...." (716 mm) B-2 37..." (952 mm) 37..." (952 mm) 41" (1042 mm) 41" (1042 mm) A-3 24..." (616 mm) 24..." (616 mm) 28..." (717 mm) 28..." (717 mm) B-3 38..." (968 mm) 38..." (968 mm) 41....." (1059 mm) 41....." (1059 mm) A-4 20..." (527 mm) 20..." (527 mm) 24..." (629 mm 24..." (629 mm) B-4 30..." (784 mm) 30..." (784 mm) 34...." (875 mm) 34...." (875 mm) A-5 28" (711 mm) 28" (711 mm) 32..." (819 mm) 32..." (819 mm) B-5 45" (1143 mm) 45" (1143 mm) 49" (1245 mm) 49" (1245 mm) F I R E P L A C E C 25..." (651 mm) 25..." (651 mm) 29...." (741 mm) 29...." (741 mm) D 17" (432 mm) 17" (432 mm) 17..." (448 mm) 16..." (425 mm) E 35" (889 mm) 35" (889 mm) 35" (889 mm) 35" (889 mm) F 26..." (676 mm) 26..." (676 mm) 26..." (676 mm) 26..." (676 mm) G 13..." (343 mm) 13..." (343mm) 15..." (394 mm) 16..." (419 mm) H 17" (432 mm) 17" (432 mm) 20..." (521 mm) 20..." (521 mm) I 18" (457 mm) 18" (457 mm) 21..." (546 mm) 21..." (546 mm) J 19..." (486 mm) 19..." (486 mm) 22..." (575 mm) 22..." (575 mm) K 15" (381 mm) 15" (381 mm) 17" (432 mm) 18" (457 mm) L 10..." (264mm) 10..." (273 mm) 11..." (298 mm) 12..." (324 mm) M 8..." (216 mm) 8..." (216 mm) 8..." (216 mm) 8..." (216 mm) N 37..." (946mm) 37..." (946 mm) 37..." (946 mm) 37..." (946 mm) O 19..." (486 mm) 19..." (486 mm) 19..." (486 mm) 19..." (486 mm) P 27..." (692 mm) 27..." (692 mm) 27..." (692 mm) 27..." (692 mm) 4 M I N I M U M O P E N I N G Q 17..." (444 mm) 17..." (444 mm) 21" (533 mm) 21" (533 mm) R 25..." (641 mm) 25..." (641 mm) 28..." (730 mm) 28..." (730 mm) S 13..." (343 mm) 13..." (343 mm) 15..." (394 mm) 16..." (419 mm) T 17" (432 mm) 17" (432 mm) 17..." (451 mm) 17..." (451 mm) U 13..." (349 mm) 13..." (349 mm) 15..." (400 mm) 16..." (419 mm) V 18" (457mm) 18" (457 mm) 21...." (541 mm) 10004894 21...." (541 mm) LHEDV Series Direct Vent Insert Mantels When the unit is installed into a woodburning fireplace, the minimum distance the mantel can be placed above the fireplace is governed by local building codes applicable to woodburning fireplaces. Consult local authorities having jurisdiction for these clearances. For applications requiring the use of a Zero Clearance Kit, the minimum height a mantel can be installed above the fireplace is 24" (610 mm) from the top of the upper louvres. The maximum mantel depth is 8" (203 mm). (Fig. 2) The underside of the mantel will become warm. Use only finishes which are heat resistant and do not discolor. 24" Min. (610mm) FP1325 Fig. 2 Minimum mantel height above fireplace. Framing & Finishing For Zero Clearance Kit applications, it is important to determine the finished facing material before beginning to frame. This will allow for the thickness of the finishing material between the frame and the fireplace trim. Similarly, consideration must be given to the 1" inch depth of the air inlet channel sitting on the fireplace base...

Эта инструкция также подходит к моделям:
Вентиляторы - LHERDV20 (1.69 mb)
Вентиляторы - LHERDV30 (1.69 mb)
Вентиляторы - LHECDV20 (1.69 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории