The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree. In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. “AUTO” is displayed next to the flame and fan icons. Fan Override During Auto Mode If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key. Pushing a key once will change the fan level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the fan icon. Change Between F/C Temperature Units Push the up and down arrow keys simultaneously for at least 3 seconds to toggle between Fahrenheit and Celsius units. Disable Thermostat Function To disable the thermostat function in the AUTO mode, push the time and down keys simultaneously for at least 3 seconds. To Change Batteries 1. Remove cover on the backside of the transmitter. Install 3 AAA batteries as shown and reattach cover. 2. Once steps 1-3 in OPERATION are completed, receiver/valve and transmitter are now ready. Press any button on transmitter for recognition process to occur between the receiver/valve and transmitter. 3. Use functions as described in TRANSMITTER section. Troubleshooting 1. Locate LED light on valve. 2. LED will blink after every valid command received by the transmitter; this is not an error. 3. Failure codes may occur anytime after pilot burner is lit. 4. Sequence is failure code followed by light not blinking for 30 seconds. 5. In the event of multiple failure codes, next failure code follows previous failure code by approximately 3 seconds. FA N Antenna Red White Red White Valve (Bottom View) Fan Pilot Assembly FP1038 Fig. 55 Comfort Valve wiring diagram. White Dots If an Error Code 3 is observed while performing the testing, complete the following: 1. Make sure the spade connectors are pushed all the way on. If rhe Error Code 3 is still showing, then go to the next step. 2. Switch the front two thermopile leads with the back two. Be sure the white lead is connected to the spade with the white dot next to it. If the Error Code 3 is still showing, replace the thermopiles. If an Error Code 8 is observed while performing the testing, complete the following: 1. Confirm the valve is not in REMOTE mode. • If the valve is producing Error Code 8 and in REMOTE mode, the valve is defective and should be replaced. • If the valve is in LOCAL mode and producing Error Code 8, then go to the next step. 2. Slide the Remote/Local switch to REMOTE and teach the valve a transmitter (see item 6, page 1). The Error Code will clear itself after approximately 1.5 minutes and return to normal operation. LED Count Service Action 8 Replace valve 7 Confirm stepper motor connection exists 5 Confirm fan connection exists and works 4 Confirm gas type; jumper in place 3 Replace thermopiles 2 Turn fan ON NOTE: Some keys are not active. Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters Comfort Valve System Control Sequence Of Operation With Transmitter Light pilot burner Set manual switch to local or remote Release pilotstat knob. Turn pilotstat knob from PILOT to ON. Did the LED stop blinking? Review LED failure analysis. Five minute wait period Cycle switch once and leave in remote. Press any key on transmitter for recognition operation. Choose Manual or Remote path. Set switch to manual or remote. Yes Yes If manual switch is set to LOCAL, did main burner light and fan turn on? Turn pilotstat knob to PILOT to turn off main burner. Turn pilotstat knob to OFF to turn valve completely off. Yes Local Path On Path Move switch from local to remote. Press any key on transmitter. Move switch back to local. If the manual switch is set to REMOTE, press the mode button to display “ON”.does transmitter control the main burner and fan? Yes Does transmitter change levels of flame height, fan speed? Yes Move switch from manual to remote. Press any key on transmitter. No Set levels of flame height and fan to “0” to shut off main burner and fan. Turn pilotstat knob to OFF to turn valve completely off. Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters Auto Path If the manual switch is set to REMOTE, Move switch from press the mode button LOCAL to REMOTE. to display AUTO on the Fuel Conversion Instructions WARNING! This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. T...

Эта инструкция также подходит к моделям:
Вентиляторы - 3926 (882.07 kb)
Вентиляторы - 3930 (882.07 kb)
Вентиляторы - 3936 (882.07 kb)
Вентиляторы - 3960 (882.07 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории