|
Фрагмент инструкции
The heater is approved to be vented to the outdoors through any solid-fuel fireplace chimney that has been constructed or installed in accordance with the national, Provincial/State and local building codes and is constructed of noncombustible materials. For Venting Requirements, refer to Page 10. Refer to Venting Components on Page 12. Fireplace Vent Termination Clearances Observe the chimney-top vent termination clearances specified in the instructions provided with those components. Some considerations are: • Obstructions or impediments to venting. • Nearby combustible materials that could come into contact with combustion exhaust gases. • Other nearby openings (within 9” (230mm) through which exhaust gas could reenter the building. • All vegetation within 36” (914mm) that may interfere with the draft. NOTE: The collar extending down from the Termination base is the air intake collar. Use the flex vent liner, marked with a blue line, to connect between this collar and the lowerflue collar on the Transition Connector. Also make sure the other flex vent liner is attached to the upper Transition Connector collar and the Rain Cap. (Fig. 35) 1. Clean the top of the chimney as needed, to ensure a good seal between it and the vent termination. 2. Slide the insulation sleeves provided in the termination kit over the two 3" flex liners (to be attached to the 3" flue collar and cap of the termination assembly). 3. Feed 3" flex vent from the bottom of the termination assembly up through the 4" sleeve. Apply high- temperature sealant to the rain cap collar, and slide the flex vent over the end of the rain cap collar, fastening with the clamp provided. 4. Slide the flex liner back through the 4" sleeve until the rain cap/collar engages over the sleeve. Attach the cap to the sleeve with three sheet metal screws provided in the kit. 5. Apply high-temperature sealant over the air intake collar, and attach the intake flex vent (blue) with a clamp. Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters 6. Apply high-temperature sealant to the top of the chimney. Feed the two liners down through the chimney flue and damper opening. Fasten the termination assembly to the chimney with the four set screws (C) provided. 7. Trim the flex liners as needed. Each should be only long enough to connect to the Transition Connector. There should be no sag in either flex liner when the stove is in place. 8. Attach the flex liners to the Transition Connector, using high-temperature sealant and clamps as shown in Figure 35. Prop the connector in rough position until the heater is in place in front of it. A B B B D C C B D A B A B C D B A B A D A A = Sealant Locations B = Sheet Metal Screws C = Termination Screws D = Clamps Fireplace Vent System ST395 Fig. 35 Fireplace vent system installation. Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters 25..." (641mm) 24..." (619mm) 15..." (400mm) ST379 Fireplace Installation Requirements - PDV20 Transition Connector 22 ..."(568mm) 18..." (476mm) 24 ..."(619mm) Transition Connector ST380 Fig. 36 PDV20 minimum lintel height for flush or forward placement. 6" (152mm) 22 ..."(568mm) 18..." (476mm) 24 ..."(619mm) * Existing Wood Stove Chimney PIpe Finished Combustible Wall ST713 * Transition pipe must be at least 6” (152mm) from any combustible material. X Existing Vent Pipe Transition Connector Field Fabricated Cover “X” must be 6” (152mm) from any combustible material unless completely covered by field fabricated sheet metal. If 3” vent pipes are covered by sheet metal, the clearance to combustibles may be 2” (51mm). ST715 Fireplace Installations Using Existing Wood Stove Chimneys Fig. 37 PDV20 installations using existing wood stove chimney pipe. Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters 26" (660mm) 16" (406mm) ST379a Transition Connector 26" (660mm) 20..." (521mm) ST380a Transition Connector Fireplace Installation Requirements - SDVR Fig. 38 SDVR minimum lintel height for flush or forward placement. 6" (152mm) 20..." (521mm) 26"(660mm) * Existing Wood Stove Chimney Pipe Finished Combustible Wall ST713a * Transition pipe must be at least 6” (152mm) from any combustible material. X Existing Vent Pipe Transition Connector Field Fabricated Cover ST714 “X” must be 6” (151mm) from any combustible material unless completely covered by field fabricated sheet metal. If 3” vent pipes are covered by sheet metal, the clearance to combustibles may be 2” (51mm). Fireplace Installations Using Existing Wood Stove Chimneys Fig. 39 SDVR installations using existing wood stove chimney pipe. Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters Connect the Gas Supply Line Burner Information Check the rating plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The PDV20 and SDVR may be converted from one gas to another using the appropriate Fuel Conversion Kit listed on Page 41. CAUTION This appliance should only be ...
Эта инструкция также подходит к моделям:Вентиляторы - 3926 (882.07 kb)
Вентиляторы - 3930 (882.07 kb)
Вентиляторы - 3936 (882.07 kb)
Вентиляторы - 3960 (882.07 kb)