TROUBLESHOOTING The cookers may only be opened by authorized service personnel. CAUTION Do not open the cooker, dangerous electric voltage inside. NOTE: Stop any actions if the heating area (Ceran glass) is cracked or broken. The induction cooker must be switched off and disconnected from the electric supply. Don’t touch any parts inside the cooker. TROUBLESHOOTING continued Malfunction With Error Code Number of Flashing Signals (Code) Possible Cause Action To Take By Operator Or Operating Personnel E03 - . . . - . . . Overheated heat sink Let unit cool down Check air filter and air flow Air-cooling system obstructed Verify that air inlet and air outlet are not obstructed with objects Clean air filter E04 - . . . . - . . . . Overheated cooking zone Let unit cool down Check air filter and air flow E06 - . . . . . . - . . . . . . Overheated electronic Let unit cool down Check air filter and air flow Ambient temperature too high (the cooling system is not able to keep the cooker in normal operating conditions 1) Verify that no hot air is sucked in by the fan. Reduce the ambient temperature. The air inlet temperature must be lower than 104°F/40°C E07 - . . . . . . . - . . . . . . . Empty cooking sensing element activated Reset empty cooking protection by switching the unit off E08 - . . . . . . . . - . . . . . . . . Ambient temperature beyond operating range Make sure that the operating conditions (especially the ambient temperature) are kept Error on sensing element Contact service agent Order of error message: The indicator lamp lights up for an interval of 0.6 sec. The number of the following short flashes has to be counted and informs about the kind of error corresponding to the above mentioned code system. The code will repeat until the error is cancelled. 1 The cooling-system (fan) starts to operate when the ambient temperature in the control area exceeds 131°F/55°C. At heat temperatures higher than 158°F /70°C the controller automatically reduces the power to keep the unit in normal operating conditions. The cooker runs in a non continuous mode. This mode can be heard. TROUBLESHOOTING continued Malfunction Without Error Code Fault Possible Cause Action To Take By Operator Or Operating Personnel No heating Operation indicator light is OFF (dark) No mains supply Check the electrical supply (cable plugged onto the wall socket) Check preliminary fuses Control knob is in OFF-position Turn control knob ON Cooker is defective Ask your supplier for repair service Unplug the cooker from the mains supply No heating Operation indicator light is flashing (If an error code is flashing see section “Malfunction with error code”) Pan is too small (bottom diameter less than 4.72” (120mm), only BH/IN and SH/IN) Use a suitable pan Pan is not placed in the center of the heating area (the cooker cannot detect the pan) Move the pan to the center of the heating area Unsuitable pan Choose a pan recommended for induction cooking 1 Cooker defective Ask your supplier for repair service, unplug the cooker from the mains supply Poor heating Operation indicator light is ON (shining) Used pan is not appropriate Use a pan recommended for induction cooking and compare the result with “your” pan Air-cooling system obstructed Verify that air inlet and air outlet are not obstructed with objects Ambient temperature is too high (the cooling system is not able to keep the cooker in normal operating conditions 2) Verify that no hot air is sucked in by the fan. Reduce the ambient temperature. The air inlet temperature must be lower than 104°F /40°C. One phase is missing (only units with three phase supply) Check preliminary fuses Cooker defective Ask your supplier for repair service, unplug the cooker from the electrical supply No reaction to control knob positions Control knob defective Ask your supplier for repair serviced, unplug the cooker from the mains supply Heating cycle switches off and on Within minutes, fan is active Air inlet or outlet obstructed or fan dirty Remove objects from air inlet and air outlet slots, clean the slots Clean fan Heating cycle switches off and on Within minutes, fan is never active Fan defective Fan control defective Ask your supplier for repair service 1 To verify, if the pan is suitable, use a permanent magnet and find out if it sticks on the bottom of the pan. If not, your pan is not suitable for induction cooking. Choose a pan which is recommended for induction cooking. Choose pan material suitable for induction appliances. 2 The cooling-system (fan) starts to operate when the ambient temperature in the control area exceeds 131°F/55°C. At heat temperatures higher than 158°F /70°C the controller automatically reduces the power to keep the unit in normal operating conditions. The cooker runs in a non continuous mode. This mode can be heard. Fault Possible Cause Action To Take By Operator Or Operating Personnel After a long permanent operating time, the heating switches off and on within minutes Coil overheat...

Эта инструкция также подходит к моделям:
Варочные панели - SH/WO/IN 3500 (715.88 kb)
Варочные панели - BH/IN 2500 (715.88 kb)
Варочные панели - SH/IN 3500 (715.88 kb)
Варочные панели - SH/IN 5000 (715.88 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории