Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Garland, модель SH/IN 3500

Производитель: Garland
Размер: 715.88 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


4. The air intake temperature must be under 104°F (40°C). 5. The operating staff has to make sure that installation, support and inspection is done by qualified personnel. INSTALLATION continued Cut Out For Model BH/IN 2500 The size of the cut out in the built-in area must be, 11.41” x 11.41” (290 x 290mm), the depth 7.87” (200mm) and the base at least 13.39” x 11.75” (340 x 273mm). Side View of the right0.06" [1.5mm] air exitair exit4.06" [103mm] VentilatorMains Cableair supply6.73" [171mm] 11.02" [280mm] Ceransurface10.23" [260mm] 10.23" [260mm] 12.20" [310mm] 12.20" [310mm] Front viewConnection clutch for operation devicePlugin clutch for operation device3.07" [84mm] 11.02" [280mm] 5.04" [128mm]7.32" [186mm] Required cutout of the work topmin. 11.42" x 11.42" [290mm x 290mm] Mounting height min. 7.87" [200mm] air supply INSTALLATION continued Cut Out for Models SH/IN 3500 And SH/IN 5000 The size of the cut out in the built-in area must be 13.78” x 13.78” (350 x 350mm), the depth 9.45” (240mm) and the base at least 16.14” x 13.90” ( 410 x 353mm). Side view of the right0.06" [1.5mm] Air exitVentilatorAir SupplyAir exit5.63" [143mm] 12.99" [330mm] 7.20" [183mm] Ceransurface12.60" [320mm] 12.60" [320mm] 15.12" [384mm] 15.12" [384mm] Front viewNet cablePlugin foroperating devicePlug type connectionfor operating device3.86" [98mm] 13.03" [331mm] 7.13" [181mm]8.90" [226mm] Required cutout of the work topmin. 13.78' x 13.78' [350mmx 350mm] Mounting heightmin. 9.45" [240mm] Air supply INSTALLATION continued Cut Out For Models SH/WO/IN 3500, SH/WO/IN 5000 And SH/WO/IN 8000 The size of the cut out for the built in area must be 14.37” x 14.37” (365 x 365mm), the depth 11.81” (300mm) and the base at least 16.14” x 13.90” (410 x 353mm). 11.81” (300MM) WOK-CERAN-BOWLAir supplyAir exit0.06” (1.5mm) 8.46” (5mm) Side view of the rightFront view Net cableAir exit7.20” (183mm) 13.47” (330mm) Ventilator15.12” (384mm) 15.12” (384mm) 9.92” (252mm)16.69” (297mm) 3.86” (98mm)13.03” (331mm) 14.31” (363.5mm) Connection clutchfor operation devicePlug-in clutchfor operation deviceMounting heightmin. 11.81” (300 mm) Air supplyRequired cut-out of the work topmin. 14.49” x 14.49” (368mm x 368mm) INSTALLATION continued Unit Placement After the cut out has been made according to the previous sections, apply silicone to the top of the counter and press the induction unit into the silicone, allowing for a complete water tight seal between the unit and the counter. Make sure the unit is level. Installation of Operating Unit Each unit is supplied with a complete operating unit. In order to fix this unit on the surface of the enclosure, a cut out for the power switch and the LED must considered. The operator control panel has to be fixed vertically on the installation panel. The cable for the power switch and the LED have a length of 39.37” (1000mm). 4.09" [104mm] 4.09" [104mm] 4.72" [120mm] 4.72" [120mm] 0" 0.55"[14mm] 0.75"[19mm] 1.73"[44mm]4.17"[106mm] 4.72"[120mm] 3.66" [93mm] 2.24" [57mm] 3.66"[93mm] 0.08" [2mm] 4.72" [120mm] 4.72" [120mm] 2.36" [60mm] 1.50" [38mm] 1.99" [50.5mm] 0.31" [8mm] 0.31" [8mm] 4x R 0.20"[5mm] 4X counter sunko 0.31"x o 0.18" [o 8mm x o 4.5mm] 4.09" [104mm] 4.09" [104mm] 1.10" [28mm]2X o 0.20"[o 5mm] o 0.40"[o 10.2mm] o 0.33"[o 8.5mm] INSTALLATION continued Figure # 1 Cut Out OpeningLouveredAir ExhaustOpening(By Installer) Aluminum air duct(Max 96" (8')) mounted on collarswith hose clampsRemovable grease ­lter and airintake housing mounted oncabinetFresh Air SupplyAir Intake HousingSee Fig. # 2Sleeve with hose clip: mounted to cabinetSleeve with hose clip: mounted on bottom of unitSilicone Fresh Air Intake Installation The built-in induction units require a cooling air intake to operate effectively. The air intake housing is mounted to the cabinet, and is fitted with a removable stainless steel grease filter that can be cleaned in a dishwasher. Install the air intake housing and connect it to the induction unit with the aluminum air duct. Maximum length of this air inlet is to be 96” (8’). Make sure the cabinet is also equipped with a louvered air exhaust having a size of no less than 30 sq inches (50 sq inches for dual units) for the hot air to escape (by installer). Failure to provide adequate ventilation for the unit will result in the unit overheating, nuisance shut down and potential failure of the unit. (See Figures # 1 & 2) Figure # 2 - Air Intake Housing 9" [288.6 mm] 8 3/16" [208 mm] 11" [279.4mm] 10 3/16" [258.8mm] 5/32" [4mm] FRONT VIEWTOP VIEW4 Holes See Cut out for air intake housing on next page Figure 2 Continued - Cut Out CUTOUT9.125" x 7" [231.8mm x 177.8mm] 4 HOLES Instructions For Assembly: Induction Built-In Units Garland has made enhancements for the installation requirements for the induction cooker built-in models. These changes are designed to provide the installer with greater details for installation. Meeting these requirements will reduce failure due to installation deficiencies NOTE: B...

Эта инструкция также подходит к моделям:
Варочные панели - SH/WO/IN 3500 (715.88 kb)
Варочные панели - BH/IN 2500 (715.88 kb)
Варочные панели - SH/IN 5000 (715.88 kb)
Варочные панели - SH/WO/IN 5000 (715.88 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории