|
Фрагмент инструкции
See gas supply requirements. WARNING BEFORE CONNECT THE APPLIANCE ON THE GAS LINE SUPPLY, ENSURE THAT ITS GAS SET IS APPROPRIATE. THE TYPE OF GAS ADJUSTED AND SHIPPED FROM THE FACTORY IS INDICATED ON THE RATING PLATE LOCATED ON BOTTOM OF BURNER BOX. Cooktop Installed over Oven Installation Only certain specified cooktop and oven models are approved for cooktop over oven installations. Cooktops approved for this type of installation will have an approval label located on the outside of the burner box. If you do not find this label, contact your dealer to confirm that cooktop is approved. The label on the bottom of your cooktop lists the cooktop and oven combinations that are approved for this type of installation. 4 Cooktop & Installation Manual Model COGB ENGLISH 5 Product Dimensions and Cutout Requirements Important Preparation Suggestions 1. Chamfer all exposed edges of decorative laminate to prevent damage from chipping. 2. Radius corners of cutout and file to Insure smooth edges and prevent corner cracking. Recommend 1/4“or 3/8“diameter drill In each corner. 3. Rough edges, inside corners which have not been rounded and forced fits can contribute to cracking of the countertop laminate. This cooktop has been designed with wide tolerances of cut-out to cover possible replacement with other brands. We recommend to that you consider the minimum dimension of cutout size In the case of new Installation. Some cut out sizes for possible replacements: • 28 1/2" (72.4 cm) X 19 15/16" (50.7 cm) • 28 1/2" (72.4 cm) X 19 5/8" (49.8 cm) • 29" (73.7 cm) X 19" (48.3 cm) 001 (76.2 cm) 30" (8 cm) 3-1/8" (53.3 cm) 21" Figure 1. Product dimensions LENGTH OF CUT MIN: 28 1/2" (72.4 cm) MAX: 29" (73.6 cm) WIDTH OF CUT MIN: 19" (48.3 cm) MAX: 19-5/8" (49.8 cm) 1-1/2" (3.8 cm) MIN CLEARANCE FROM EDGE OF CUTOUT AND FRONT EDGE OF COUNTERTOP 2-1/2" (6.35 cm) SEE NOTE* 002 Figure 2. Coutout dimensions Cooktop & Installation Manual Model COGB ENGLISH Mobile Home Installation The installation of this cooktop must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety; Title 24 HUD part 280); or when such standard is not applicable, the Standard for Manufactured Home Installations (Manufactured Home Sites, Communities and Setups), ANSI A225.1 - latest edition, or with local codes. In Canada, the installation of this cooktop must conform with the current standards CAN/CSA-Z240 - latest edition, or with local codes. 13" (33 cm) MAX DEPTH WALL COVERING CABINETS, OF UNPROTECTED AND COUNTERTOP MUST OVERHEAD CABINETS WITHSTAND HEAT UP TO 200 °F MIN 30" (76.2 cm) 30" (76.2 cm) MIN (see NOTE) CLEARANCE FROM COUNTERTOP TO UNPROTECTED OVERHEAD SURFACE 18" (45.7 cm) MIN HEIGHT FROM COUNTERTOP TO NEAREST CABINET ON EITHER SIDE OF UNIT 003 5" (12.7 cm) MIN CLEARANCE FROM CUTOUT TO SIDE WALL ON THE LEFT AND RIGHT OF THE UNIT Figure 3. Cutout requirements NOTE: • If cabinet has a dr...
Эта инструкция также подходит к моделям:Варочные панели - COGB 33060/L/BL (2.84 mb)
Варочные панели - COGB 33060/L/BL (2.84 mb)
Варочные панели - COGB 33061/L/WH (2.84 mb)
Варочные панели - COGB 33062/L/SS (2.84 mb)