Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Honeywell, модель 47200A

Производитель: Honeywell
Размер: 308.35 kb
Название файла: 47200.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


By saving energy, your thermostat will pay for itself during its first season of use. Thank you for buying a Hunter product! Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, call Hunter Technical Support at 1-866-268-1936 from 8am to 5pm Central Time. Before starting, remove the mylar label from the LCD display. IMPORTANT INFORMATION 1. This thermostat is designed to work on the following systems: Gas - Standing Pilot Single-Stage Heat Pumps - with no auxiliary heat Gas - Electronic Ignition Electric Furnace Gas - Fired Boilers Electric Air Conditioning Gas - Milivolt Systems Oil - Fired Boilers This thermostat will NOT control single-stage or multi-stage Oil - Fired Furnace heat pumps or 110/220 V baseboard electric heating systems. 2. Temperature Range This thermostat can be programmed between 7°C and 35°C (45°F and 95°F). It will display room temperatures from 0°C and 37°C (30°F to 99°F). “HI” will be displayed if the temperature is higher than 37°C (99°F), and “LO” will be displayed if the temperature is lower than 0°C (30°F). This thermostat will automatically cut-off in Heat mode if the temperature rises above 35°C (95°F), and automatically cut-off in Cool mode if the temperature drops below 4°C (40°F). 3. Compressor Protection This thermostat provides a 3.5 minute delay after shutting off the cooling system before it can be restarted. This feature will prevent damage to your compressor caused by rapid cycling. It does not prevent a rapid compressor restart due to short power outages. 4. Battery Warning Two fresh AA alkaline batteries should provide well over one year of service. However, when the batteries become drained, the Low Battery Indicator will flash on the display. When this message occurs, install new alkaline batteries. You have approximately 1 minute to change the batteries and keep thermostat’s clock and program settings. Once the batteries have become too low to ensure proper operation, your system will be turned Off, and the display will be cleared except for flashing Low Battery Indicator on the LCD display. CAUTION: When only the battery icon flashes on the display, the thermostat is shut down, and your system will no longer operate. In this condition, there is no temperature control of your dwelling. NOTE: If you plan to be away from the premises over 30 days, we recommend that you replace the old batteries with new alkaline batteries prior to leaving. FEATURES Front Door: Covers keys when not used for neat Day / Time Key: Used for entering the Clock appearance. Open by lifting from the bottom setting mode. Use with the Up and Down keys day/timereset systemheat cooloff program filterhold/return fan autoon M AM 4 TEMP to set the time and day. LCD Display: Shows Time, Day, Temperature, Up and Down Keys: Keys for Program Number, and changing the Temperature other feature information setting. Also used for increasing as required. and decreasing selections in the Time, Program, and Span Low Battery Indicator: functions. Flashes when batteries need to be replaced. Program Key: Used for entering and modifying Programs. Use System Switch: with the Up and Down keys to Selector switch for set times and temperatures. Heat, Cool, and Off Press when in Clock setting mode to select between 12 and Fan Switch: Fan 24 hour clock modes. switch for Automatic or Continuous fan Filter Key: Resets filter change operation. counter to zero. Battery Compartment: Hold / Return Key: Used for Front access allows setting a permanent (vacation) easy insertion of two hold, and for returning to the AA 1.5V batteries. normal display from Day & Time setting, Programming, or Span setting modes. Reset: Press with a paper clip to reset the Battery Release Lever: thermostat and return to power-up settings. Push to pop batteries loose. ENERGY STAR® PARTNER As an ENERGY STAR® Partner, Hunter Fan Co. has determined that this programmable thermostat meets the ENERGY STAR® guidelines for energy efficiency. INSTALLATION What You Need This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your thermostat, you should have the following tools and materials. ¦ Slotted Screwdriver(s) ¦ Small Philips screwdriver ¦ Hammer ¦ Electric drill and 3/16” bit ¦ Two 1.5 V (AA) size alkaline batteries Remove Old Thermostat CAUTION: Do not remove any wiring from existing thermostat before reading the instructions carefully. Wires must be labeled prior to removal. ¦ IMPORTANT! Turn off the power to the furnace at the main power panel or at the furnace. ¦ Remove existing thermostat cover and thermostat. See Figure 1. Some thermostats will have screws or other locking devices that must first be removed. Once the wall mounting plate is exposed, look for wires. If wires are not visible, they may be connected to the back of the wallplate. Again, look for screws, tabs, etc. Some models have doors that open to expose wires and mounti...

Эта инструкция также подходит к моделям:
Термостаты - 47200A (308.35 kb)
Термостаты - 47200A (308.35 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории