Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации ACR Electronics, модель Nauticast Y1-03-0203

Производитель: ACR Electronics
Размер: 3.99 mb
Название файла:
Язык инструкции:ende
Перейти к скачиванию



Фрагмент инструкции


Alarms are displayed in the Alarm Inbox (see Menu 5: Transponder Configuration, Submenu 3: Alarm Settings) and on the ECDIS screen. Note: It is highly recommended to enable the Alarm Function. © (ms) (mö) (m?) (m8) A Dynamic Keys: Alarm Settings [M5] [Save] Save Alarm Settings [M8] [Back] Return to Submenu Configuration [M6] [Change] Configure Alarm Generation (on/off) d) Interrogation Settings This screen allows settings for modes of response to Long Range Interrogation Requests (LRI). It is possible to set the AIS station to respond automatically or manually to LR Interrogations, and determine which vessel data may be interrogated. It is further possible to reply to incoming LRI’s. Long Range Interrogation Settings: © © © (M3) (mÎ) (Menu) N 1o19' E 0o13' |1>0.1C |2>1.30|3>1 8 0nm ******** Interrogation Settings *** ***** on/off auto/manu LR-Interrogation: [*]/[ ] [*]/ ] Data for Interrogation: Name,Call,IMO [*] Cargo *] Length,Beam,Type [*] Draught *] POS [*] PoB *] SOG [*] Dest,ETA *] COG [*] Date,Time *] | Save | Change | All On | Back (ms) (mö) (w) (m8) A User Manual 53 Y1-03-0203 Rev.L Dynamic Keys: LR Interrogation Settings [M5] [Save] Save LRI Settings [Up] / [Down] Select Data Field for Configuration [M6] [Change] Enable or Disable selected Field for Interrogation [Enter] Select Data Field for Configuration [M7] [All On] Configure All Data for Interrogation [Left] / [Right] Enable or Disable selected Field for Interrogation [M8] [Back] Return to Menu Configuration Replying to a Long Range Interrogation Request: The arrival of an LRI is shown in the Navigation Screen (top right hand corner: * 1L) The detailed LRI is automatically stored in Menu 1:Messages, Submenu: 6 Inbox LRI, where the request can be read and replied to. © ® © (M3) (wm) (Menu) LAT:N 1o20.261'ExtSOG:34.6kn * 1L LON:E 0o13.705'IntCOG:173.0o 13:37:34 IntGPS: 3D ExtHDT:222o Reg6 /B 001/021..ShipName....RNG.BRG..S0G..C0G.. 1>D0REEN-----------> N/A 120 22.2 301.5 2>FINE EAGLE------->0.00 N/A 13.1 359.9 3>SYLVAEPSIL0N----->0.10 23 32.1 203.2 4>ESS0T0KY0-------->0.43 99 10.0 120.3 5>0LYMPIAHIGHWAY FE>0.59 342 21.2 50.0 6>SANEI------------>0.80 272 32.1 270.1 7>KAT00------------>1.00 321 21.2 200.8 8>0LYMPIA PALACE--->1.34 277 [BASESTAT] 9>MINIL0G---------->1.96 201 21.7 102.2 10>ALIBRAHIMYA----->2.66 340 22.1 30.3 11>TITANIC--------->2.75 121 N/A N/A 12>BWRTZ123-------->3.36 66 24.1 2.9> (ms) (m6) (m) (ms) A User Manual 54 Y1-03-0203 Rev.L Dynamic Keys: Replying to a LR Interrogation [M5] [OK] Notifies User of current interrogation [M8] [Back] Return to Vessel Listing [M7] [Reply] Display Message Editor for LRI Reply Sensor Settings The screen provides the means to switch the sensor speeds. It allows the user to change sensor interfaces from IEC61162-1 to IEC61162-2 settings. The data input fields are fitted with default values. The [Up], [Down] buttons are used for menu navigation, the [Left] or [Right] buttons for default data input. Sensor Software Configuration (Service Password protected) This is new in software version 2.0.1.x. The NAUTICAST offers the following configuration options: Set up data speed 4800/9600/38400 baud. Monitor the connected sensor inputs for each sensor channel. Verify and edit the Sensor Configuration on the display screen. Analyze the information received from the connected sensor devices. Produce an electronic installation report. Configuration of various NMEA protocols. ® M3 N 1o19' E 0o12' |1> N/A|2>0.00|3>0.10nm *********** Sensor Settings ************ BaudRate Sensor1:< 4800> CRC: auto Ignored:$HC---$-----$-----$----- 1>Start Monitor> BaudRate Sensor2: 4800 CRC: auto Ignored:$HC---$-----$-----$----- 2>Start Monitor> BaudRate Sensor3: 38400 CRC: auto Ignored:$HC---$-----$-----$----- 3>Start Monitor> | Save | Default | Analyze | Back (mÍ) (Mem) (ms) (mb) (m?) (m£í) MOB (SRM & Dynamic Keys: Sensor Settings [M5] [Save] Save Data Input [Up] / [Down] Select Data Field for Configuration [M6] [Default] Restore the default settings [Enter] Select Data Field for Configuration [M7] [Analyce] Analye you NMEA Data streem [Left] / [Right] Configure Data [M8] [Back] Return to Menu Configuration User Manual 55 Y1-03-0203 Rev.L Use this menu to set up the data speed 4800/9600/38400 baud. NOTE: This Configuration should be done from advanced user like installation technicians only. Therefore you will find more details in the installation manual. During the configuration process, the NAUTICAST is not operational. GPS Settings (Service Password protected) GPS Module: The screen provides means to switch the GPS Module between the ‘<^Blox>’ or ‘’. You can force the AlS to search again for the GPS Module installed. Selecting the wrong type of GPS module may result in invalid position information and/or malfunction so that your AlS can not operate correct. Select and with [Left] & ...

Эта инструкция также подходит к моделям:
Лодочное оборудование - Nauticast 2607 (3.99 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории