Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации Alliance Laundry Systems, модель 105

Производитель: Alliance Laundry Systems
Размер: 2.02 mb
Название файла:
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


To configure your 208V or 240V tumbler for 208V operation, you must remove the 240V configuration jumper located in the contactor box and replace it with the 208V jumper supplied with the information packet. This must be done prior to supplying power to machine. Failure to install proper configuration jumper may result in damage to sensitive electronic controls and may void warranty. To configure your 380V or 415V tumbler for 415V operation, you must remove the 380V configuration jumper located in the contactor box and replace it with the 415V jumper supplied with the information packet. This must be done prior to supplying power to machine. Failure to install proper configuration jumper may result in damage to sensitive electronic controls and may void warranty. (GAS AND STEAM OPL MICRO CONTROL MODELS ONLY) The ring ferrite provided in the information packet must be installed over the power leads during connection of electrical service. The ferrite protects the sensitive electronic controls from destructive electrical disturbances which may be present on power lines to the machine. Failure to properly install the ring ferrite may result in damage to the electronic controls and will void control warranty. Installation Instructions: 1. Immediately after connection of power leads and before applying power to machine, locate each of the incoming service leads including ground. 2. Snap the ring ferrite closed over all of the service leads inside of the contactor box as shown. It is important that the ferrite ring be installed inside the contactor box as shown. Do not install the ferrite outside of the box or other area. Make sure that service leads are in the center of the ferrite before closing the ring so not to pinch or damage leads. T225SE1A CONTACTOR BOX FERRITE RING JUMPER Figure 11 M414545 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 33 ELECTRICAL REQUIREMENTS For 28" wide Tumblers NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline only. Electrical connections should be made only by a qualified electrical contractor in accordance with all applicable local and national requirements. NOTE: DO NOT use aluminum wire. Heat Source Electrical Specs Wires Required and Terminal Block Connections Gas 120/60/1 L1, Neutral, and ground Gas 208-240/60/1 L1, L2, Neutral, and ground Gas 240/50/1 L1, Neutral, and ground Gas 120/50/1 L1, Neutral, and ground Electric 208/60/1 L1, L2, and ground Electric 240/60/1 L1, L2, and ground Electric 240/50/1 L1, Neutral, and ground Electric 208/60/3 L1, L2, and ground Electric 240/50/3 L1, L2, L3, and ground Electric 240/60/3 L1, L2, L3, and ground Electric 380/50/3 L1, L2, L3, Neutral, and ground Electric 415/50/3 L1, L2, L3, Neutral, and ground Electric 480/60/3 L1, L2, L3, and ground Table 4 ELECTRIC DRYING TUMBLERS 208V 60 HZ 1 PH 240V 60 HZ 1 PH 208V 60 HZ 3 PH 240V 60 HZ 3 PH 480V 60 HZ 3 PH 240V 50 HZ 1 PH 240V 50 HZ 3 PH 380V 50 HZ 3 PH 415V 50 HZ 3 PH Amp Rating 104 AMP 92 AMP 62 AMP 55 AMP 27 AMP 91 AMP 55 AMP 34 AMP 31 AMP Circuit Breaker 125 AMP 100 AMP 70 AMP 60 AMP 30 AMP 100 AMP 60 AMP 40 AMP 35 AMP Poles 2 2 3 3 3 2 3 3 3 Minimum Wire Size Per Canadian Elec. Code C22.1 1 AWG 2 AWG 4 AWG 6 AWG 10 AWG 2 AWG 6 AWG 8 AWG 8 AWG Table 5 GAS DRYING TUMBLERS 120V 1 Phase 60 Hz. 208/240V 1 Phase 60 Hz. 240V 1 Phase 50 Hz. 120V 1 Phase 30 Hz. Minimum Wire Size Per Canadian Elec. Code C22.1 14 AWG 16 AWG 16 AWG 14 AWG Disconnect Switch 15 AMP USE CIRCUIT BREAKER ONLY Fusetron 15 AMP Circuit Breaker 15 AMP 15 AMP 15 AMP 15 AMP No. of Poles 1 2 2 2 Table 6 34 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT M414545 ELECTRICAL REQUIREMENTS For 31.5" wide Tumblers NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline only. Electrical connections should be made only by a qualified electrical contractor in accordance with all applicable local and national requirements. NOTE: DO NOT use aluminum wire. Heat Source Serial Plate Voltage Terminal Block Connections Required Rated Current Breaker Rating Breaker Poles Recommended Wire Size Steam CSL 120V/60Hz/1ph L1, Neutral and ground * 20 Amps 1 12 AWG Gas & CSH 120V/60Hz/1ph L1, Neutral and ground * 15 Amps 1 14 AWG Gas & Steam 208 or 240V/60Hz/1ph L1, L2 and ground * 15 Amps 2 14 AWG Gas & Steam 230-240V/50Hz/1ph L1, Neutral and ground * 15 Amps 1 14 AWG Gas & Steam 208 or 240V/60Hz/3ph L1, L2, L3, and ground * 15 Amps 3 14 AWG Gas & Steam 380 or 415V/50Hz/3ph L1, L2, L3, and ground * 15 Amps 3 14 AWG Gas & Steam 460-480V/60Hz/3ph L1, L2, L3, and ground * 15 Amps 3 14 AWG Electric 208V/60Hz/1ph L1, L2, and ground 104 Amps 125 Amps 2 0 AWG Electric 240V/60Hz/1ph L1, L2, and ground 92 Amps 100 Amps 2 2 AWG Electric 240V/50Hz/1ph L1, Neutral and ground 90 Amps 100 Amps 1 2 AWG Electric 208V/60Hz/3ph L1, L2, L3, and ground 62 Amps 70 Amps 3 4 AWG Electric 240V/60Hz/3ph L1, L2, L3, and ground...

Эта инструкция также подходит к моделям:
Сушильные машины - 000 BTU (2.02 mb)
Сушильные машины - 80 (2.02 mb)
Сушильные машины - 250 C.F.M. (2.02 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории