Инструкция по эксплуатации Haier, модель HDE5000AW

Производитель: Haier
Размер: 3.01 mb
Название файла:
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


Certain extenuating circumstances could affect the performance of the dryer: 7 English 1. Only rigid metal duct work should be used. 2. Venting vertically through a roof may expose the exhaust system to down drafts causing an increase in vent restriction. 3. Running the exhaust system through an uninsulated area may cause condensation and faster accumulation of lint. 4. Compression of crimping of the exhaust system will cause an increase in vent restriction. 5. I n Canada, that only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the manufacturer shall be used. In the United States, that only those foil-type flexible ducts, if any, specifically identified for use with the appliance by the manufacturer and that comply with the UL Outline for clothes Dryer Transition Duct, Subject 2158A (2006), shall be used. 6. I n Canada, that the exhaust duct shall be 102 mm in diameter. In the United States, the required exhaust duct diameter. The exhaust system should be inspected and cleaned a minimum of every 12 months with normal usage. The more the dryer is used the more often you should check the exhaust system and vent hood for proper operation. Side and Bottom Exhaust For your convenience, your dryer can be exhausted through the side or the bottom. If you need to change the exhaust on the dryer to the side or the bottom of the cabinet, you will need to order the exhaust kit from your Haier dealer or call 1- 800-313-8495 RECOMMENDED MAXIMUM Exhaust Hood Types Recommended Use only for short run installations /■ — -H" ¡10.LT-Il ■T DIA. r>\ ay (6 Jh cm) No. of 90° elbows Rigid Metal Rigid Metal 0 90 ft. 60 ft. 1 60 ft. 45 ft. 2 45 ft. 35 ft. 3 35 ft. 25 ft. The total length of flexible metal duct shall not exceed 94 inches. 8 English GAS SUPPLY REQUIREMENTS Replace copper connecting pipe that is not plastic coated. Stainless steel or plastic-coated brass MUST be used. 1. I nstallation MUST conform with local codes. In the absence of local codes, installation must conform with the National Fuel Gas Code, ANSI Z223.1 (latest edition) or in Canada, the current CAN/CGA B149.1l 2. The gas supply line should be 1/2 inch (1.27cm) pipe. 3. I f codes allow, flexible metal tubing may be used to connect your dryer to the gas supply line. The tubing MUST be constructed of stainless steel or plastic-coated brass. 4. The gas supply line MUST have an individual manual shutoff valve installed within 6 feet (183cm) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA 54. In Canada, an individual manual shut-off valve MUST be installed in accordance with the B149.1, Natural Gas and Propane Installation Code. 5. A 1/8 inch (0.32cm) N.P.T. plugged tapping, accessible for test gauge connection, MUST be installed immediately upstream of the gas supply connection to the dryer. 6. The dryer MUST be disconnected from the gas supply piping system during any pressure testing o...

Эта инструкция также подходит к моделям:
Сушильные машины - CHDE5000AW (3.01 mb)
Сушильные машины - CHDE5300AW (3.01 mb)
Сушильные машины - HDE5000AW (3.01 mb)
Сушильные машины - CHDE5000AW (3.01 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории