The Tool must not cycle (fire). If it cycles (fires), stop immediately and have it repaired by a qualified service technician. 7. Hold the tool away or off of the workpiece. The Lower Safety (32) of the tool should return to its original position. Squeeze the Trigger (48). The tool should not cycle (fire). If the tool fires, stop immediately and have it repaired by a qualified service technician. 8. Depress the Lower Safety (32) against the workpiece and squeeze the Trigger (48). The tool must cycle (fire) only once. Release the Trigger and squeeze it again. The tool must not cycle (fire). With the Trigger held, carefully lift the nailer and press it against the workpiece again. The tool must not cycle (fire). If it fails to perform in the manner explained in bold, have it repaired by a qualified service technician. LOWER SAFETY (32) TRIGGER (48)QUICK CONNECTOR (87) TRIGGER (48) LOWER SAFETY (32) REV 11/06 Skus 91053, 91054 For technical questions, please call 1-800-444-3353. Page 7 92147, & 92185 Loading Nails ALWAYS WEAR ANSI APPROVED IMPACT SAFETY GOGGLES WHEN RELOADING OR DOING ANY OTHER MAINTENANCE ON THIS TOOL. Other people in the work area must also wear ANSI approved impact safety goggles. Warning! Make sure the Nailer is not attached to the air hose whenever loading the tool. 1. Slide the Tab (64) back and the Latch (78) will hold it in place. 2. Holding the nailer with the nose pointing slightly down, load a stick of nails into the top slot. 3. While holding the Tab back, carefully press the Latch. BE CAREFUL. When you press the Latch (78), the Tab (64) will spring forward with force. Slowly and cautiously allow the tab to slide forward. TAB (64) NAILS (91) LATCH MAGAZINE (PULLED (78) (74) BACK) Skus 91053, 91054 For technical questions, please call 1-800-444-3353. Page 8 92147, & 92185 Operating the Nailer 1. Attach the Nailer to the air supply at the Quick Connector (87). Start your compressor, and check the pressure making sure it is set at the recommended 75-125 PSI and not to go over the maximum PSI. 2. Rotate the Exhaust Cover (3) so that the exhaust air blast will be directed away from the operator. 3. To fire, place the nose of the Nailer on the workpiece. The Nailer should not fire if the nose is not depressed. Once depressed, gently and briefly squeeze the Trigger (48) once. Do not fire repeatedly. Nails could bounce off of one another, damaging the workpiece or causing PERSONAL INJURY. 4. Do not press the Lower Safety (32) of the Nailer against the work surface with excessive force. Allow the tool to do the work. Always allow the tool to recoil off the workpiece. 5. Caution: While working, dirt and sawdust may build up on the Lower Safety (32) of the Nailer. This can prevent normal operation. Remove buildup using compressed air. 6. When finished using the Nailer, always disconnect the tool from its compressed air supply. Empty the Magazine (74) completely of nails. Attempt to fire the Nailer into a piece of scrap wood to ensure it is disconnected and is incapable of firing any nails. 7. Make sure to store the Nailer in its Carrying Case in a clean, dry, safe location out of reach of children. QUICK CONNECTOR (87) TRIGGER (48) EXHAUST COVER (3) LOWER SAFETY (32) WORK SURFACE REV 11/06 Skus 91053, 91054 For technical questions, please call 1-800-444-3353. Page 9 92147, & 92185 Anytime anymaintenance or repairs are done (including clearing jams), FIRST: 1. Disconnect the Nailer from the air hose. 2. Empty the Magazine (74) completely. 3. Attempt to fire the Nailer into a piece of scrap wood to ensure that it is disconnected and is incapable of firing any nails. Clearing Jams 1. Occasionally a Nail may become jammed in the firing mechanism of the Nailer, making the tool inoperative. 2. To remove a jammed nail, disconnect the Nailer from its compressed air supply. Slide the Tab (64) back and empty the Magazine (74) completely of Nails. Attempt to fire the Nailer into a piece of scrap wood to ensure it is disconnected and is incapable of firing any nails. 3. Use a pair of needle nose pliers (not included) to remove the jammed nail (usually from the Upper Safety (28) and/or Lower Safety (32) areas). While holding the Tab back, carefully press the Latch. BE CAREFUL. When you press the Latch (78), the Tab (64) will spring forward with force. Slowly and cautiously allow the tab to slide forward. 4. Reconnect the air supply hose to the tool. 5. Press the Lower Safety (32) of the Nailer against a piece of scrap wood. 6. Test fire the Nailer several times, checking for proper operation. 7. If the Nailer is properly firing, you can continue to use the Nailer. Disconnect the air supply to the Nailer, and reload the Nails. Then, reconnect the air supply and continue working. 8. When finished working, Disconnect the air supply. Remove the Nails. Then, store the Nailer and nails in a location out of children’s reach. Skus 91053, 91054 For technical questions, please call 1-800-444-3353. Page 10 92147, & ...
Эта инструкция также подходит к моделям:Строительные пистолеты - 92147 (870.26 kb)
Строительные пистолеты - 92185 (870.26 kb)
Строительные пистолеты - 91054 (870.26 kb)