Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Campbell Hausfeld, модель PS240F

Производитель: Campbell Hausfeld
Размер: 7.95 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Always ground the pump and spraying surface. Always use a 3-wire grounded extension cord and power receptacle. . Do not use paints or solvents containing halogenated hydrocarbons such as methyl bromine, carbon tetrachloride, and ethyl iodine. Keep hose away from sharp objects. Bursting hoses may cause injury. Examine hoses regularly and replace if damaged. . Check hoses for weak or worn condition before each use, making certain that all connections are secure. . Keep area clean and free of paint or solvent containers, rags, and other flammable materials. TO rEDUCE ThE rISk OF INjUry: . Do not spray acids, corrosive materials, toxic chemicals, fertilizers, or pesticides. Using these materials could result in death or serious injury. . Do not kink or over-bend the hose. . Do not expose the hose to temperatures or to pressures in excess of those specified by the manufacturer. . Do not use the hose as a strength member to pull or lift the equipment. . Always wear appropriate gloves, eye protection, and a respirator or mask when painting. . Always work in a clean environment. Do not aim the spray gun at any dust or debris. . Do not operate or spray near children. Keep children, pets, and visitors away from equipment and work area at all times. . Do not over reach or stand on an unstable support. Keep effective footing and balance at all times. . Stay alert and watch what you are doing. . Do not operate the equipment when fatigued or under the influence of drugs or alcohol. FAIlUrE TO FOllOw ThESE INSTrUCTIONS CAN rESUlT IN SErIOUS INjUry INClUDING DEATh. 5 Operating Instructions and Assembly Instructions Airless Paint Sprayers Preparation Airless painting systems, unlike most other power tools, require additional care to ensure proper working order. Following these instructions will significantly increase the likelihood of having a positive paint experience. It is important that the painting equipment is flush/tested EACH time a new job is started. Each pump is tested at the factory with a fluid that must be flushed from the system prior to painting. It is also required prior to each successive use to flush the storage lubricant from the system. Use the solvent which will be used to clean the equipment. Refer to the paint manufacturer’s recommendations for cleaning fluids. Pump Assembly Assembly Instructions Too ls requi red : u 3/4 in. or Adjustable Wrench u 5/8 in. or Adjustable Wrench Asse mbly 1. Open packaging and check contents. 2. Remove the equipment and all parts from the carton. 3. If sprayer is on stand, no further frame assembly is necessary. If sprayer is on a cart, install handle in position shown on cover and tighten knobs. 4. Attach high pressure hose to pump and spray gun using a 3/4 inch wrench (See Figure Below). Do not attach suction assembly at this time. FIgure - Attach hose Suction Assembly Motor Pressure Valve Housing Outlet Valve Hose Adapter Prime/Spray Valve Suction Bell Assembly Inlet Valve Outlet Prime Button By-pass Hose Airless Paint Sprayers Operating Instructions and Assembly Instructions Turn Prime/ Spray Control to PRIME (knob is horizontal) Turn Pressure to HIGH (completely clockwise) 4 Use Finger to Check Inlet Valve 1 Starting Instructions While Pulling Trigger, Direct Fluid Stream Along Inside of Bucket 9 Power Switch Location 6 Attach Suction Assembly 3 Tip in Cleaning Position 8 7 Turn Prime/ Spray Control to SPRAY (knob is vertical) 5 Preparation (Continued) DO NOT ATTACH THE SUCTION ASSEMBLY UNTIL INSTRUCTED TO DO SO IN STEP 3. 1. Remove inlet valve cap and with your smallest finger, push on inlet valve stem to ensure it moves freely. 2. Push outlet prime button three times to ensure outlet valve is moving freely. 3. Attach suction assembly and bypass tube securely and place both suction and bypass tubes in cleaning solvent. 4. Turn pressure to High (completely clockwise). 5. Turn prime/spray control to the Prime position. 6. Turn power switch to the ON position. In a few seconds, cleaning solvent will begin to move up through the tube. Allow the fluid to circulate for one minute to ensure all air has been exhausted from the pump. 7. Turn prime/spray control to Spray position. Watch for any fluid leaks (See Troubleshooting Chart if leaks occur). NOTE: If unit is building pressure properly, the pump should produce a knocking sound, which indicates it has reached its hydraulic relief pressure. 8. When flushing the system with cleansing fluid (either prior to use with paint or during cleaning process) the spray tip can remain in the clean position. 9. Point spray gun into an empty waste bucket and pull trigger. To reduce splashing, direct the fluid stream along the inside of the bucket wall and well above the fluid level. 2 Push Outlet Prime Button Preparation (Continued) 10. After completing the flush/testing process, purge the pump of fluid. 11. Repeat the preceding steps using paint instead of cleaning solvent. NOTE: Strai...

Эта инструкция также подходит к моделям:
Распылители краски - PS231B (7.95 mb)
Распылители краски - PS240C (7.95 mb)
Распылители краски - PS250B (7.95 mb)
Распылители краски - PS250E (7.95 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории