tmpfs 190636 0 190636 0% /dev/shm
/dev/mapper/DP_Grp-DP_Vol 2780848 5768 2775080 1% /FileShare
4. Run the opt/omni/sbin/install/omniforsg.ksh script on the primary node:
$/opt/omni/sbin/install/omniforsg.ksh –primary
RUNNING: /opt/omni/sbin/omnidbutil -change_cell_name –force
DONE!
RUNNING: /opt/omni/sbin/omnisv.sh –stop
RUNNING: mkdir -p / FileShare /etc_opt_omni_server
RUNNING: cp -Rp /etc/opt/omni/server/. / FileShare /etc_opt_omni_server
RUNNING: mv /etc/opt/omni/server /etc/opt/omni/server.save
RUNNING: ln -s / FileShare/etc_opt_omni_server /etc/opt/omni/server
RUNNING: cp -Rp /var/opt/omni/server/. / FileShare /var_opt_omni_server
RUNNING: mv /var/opt/omni/server /var/opt/omni/server.save
RUNNING: ln -s / FileShare /var_opt_omni_server /var/opt/omni/server
cat: /etc/opt/omni/server/cell/installation_servers: No such file
RUNNING: echo dpi00180.ipr.com > /etc/opt/omni/client/cell_server
RUNNING: /opt/omni/sbin/omnisv.sh –start
HP Data Protector services successfully started.
RUNNING: /opt/omni/sbin/omnidbutil -change_cell_name –force
DONE!
RUNNING: /opt/omni/sbin/omnisv.sh –stop
HP Data Protector services successfully stopped.
Installing and integrating on the secondary node
1. Install Data Protector locally on the secondary node, by repeating step 1 of the primary node
installation.
2. Perform the failover of the shared disk on the secondary node, and run the following script:
$ opt/omni/sbin/install/omniforsg.ksh -secondary /FileShare
RUNNING: /opt/omni/sbin/omnisv.sh –stop
HP Data Protector services successfully stopped.
RUNNING: echo >> /FileShare/etc_opt_omni_server/cell/cell_info
RUNNING: cat /etc/opt/omni/server/cell/cell_info >> /
FileShare/etc_opt_omni_server/cell/cell_info
RUNNING: mv /etc/opt/omni/server /etc/opt/omni/server.save
RUNNING: mv /var/opt/omni/server /var/opt/omni/server.save
RUNNING: ln -s / FileShare /etc_opt_omni_server /etc/opt/omni/server
RUNNING: ln -s / FileShare /var_opt_omni_server /var/opt/omni/server
RUNNING: echo dpi00180.ipr.com > /etc/opt/omni/client/cell_server
RUNNING: echo CELL SERVER IS: ‘cat /etc/opt/omni/client/cell_server’
CELL SERVER IS: dpi00180.ipr.com
3. Check that the Data Protector services can be stopped and started without error by using the
following commands:
$/opt/omni/sbin/omnisv start
HP Data Protector services successfully started.
$/opt/omni/sbin/omnisv stop
HP Data Protector services successfully stopped.
Also check that you can open the Cell Manager GUI:
$/opt/omni/sbin/omnisv start
5
...Эта инструкция также подходит к моделям:
Программное обеспечение - HP Data Protector V6.10 Software (504.6 kb)
Программное обеспечение - HP Data Protector V6.11 Software (504.6 kb)
Программное обеспечение - HP Data Protector v6.20 English SW E-Media (504.6 kb)
Программное обеспечение - HP Data Protector v6.20 French SW E-Media (504.6 kb)