Войти:
Оценок - 2, средний балл: 3.5 ( )

Инструкция по эксплуатации Craftsman, модель 351.223140

Производитель: Craftsman
Размер: 1.65 mb
Название файла: ecdc7531-5da7-4bcb-8b09-764e9a2ea892.pdf
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


Figure 7 -Attaching Inlet ATTACH HOSE Refer to Figure 8. Hose needs to be attached to the inlet using hose clamp. To attach hose: • Slide hose clamp onto one end of hose. Loosen clamp screw if required to slide hose clamp onto hose. • Position the hose clamp wires on the hose grooves. • Slide hose with clamp onto inlet. • Tighten hose clamp screw to secure hose with inlet. • Slide other hose clamp onto the opposite hose end. This end will be connected to the dust producing machine Figure 8 -Attaching Hose DANGER: Do not permit fingers to touch terminals of plug when installing or removing the plug to or from the outlet. WARNING: Do not connect to power source until unit is completely assembled. POWER SOURCE • Motor is designed for operation on the voltage and frequency specified on motor nameplate. • Normal loads will be handled safely on voltages not more than 10% above or below the specified voltage. • Running unit on voltages not within range may cause overheating and motor burnout. GROUNDING INSTRUCTIONS Refer to Figure 9. • This tool is equipped with a 3-conductor cord. • Do not remove or alter grounding prong in any manner. In the event of malfunction or breakdown, grounding provides path of least resistance for electrical current to reduce risk of electrical shock. • Plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances. • The conductor with insulation having an outer surface which is green is equipment grounding conductor. If repair or replacement is necessary, make sure equipment grounding conductor is not connected to line terminal. • If power cord is worn, cut or damaged in any way, have it replaced immediately. Properly Grounded Outlet Grounding Prong 3-Prong Plug @I__ Figure 9 -3-Prong Receptacle CAUTION: improper connection of the equipment-grounding conductor can result in a risk of electrical shock. EXTENSION CORDS • The use of any extension cord will cause some drop in the voltage and loss of power. • Wires of the extension cord must be sufficient in size to carry the current and maintain adequate voltage. • Use the table below to determine the minimum wire size (A.W.G.) extension cord. • Use only 3-wire extension cords having 3-prong grounding type plugs and 3-pole receptacles which accept the tool plug. • If extension cord is worn, cut or damaged in any way, have it replaced immediately. Extension Cord Length Wire Size A.W.G. Up to 50 ft ....................................... 16 Note: Using extension cords over 50 ft. long is not recommended. DESCRIPTION The Craftsman Dust Collector is designed to remove and collect wood dust and wood chips from woodworking machinery. Collector bag collects dust and chips, and makes disposal of dust and chips easy. Collector features 2_/2x 72" intake hose. SPECIFICATIONS Motor Horsepower (Max. Developed) ................. 1 _t_ Voltage ...................................... 115 V Amperes ....................................... 9.0 Hertz .......................................... 60 Phase ....................................... Single RPM ......................................... 3450 Certification ................................... CSA Air Flow Rate .............................. 150 CFM Air Velocity ................................ 4400 FPM Maximum Static Pressure ........... 3.75" of water column Sound Level ................................ 76 dB A Inlet .......................................... 2I/Z Collector Bag Capacity ................ 36 gal. (4.9 cu. ft.) Collector Bag Rating ......................... 1 micron Weight ...................................... 55 Ibs Overall Size ........................... 173/4x 19 x 72" DUST COLLECTOR DANGER:Do not use this dust collector in a flammable or explosive atmosphere. Do not use to collect metal shavings or dust Consult National Fire Protection Association (NFPA) standards before setting up a dust collection system, especially NFPA 664. • Connect collector hose to dust producing machine using hose clamp. NOTE: For installations with more than one machine, it is recommended that Craftsman 22313 Shop Dust Collection System be used for best performance. NOTE: A longer hose may be used (maximum length is 40' of 2Yz" diameter hose). A larger diameter hose may be used, but length will be decreased. • Turn dust collector on before starting dust producing machine. EMPTYING COLLECTOR BAG Refer to Figure 10. DANGER:Turn switch off and remove plug from power source outlet before emptying collector bag. • Empty collector bag by lifting bag clamp handle and releasing spring connector from latch. Slide bag away from collar. Dispose of dust properly. • Mount collector bag by sliding bag over opening on collar. Position the spring connector into one of the slots on the latch and lock the clamp handle. Make sure collector bag is secure and rests flat on floor, so that floor supports the weight of wood dust and chips. WARNING: Turn switch off...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории