Инструкция по эксплуатации Universal Security Instruments, модель MCND401LCN

Производитель: Universal Security Instruments
Размер: 386.89 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


To check CO memory: 1. Pressand release the PEAK button on the alarm cover. The peak CO level is displayed on the screen. To reset and clear CO memory: 1. Press and hold the RESET button for 5 seconds until the CO memory reading is cleared. The screen will temporarility display "000" when the peak CO level is reset and then return to "- - -" after several seconds. NOTE: The highest CO level will be saved into memory until you clear it, even after a power interruption,. DO NOT clear the CO memory reading if you plan to call someone to investigate a CO problem. Clear the CO memory reading only after the investigator has checked your home. Natural gas levels will not display on the screen. REGULAR MAINTENANCE CLEANING YOUR ALARM: DO NOT use spray cleaning chemicals or insect sprays directly on or near the alarm. DO NOT paint over the alarm. Doing so may permanently damage the alarm. The outside can be wiped with a damp cloth. Do not use any household cleaning agents, ammonia- based cleaners, paints, varnishes or any other chemical on or near your alarm. AFTER CLEANING, REINSTALL YOUR ALARM. TEST YOUR ALARM BY USING THE TEST BUTTON. BATTERY REPLACEMENT: The CO/Gas alarm is powered (backup) by a 9 volt battery. The alarm has a low battery monitor circuit which will cause the alarm to sound a short "chirp" approximately every 40 seconds, for a minimum of 7 days, when the battery gets low. Replace the battery when this condition occurs. While observing polarity, push the replacement battery into the battery compartment until it is held securely in place. Carefully close the battery compartment cover. USE ONE OF THE FOLLOWING 9 VOLT BATTERIES FOR REPLACEMENT: Carbon type: Gold Peak GP1604S Alkaline type: Energizer 522; Duracell MN1604 Lithium type: Ultralife U9VL-J, U9VL-J-P These batteries are available at many local retail stores. Page 8 Use only the batteries specified. Use of different batteries may have a detrimental effect on the CO/Gas alarm. The constant exposures to high or low temperatures or high humidity may reduce battery life. IMPORTANT! The battery backup is designed to provide short-term emergency power to the alarm. Actual backup time depends on the strength (freshness) of the battery. The battery backup will not work unless a good battery is properly installed. Lithium Battery Models only - The Lithium battery is warranted to last for 10 years under normal operating conditions. Replace the battery with only Lithium type: Ultralife: U9VL-J and U9VLJ-9. NOTE: WEEKLY TESTING IS RECOMMENDED. CO AND NATURAL GAS ALARM LIMITATIONS Alarms have limitations. Like any other electronic device, CO and Gas Alarms are not foolproof. CO and Gas Alarms have a limited operational life. Your CO and Gas Alarm must be tested weekly, because it could fail to operate at any time. If your CO and Gas Alarm fails to test properly, or if its self-diagnostic test reveals a malfunction, immediately have the unit replaced (see last page for warranty information). CO and Gas Alarms can only sense CO which reaches the alarm's sensor. Carbon monoxide may be present in other areas without reaching the alarm. CO or gas could be present on one level of the home and not reach the alarm installed on a different level. For example, CO or gas in the basement may not reach an alarm on the second level, near the bedrooms. For this reason, we recommend you provide complete coverage by placing a CO and Gas Alarm on every level of the home. This alarm is not a smoke alarm. It will not sense smoke or fire. For early warning of fire, you must install smoke alarms, even though carbon monoxide can be generated by a fire. CO and Gas Alarms are not a substitute for property, disability, life or other insurance of any kind. Appropriate coverage is your responsibility. POTENTIAL SOURCES OF CO IN THE HOME Fuel-burning appliances, such as; heaters, gas or wood burning fireplaces, gas kitchen ranges or cooktops, gas clothes dryers. Damaged or insufficient venting; such as; corroded or disconnected water heaters, vent pipes, leaking chimneys, pipes or flues or cracked heat exchangers, blocked or clogged chimney openings. Improper use of appliances/devices; operating a barbeque grill or vehicle in an enclosed area (such as a garage or screened porch). Transient CO Problems: "transient" or on-again/off-again CO problems can be caused by outdoor conditions and other special circumstances. The following conditions can result in transient CO situations: 1. Excessive spillage or reverse venting of fuel-burning appliances caused by outdoor ambient conditions, such as: • Wind direction and/or velocity, including high gusts of wind. Heavy air in the vent pipes (cold/ humid air with extended periods between cycles). • Negative pressure differential resulting from the use of exhaust fans. • Simultaneous operation of several fuel-burning appliances competing for limited internal air. • Vent pipe connections vibrating loose from clothes...

Эта инструкция также подходит к моделям:
Пожарные сигнализации - MCN400LCN (386.89 kb)
Пожарные сигнализации - MCN400CN (386.89 kb)
Пожарные сигнализации - MCN600CN (386.89 kb)
Пожарные сигнализации - MCN600LCN (386.89 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории