Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Avalon s, модель 745

Производитель: Avalon s
Размер: 1.85 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


fireplace is allowed. NOTE: It is recommended yourchimney have a minimum 28 and a maximum of 144 square inch cross- sectional area to use a face seal connection, otherwise your chimney maynot havesufficient draw for the fireplace insert tooperate correctly. Airtight Insulated Clean-Out Remove damper or wire it open . AA. . AA. AA. See the section "Insert Placement Requirements" for minimum clearances AA. and hearth required. AA. AA. AA. Travis Industries 93508133 4020509 Operating Your Appliance 23 Operating Your Appliance 23 Safety Notice: If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Read and follow all of the warnings on pages 4 and 5 of this manual. Before Your First Fire Verify the Installation Before starting the stove, verify that the stove is properly installed and all of the requirements in this manual have been followed. Keep all flammable materials 36" away from the front of the stove (drapes, furniture, clothing, etc.). Curing the Paint 2 to 4 hours This heater uses a heat-activated paint that will emit some fumes while starting the first fire. Open doors and windows to the room to vent these fumes. This typically lasts two to four hours. You may also notice oil burning off of the interior of the heater. This rust-stopping agent will soon dissipate. Door Gasket - The door gasket might adhere to the paint on the front of the heater. Leave the door slightly ajar for the first fire and be careful when opening the door after the first fire. AAAAAAAAAAAA Over-Firing the Stove This stove was designed to operate at a high temperature. But due to differences in vent configuration, fuel, and draft, this appliance can be operated at an excessive temperature. If the stove top or other area starts to glow red, you are over-firing the stove. Shut the air control down to low and allow the stove to cool before proceeding. Opening the Door Turn the handle clockwise to un-latch. Swing the door open. The door becomes hot during use. Use a glove to open the door if the handle is hot. To prevent smoke from entering the room, open the door a small amount and let air enter the firebox. This stabilizes the air flow before opening the door completely. Travis Industries 93508133 4020509 24 Operating Your Appliance 24 Operating Your Appliance Starting a Fire Since the dawn of time man has debated the best way to start a fire. Some use the boy-scout "teepee", some prefer the "tic-tac-toe" stack. Either way, review the hints and warnings below to ensure proper fire starting. • Make sure the air control is pushed in. If additional air is needed, open the doors 1/4" during the first five minutes of start-up. Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or "freshen up" a fire in this stove. Keep all such liquids well away from the stove while it is in use. If using a firestarter, use only products specifically designed for stoves - follow the manufacturer's instructions carefully. If the smoke does not pass up the chimney, ball up one sheet of newspaper, place it in the center of the grate and light it. This should start the chimney drafting (this eliminates "cold air blockage"). Use plenty of kindling to ensure the stove reaches a proper temperature. Once the kindling is burning rapidly, place a few larger pieces of wood onto the fire. Travis Industries 93508133 4020509 Operating Your Appliance 25 Operating Your Appliance 25 Adjusting the Burn Rate Use the air control slider to control the burn rate of the stove. See the illustration below for details. Low Burn (air control closed) High Burn (air control open) Use the air control to change the burn rate. Approximate Air Control Settings: Overnight Burn .............. Fully down to 1/64" open (up) Medium Burn.................. 1/64" to 1/32" open Medium High Burn ........ 1/32" to 1/16" open High Burn........................ 1/16" to fully open (up) The air control becomes hot during operation - use gloves or a tool to prevent burns. The air control may take several minutes to influence the burn rate. When making adjustments, you may wish to let the stove burn for 10 minutes to gauge performance. Ash Removal ASHES Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a noncombustible floor or on the ground, away from all combustible materials, pending final disposal. If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled. Travis Industries 93508133 4020509 26 Operating Your Appliance 26 Operating Your Appliance Optional Blower Operation The blower will turn on once the stove is up to temperature. This is typically 15 to 30 minutes after starting th...

Эта инструкция также подходит к моделям:
Плиты - 790 (1.85 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории