Войти:
Оценок - 3, средний балл: 4.3 ( )

Инструкция по эксплуатации England's Works, модель 49-SHC22

Производитель: England's Works
Размер: 1.28 mb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Do not install a flue damper of any kind in this system, and do not connect this unit to a flue system serving another heating appliance. Through the Wall To vent the unit through the wall, connect the pipe adapter to the exhaust motor adapter. If the exhaust adapter is at least eighteen inches (18”) above ground level, a straight section of corn pipe can be used to initially pass through the wall (see Illustration 1). Your dealer or our factory should be able to provide you with a kit that will handle most of this installation, which will include a wall thimble that will allow the proper clearances through a combustible wall. Once outside the structure, a three-inch (3”) clearance should be maintained to the outside wall and a clean out tee should be placed on the pipe that extends through the wall. We recommend a minimum of three feet (3’) of vertical pipe with a 90-degree turn away from the house. At this point, a one-foot (1’) section and horizontal cap will complete the installation (see Illustration 1). A wall strap should be placed just below the last 90-degree section to make the system more stable. If you live in an area that has heavy snowfall, it is recommended the installation be taller than three feet (3’) to get above the snowdrift line. The same type installation can be used if your stove is below ground level by adding the clean- out section and vertical pipe inside until ground level is reached. However, we recommend basement installation be performed only by a professional installer. For basement installations, a 3” (three inch) pipe and coupler must be used for Outside Combustion Air, and a minimum clearance of 3’ (three feet) must be maintained outside the dwelling from the ground to the Corn Vent Exhaust Pipe. The through-the-wall installation is the least expensive and simplest installation. In a through- the-wall installation you should be mindful of the snowdrift line, as well as dead grass and leaves. We recommend a three foot (3’) minimum vertical rise on the inside or the outside of the dwelling. Never terminate the end vent under a deck, in an alcove, under a window or between two windows. Text Box: Call (800) 516-3636 to inquire about the AC-33000 Through-the-Wall Kit or Visit our web site at HTUfor ordering information! Through the Ceiling When venting the stove through the ceiling, the pipe is connected the same as through the wall, except the clean out tee is always on the inside of the house, and a 3” adapter is added before the clean-out tee. You must use the proper ceiling support flanges and roof flashing supplied by the pipe manufacturer -- follow the pipe manufacturer’s directions and Illustration 1 in this manual. It is important to note that if your vertical runs of pipe are more than fifteen feet (15’) at this point, the corn vent pipe should be increased to four inches (4”) in diameter. Do not exceed four feet (4’) of pipe on a horizontal run, and do attempt to use the least number of elbows in the flue system. If an offset is used it is better to install a 45-degree elbow whenever possible. Please remember, installing elbows may inhibit your draft by up to 30% per elbow. Outside Air (Outside Combustion Air Intake) Outside air is mandatory for this unit to operate properly. This unit has been designed and tested with this connection, because so many homes are airtight and there is not adequate combustion air available inside the dwelling. The air intake pipe is located on the bottom side of the burn pot (from the rear) and measures 1 .” inside diameter (I.D.). The connection can be made with a metal 1 7/8 ” I.D. coupler and pipe (see “Important Information” section of manual), and should exit through the wall. Be sure to secure the pipe to the unit with a clamp or aluminum tape. The outside end of the pipe should be covered (screened) to prevent foreign matter from entering the system. Our Outside Air Kit (Part Number PU-OAK) can be used. If the unit is located below ground level, you will need to run the pipe up and then outside the dwelling. NOTE: If the total run of the connection exceeds 6’, if more than 2 elbows are used, or if a basement installation, use 3” metal pipe (and coupler) instead. Mobile Home Installation Secure the heater to the floor using the two holes in the pedestal. If the unit is on a combustible surface, you will need to drill matching holes in the floor protection that you choose (see Floor Protection section). Do not disturb the structural integrity of the home, and be sure the unit is permanently electrically grounded to the chassis of your home. Remember that outside combustion air is mandatory, and not to install the unit in a sleeping room of the home. Important Notes Concerning Installation: Text Box: IMPORTANT: Improper hook-up (too much pipe, too many elbows, etc.) will cause the unit not to operate. Call Customer Service (800-245-6489) if you have questions about your hook-up or if your unit will not oper...

Эта инструкция также подходит к моделям:
Плиты - 10-CDV (1.28 mb)
Плиты - 49-TRC22 (1.28 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории