WHAT DO YOU DO IF YOU SMELL GAS . Do not try to light any appliance. . Do not touch any electrical switch . Do not use any phone in your building. . Immediately call your gas supplier from a neighbors phone. Follow the gas suppliers instructions . If you can not reach your gas supplier call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Comprising Servicing, Installation & Users Instructions & Cooking Guide Remember, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by AGA. PLEASE READ THESE INSTRUCTIONS BEFORE USING THIS APPLIANCE INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE CUSTOMER: KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE 04/06 EINS 512635 NATIONALLY RECOGNISED For use in USA/Canada TESTING LABORATORY CONTENTS SECTION PAGE INSTALLATION SECTION 3 TECHNICAL DATA 4 INSTALLATION 5 FITTING AND PRODUCT DIMENSIONS 6 ELECTRICAL CONNECTION 7 - 8 CONNECTING TO GAS 9 LOCATION 10 COOKER STABILITY 11 - 12 PRESSURE TESTING 12 LEVELLING AND MOBILITY WHEELS 13 FITTING OF HOTPLATE CASTINGS AND PAN 14 - 17 SUPPORTS SPLASHBACK 18 USERS GUIDE 19 GENERAL INFORMATION 20 SAFETY PRECAUTIONS AND HINTS 21 PRODUCT VIEW 22 CONTROL PANEL 23 GAS HOTPLATE 24 - 25 TO FIT PAN SUPPORTS 26 SETTING UP THE COOKER FOR USE 27 SIMMERING OVEN 28 SIMMERING OVEN RECIPES 29 - 32 THE BROILER 33 THE OVENS 34 OVEN COOKING GUIDE 35 - 39 THE MINUTE TIMER 40 AUTOMATIC COOKING CONTROL 41 - 42 CLEANING AND CARING FOR YOUR COOKER 43 - 48 SERVICING SECTION 49 SERVICING 50 - 58 WIRING DIAGRAM 59 2 Installation Section Remember, when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by AGA. CAUTION: THIS UNIT IS HEAVY, PROPER EQUIPMENT AND ADEQUATE MANPOWER MUST BE USED IN MOVING THE RANGE TO AVOID DAMAGE TO THE UNIT OR THE FLOOR 3 TECHNICAL DATA HOTPLATE NATURAL GAS L.H.F. R.H.F. R.H.R. L.H.R. CENTRE CENTRE WOK FRONT REAR BURNER TYPE ULTRA-RAPID RAPID RAPID SEMI-RAPID SEMI-RAPID ULTRA-RAPID MAXIMUM HEAT 6 kW 3.22 kW 3.22 kW 1.91 kW 1.91 kW 5 kW INPUT BTU’s/hr 20,500 11,000 11,000 6,500 6,500 17,000 INJECTOR MARKING MAIN 215 155 155 118 118 190 SECONDARY V ---- PRESSURE POINT POSITION: REAR RH SIDE OF HOTPLATE PRESSURE SETTING: 4” W.G. BURNER IGNITION: H.T. SPARK PROPANE L.H.F. R.H.F. R.H.R. L.H.R. CENTRE CENTRE WOK FRONT REAR BURNER TYPE ULTRA-RAPID RAPID RAPID SEMI-RAPID SEMI-RAPID ULTRA-RAPID MAXIMUM HEAT 5 kW 3.1 kW 3.1 kW 1.8 kW 1.8 kW 4 kW INPUT BTU’s/hr 17,000 10,600 10,600 6150 6150 14,000 INJECTOR MARKING MAIN 112 94 94 72 72 108 SECONDARY X ----- PRESSURE POINT POSITION: REAR RH SIDE OF HOTPLATE PRESSURE SETTING: 10” W.G. BURNER IGNITION: H.T. SPARK ELECTRIC GRILL AND OVENS WEIGHT OF APPLIANCE: 220 kg TOP OVEN POWER RATING - 2.2 kW BROILER ELEMENT -POWER RATING 2.45 kW SLOW COOKING OVEN -POWER RATING 1.0 kW LOWER OVEN (FAN) - 2.2 kW 240 VOLT 60 Hz SINGLE PHASE 30 AMP The data plaque is located on a pull out plate - lower front of appliance (See Fig. 10, Page 19). TYPICAL SECTION VIEW OF FLAMES: 15/16” 9/16” 7/8” 1/2”3/4” 9/16” LHF HOTPLATE BURNER CR HOTPLATE BURNER RHF & RHR HOTPLATE BURNER LHR & CF HOTPLATE BURNER 4 INSTALLATION CAUTION: THIS INSTALLATION MUST CONFORM WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL FUEL GAS CODE, ANSI Z223.I/NFPA 54 AND NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (IN CANADA CAN/CGA-B149) AND ONLY USED IN A WELL VENTILATED SPACE, READ THESE INSTRUCTIONS BEFORE INSTALLING OR USING THIS APPLIANCE. PRIOR TO INSTALLATION, ENSURE THAT THE LOCAL DISTRIBUTION CONDITIONS (NATURE OF GAS AND GAS PRESSURE) AND THE ADJUSTMENTS OF THE APPLIANCE ARE COMPATIBLE. THE GAS ADJUSTMENT CONDITIONS FOR THIS APPLIANCE ARE STATED ON THE DATA PLATE WHICH IS SITUATED IN THE CENTRE VENT SLOT NEAR THE BASE OF THE FRONT PLATE. This appliance is not connected to a combustion products evacuation device. it shall be installed and connected in accordance with current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation. It should be in accordance with any relevant requirements of the Gas Region and Local Authority. The appliance must be disconnected from the gas supply piping system during any pressure testing of that system test pressure in excess of 1/2 psi (3.5 kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply system at test pressures equal to or less than 1/2 psi (3.5 kPa). On completion, test the gas installation for soundness and purge. Leak testing of the appliance shall be conducted according to the manufactur...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории