Скачали: 0   Размер: 534 kb   Производитель: Southbend  
Категория: Пароварки
@name

Counter Steam The 24/7 warranty is effective on all Southbend equipment. For equipment down we will send a service technician any time - weekday or weekend. 24/7 Warranty 1100 Old Honeycutt Road Fuquay-Varina, North Carolina 27526 919-762-1000 • Fax 919-552-9798 Counter Steam (02/08) Rev 1 Gold Steam StratoSteam Counter SteamerPATENTED• Convection Steam Distribution System Requires no fan or blower • Boilerless design, NO routine deliming • Preheat time - LESS THAN 5 MINUTES, decreasing • cook t

Скачали: 1   Размер: 987 kb   Производитель: Southbend  
Категория: Пароварки
@name

1178410 1178410 DRAIN PAN WELD ASM. 1333045 DRAIN VENT TUBE ( AIR VEN 1178353 DUAL HEATING ELEMENT 1178359 DUAL HEATING ELEMENT 1178526 ELBOW, 90 DEG. 1"NPT FEM, 1178656 1178670 ELBOW, 90 DEG, STR. 1/2" 1178354 ELEMENT BLOCK, 220V,CENTE 1178360 ELEMENT BLOCK, 220V,OUTER 1178355 ELEMENT BLOCK, 240V,CENTE 1178361 ELEMENT BLOCK, 240V,OUTER 1178358 ELEMENT BLOCK, 480V,CENTE 1178364 ELEMENT BLOCK, 480V,OUTER 1178332 1178332 FITTING,3/4 HOSE ID X 1/2 1178423 FITTING,3/4" KYNAR HOSE,E 1178422 1178422 F

Скачали: 0   Размер: 1 mb   Производитель: Southbend  
Категория: Пароварки
@name

5 lbs. 20 (4 oz.) 20 (4 oz.) 12 12 Full/Perforated Full/Perforated Cabbage Green, Cut Into Wedges Red, Cut Into Wedges 24 16 15 18-20 Full/Perforated Full/Perforated Cauliflower Fresh, Whole Fresh, Whole Frozen, Flowerettes 2 lbs. 2 lbs. 12 oz. 5 lbs. 8 (4 oz.) 11 (4 oz.) 20 (4 oz.) 9-10 15 10-12 Full/Perforated Full/Perforated Full/Perforated Corn Fresh, Cob, 4-5 Inch Ears Frozen - Whole Kernel Frozen - Cob, 6 Inch Ears 5. lbs. 5 lbs. 9 lbs. 15 20 (4 oz.) 14 13-15 8 12-14 Full/Perforated Full/P

Скачали: 1   Размер: 987 kb   Производитель: Southbend  
Категория: Пароварки
@name

Check that circuit breaker is ON and that proper voltage is available at main fuse block. Check voltage across terminals 1 and 6 of terminal block (see Fig. 4 on page 21). Does voltage meet specifications? No Yes DISCONNECT POWER AT CIRCUIT BREAKER. Remove control panel without disconnecting plug. Turn lever to "ON" position. Reconnect power. Check voltage between A and B on control panel fuse bl k (see Figure 4 on page 21). Replace elements and main fuses (see Fig. 6 on page 23). Is measured re

Скачали: 0   Размер: 3 mb   Производитель: Southbend  
Категория: Пароварки
@name

Read the installation, operation and maintenance instructions UlüFOLHjhly before installing ano operating this equipment. "Our Goa/—First Time Fix" «00 Otd Heneyeuts Hsad * Fuquay-Vanina. NC 27526 fJ1&JS5£-&tei * (000) 34£-2£5fi FAX (EQOJ &1D*e&t5 , FAX f&îfl) SS3-3È82 m COUNTERTOP CONVECTION STEAMER Manual 1177S9Ï (03 i0) $ Ii .00 IMPORTANT FOR FUTURE REFERENCE Fp&ase complete irTtmtnaiioti snS 'starn this manual lor the № of the equipment MODEL «__________ SERIAL #_ DATE PU HC HAS ED

Скачали: 1   Размер: 974 kb   Производитель: Southbend  
Категория: Пароварки
@name

Failure to do so could result in serious injury or damage. Drains must be kept clean and clear of debris. ! WARNING: SHOCK HAZARD DO NOT GET WATER IN THE CONTROLS. This could result in expensive repairs and/or electrical shock. De-energize all power to equipment before cleaning the equipment. DAILY CLEANING 1. Turn lever to the “OFF” position. 2. Remove pan guides. 3. Clean all interior surfaces with soap, water, and a non-metallic pad. Occasional use of a deliming solution such as Lime-A-Way is

Скачали: 3   Размер: 974 kb   Производитель: Southbend  
Категория: Пароварки
@name

DISCONNECT POWER AT CIRCUIT BREAKER. 2. Remove rear cover from unit. 3. Disconnect float switch lead wires from wires B40 and B42. 4. Disconnect wires B73 and B74 from the pressure switch. 5. Remove lid from float box. 6. Make sure float travels freely along stem of float switch. 7. Place test leads in float switch terminals as shown. 8. Hold lid in same orientation as when installed. 9. Check continuity. There should be continuity. Replace as necessary. 10. Flip lid over. 11. Check for continui

Скачали: 7   Размер: 1 mb   Производитель: Southbend  
Категория: Пароварки
@name

Figure 6 90° Air Gap Air Gap Air Gap Stand Pipe Floor Drains INSTALLATION OPERATOR’S MANUAL 1183437 PAGE 11 OPERATION SEZ SERIES COUNTERTOP STEAMERS OPERATION OPERATION STARTUP 1. Turn lever to “ON” position. 2. Unit will fill automatically and be ready for operation in 11 minutes. NOTICE: WATER SPECIFICATION To meet warranty requirements, supply water must meet the following specification: Total Dissolved Solids (TDS) ...........60 PPM Hardness..........................................2 Grains

Скачали: 1   Размер: 1 mb   Производитель: Southbend  
Категория: Пароварки
@name

Check voltage across terminals 1 and 2 of terminal block (see Figure 7 on page 24). Yes No Replace control panel fuses. No Yes Does voltage match serial plate voltage? No Yes Does voltage match serial plate voltage? Does voltage match serial plate voltage? DISCONNECT POWER AT CIRCUIT BREAKER. Check resistance between contactor terminals (see Figure 8 on page 25). Test power switch or adjust so Replace “ON” light; that it is actuated properly by continue on next page. cam on valve shaft. Replace

Скачали: 9   Размер: 1 mb   Производитель: Southbend  
Категория: Пароварки
@name

15, 2001, check and AT CIRCUIT BREAKER. Is “CHECK WATER LEVEL” light on with door closed? Check all main fuses or circuit breaker, replace as necessary. Unit not heating up properly, or not cooking as fast, “ON” light lit. No Yes Drain unit. Turn unit on with door open. Add two gallons of water THROUGH TROUGH. Close door. Wait 10 minutes. Open door. Depress and hold door switch. Does unit have water? Add water according to start- up instructions on door. Wait 5 minutes, light should go off. Is b