Войти:
Оценок - 1, средний балл: 5 ( )

Инструкция по эксплуатации Pentax, модель R-335(N)

Производитель: Pentax
Размер: 875.66 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


2. Selection of Prism Constant : [PRISM CONST] Select whether the Prism Constant to be input is set to 0 mm, - 30mm or to an arbitrary value to be entered from the keyboard. 3. Selection of Reflector sheet Constant : [SHEET CONST] Select whether the target constant to be input is set to 0 mm, or to an arbitrary value to be entered from the keyboard. 4. Selection for Refraction & Curvature Corrections : [CRV/REF CORR] Select whether the correction factor to be input for both differences (Refraction, Curvature) is set to 0.14, 0.2, or none (NIL). Selecting “3. NIL” results in no correction of both values. 5. Selection of Tilt Compensation : [COMP AXIS] Select whether Tilt Compensation is to be single-axis compensation, dual-axis compensation, or disabled (NIL). . The factory default for each instrumet condition is marked by . 56 1. AUTO 2. ATM INPUT 3. ppm INPUT 4. NIL 1. 2 AXES 2. AXIS 3. NIL 1. -30mm 2. 0mm 3. INPUT 1. 0mm 2. INPUT 1. 0.14 2. 0.2 3. NIL 1. 3 AXIS 2. 2 AXIS 3. 1 AXIS 4. NIL PENTAX R-300 (p53-64) 10/30/02 11:13 AM Page 57 8-8 Initial Setting 2 1. Selection of Minimum Distance measurement unit : [MEAS. MIN DISP] COARSE or FINE: 2. Selection of the Shot count : [SHOT COUNT] Select whether the shot count for Shot distance measurement is to be 1,3, 5, or an arbitrary count to be entered. 3. Setting the Shot input : [SHOT INPUT] Set the shot number for Shot distance measurement. 1. COARSE 2. FINE 1. 1 TIME 2. 3 TIMES 3. 5 TIMES 4. INPUT 0 3 TIMES The valid range of values for the shot number is from 1 to 99. . This setting is enabled only when the shot number (Above 2.) has been set to “4. INPUT”. 4. Selection of Laser plummet : [LD PLUM.] Laser plumb ON/OFF is selected. 5. Selection of Tilting angle display : [TILT DISP.] X and Y tilting values are displayed. 6. Selection for Minimum tilt display : [TILT DISP. UNIT] COARSE or FINE: 7. Selection of Reflectorless range : [RANGE] If you need the Normal or Long range. 8. Selection of Long range message : [MESSAGE] If you need the long range message. 9. Selection of Long range setup : [SET UP] If the above No.7 selection is required each time or permanent. 8 INITIAL SETTING 1. COARSE 2. FINE 1. NORMAL 2. LONG 1. ON 2. OFF 1. EACH TIME 2. PERMANENT 1. OFF 2. ON 1. OFF 2. ON 57 PENTAX R-300 (p53-64) 10/30/02 11:13 AM Page 58 8 INITIAL SETTING 10.Selection of primary MEAS setting : [PRIM. MEAS KEY] Select whether the primary distance measurement is MEAS SHOT or MEAS CONT or TRACK SHOT or TRACK CONT. 11.Selection of second MEAS setting : [SEC. MEAS KEY] Select whether the second distance measurement is TRACK CONT or TRACK SHOT or MEAS CONT or MEAS SHOT. 12.Selection of Minimum angle display : [MIN UNIT ANG] Select whether to set the minimum angle display mode to “COARSE (5 seconds)” or “FINE (1 second)”. 1. MEAS SHOT 2. MEAS CONT 3. TRACK SHOT 4. TRACK CONT 1. TRACK CONT 2. TRACK SHOT 3. MEAS CONT 4. MEAS SHOT 1. COARSE 2. FINE 13.Selection of Vertical angle style : [V. ANG. STYLE] Select whether the 0 point for vertical angle is set to be “Z.0”, “H.0” or “COMPAS”. 14.Selection for Automatic power-off function : [AUTO OFF] Select the time interval (10, 20, or 30 minutes) for activating the automatic power-off function, or select NIL, disabling the function. 1. Z. 0 2. H. 0 3. COMPAS 1. 10 MIN 2. 20 MIN 3. 30 MIN 4. NIL . The automatic power-off function automatically turns the power supply off after the specified period of time (in minutes) when no operation for distance measurement or for key entry has been performed with the angle remaining unchanged. 15.Selection for Distance measurement automatic power- off function : [EDM OFF] Select the time interval (3, 5, or 10 minutes) for activating the distance measurement automatic power-off function, or select NIL, disabling the function. 1. 3 MIN 2. 5 MIN 3. 10 MIN 4. NIL . The distance measurement automatic power-off function automatically power- off distance measurement after the specified period of time when no key operation has been performed with the measured value remaining unchanged (over about 0.1 m) during measurement. 58 PENTAX R-300 (p53-64) 10/30/02 11:13 AM Page 59 16.Selection for Automatic illumination power-off function : [ILLU. OFF] Select the time interval (3, 5, or 10 minutes) for activating the automatic illumination power-off function, or select NIL, disabling the function. 17.Selection for Distance measurement buzzer : [DIST. BUZ] Select whether to enable or disable the beep when the prism receives a light during distance measurement or during repeated distance measurement. 18.Selection for H. angle 90° buzzer : [QUAD BUZ] Select whether to enable or disable the beep at every 90° during angle measurement. 19.Selection of Distance measurement signal : [MEAS. SIGNAL] Select whether to display a signal indicator or AIM value to be displayed from when distance measurement is started to when measured data is displayed. 20.Selection of Automatic distance measurement : [AUTO MEAS.] Automatic ...

Эта инструкция также подходит к моделям:
Оптические приборы - R-315(N) (875.66 kb)
Оптические приборы - R-315(N) (875.66 kb)
Оптические приборы - R-322(N) (875.66 kb)
Оптические приборы - R-323(N) (875.66 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории