For tubing length other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. These recommendations do not apply to Long Line Length Installations that exceed 75 feet or where there is more than 40 feet vertical separation between indoor and outdoor units. (Lengths in excess of 75 feet or more than 40 feet vertical separation are not recommended.) Note: See unit installation instructions for proper installation. COOLING PERFORMANCE DATA OUTDOOR UNIT MODEL AIR HANDLER RATINGS AT STANDARD CONDITIONS COOLING DATA AT EXTENDED OUTDOOR AMBIENTS F.M.B.T.U.H. BTUH SEER* CFM 80 85 90 95 100 105 110 115 CH18ABD1VF AFPB24A1 18,000 13 650 TOTAL 19,450 18,900 18,450 18,000 17,650 17,200 16,750 16,400 SENSIBLE 15,250 14,950 14,600 14,200 14,050 13,800 13,500 13,250 CH24ACD1VF AFPB24B1 24,000 13 840 TOTAL 25,800 25,150 24,600 24,000 23,450 22,900 22,350 21,950 SENSIBLE 19,900 19,500 19,050 18,700 18,450 18,000 17,650 17,300 CH30ACD1VF AFPB36A1 28,000 13 1,000 TOTAL 30,050 29,450 28,750 28,000 27,200 26,550 25,800 25,250 SENSIBLE 23,100 22,600 22,050 21,700 21,450 21,050 20,800 20,550 CH36ACD1VF AFPB36A1 34,000 13 1,200 TOTAL 36,350 35,500 34,800 34,000 33,250 32,550 31,700 30,950 SENSIBLE 28,300 27,850 27,650 27,250 26,950 26,750 26,350 26,050 CH42ACD1VF AFPC48A1 40,000 13 1,350 TOTAL 42,700 42,550 40,950 40,000 39,000 38,000 37,400 36,800 SENSIBLE 33,250 32,900 32,100 31,500 30,550 29,600 28,450 27,600 CH48ACD1VF AFPC48B1 46,000 13 1,550 TOTAL 49,300 48,150 46,950 46,000 44,850 43,650 42,500 41,400 SENSIBLE 40,950 39,750 38,100 36,000 34,800 33,550 32,350 31,150 CH60ACZ1VF AZFPC60B1 56,000 13 1,750 TOTAL 60,550 59,000 57,450 56,000 54,300 52,450 51,100 49,850 SENSIBLE 44,550 43,950 43,100 42,350 41,700 40,950 40,500 39,600 *TDR required to obtain SEER rating. 4 Specifications subject to change without notice. Split System Heat Pump 5 Specifications subject to change without notice. AIR IN AIR IN (FRONT) AIR DISCHARGE AIR IN C B F AIR DISCHARGE FIELD POWERSUPPLY CONNECTION1 1/ 8" HOLEFIELD CONTROLSUPPLY CONNECTION1/ 4" HOLE LIQUID LINECONNECTIONDVAPOR LINECONNECTIONE A DIMENSIONS System Heat Pump 5 Specifications subject to change without notice. AIR IN AIR IN (FRONT) AIR DISCHARGE AIR IN C B F AIR DISCHARGE FIELD POWERSUPPLY CONNECTION1 1/ 8" HOLEFIELD CONTROLSUPPLY CONNECTION1/ 4" HOLE LIQUID LINECONNECTIONDVAPOR LINECONNECTIONE A DIMENSIONS Fedders Corporation 505 Martinsville Rd. Liberty Corner, NJ 07938 USA (908) 604-8686 Form No. F-CH13 All product specifications reflect available information at the printing of this brochure. Fedders reserves the right to revise or modify products and/or specifications without notice. Copyright ©2007 Fedders North America, Inc. Fedders is a registered trademark of Fedders North America, Inc. Split System Heat Pump FD-017-0507-m 6 Specifications subject to change without notice. CH 24 A B D 1 V F * A Product Type C = Air Conditioner CH = Heat Pump Nominal ...
Эта инструкция также подходит к моделям:Насосное оборудование - CH18ABD1VF (131.37 kb)
Насосное оборудование - CH24ACD1VF (131.37 kb)
Насосное оборудование - CH30ACD1VF (131.37 kb)
Насосное оборудование - CH42ACD1VF (131.37 kb)