Войти:
Оценок - 1, средний балл: 4 ( )

Инструкция по эксплуатации Fedders, модель CH30ACD1VF

Производитель: Fedders
Размер: 131.37 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


OD) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 SUCTION LINE CONNECTION SIZE (In. OD) 3/4 3/4 7/8 7/8 7/8 7/8 7/8 RECOMMENDED LINE SET LIQUID TUBE DIAMETER (In. OD) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 RECOMMENDED LINE SET SUCTION DIAMETER (In. OD) 3/4 3/4 7/8 7/8 7/8 1 1/8 1 1/8 FACTORY CHARGE - OZ. 103 164 154 164 207 233 233* NOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit. ALL motors/compressors contain internal overload protection. 1. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 2. Time delay fuses may be used in place of HACR circuit breaker. * Unit uses R-410A refrigerant. 2 Specifications subject to change without notice. Product Specifications ARI CERTIFIED COMBINATION RATINGS UNIT SIZE OUTDOOR MODEL INDOOR MODEL FACTORY SUPPLIED ENHANCEMENT COOLING HEATING TOTAL CAPACITY SEER EER HIGH TEMP LOW TEMP HSPF CAPACITY COP CAPACITY COP 18 CH18ABD1VF AFPB24A1 TXV, TDR 18,000 13.0 11.0 17,300 3.42 11,100 2.36 8.2 CH18ABD1VF AFPB24B1 TXV, TDR 18,000 13.0 11.0 17,300 3.42 11,100 2.36 8.2 24 CH24ACD1VF AFPB24B1 TXV, TDR 24,000 13.0 11.4 24,000 3.42 15,000 2.20 8.2 30 CH30ACD1VF AFPB36A1 TXV, TDR 28,000 13.0 11.5 28,000 3.50 18,200 2.30 8.2 36 CH36ACD1VF AFPB36A1 TXV, TDR 34,000 13.0 11.5 34,000 3.50 22,000 2.50 8.2 42 CH42ACD1VF AFPC48A1 TXV, TDR 40,000 13.0 11.5 40,000 3.42 23,000 2.30 8.2 CH42ACD1VF AFPC48B1 TXV, TDR 40,000 13.0 11.5 40,000 3.42 23,000 2.30 8.2 48 CH48ACD1VF AFPC48B1 TXV, TDR 46,000 13.0 11.5 44,000 3.42 28,400 2.50 7.8 60 CH60ACZ1VF AZFPC60B1 TXV, TDR 56,000 13.0 11.2 56,000 3.42 38,000 2.30 8.2 SEER – Seasonal Energy Efficiency Ratio COP – Coefficient of Performance TDR – Time – Delay Relay HSPF – Heating Seasonal Performance Factor EER – Energy Efficiency Ratio NOTES: 1. Tested combination per ARI 210/240 standard. Fedders air handlers contain the TDR as standard equipment. 2. Supplemental electric heat is not included. 3. Ratings are based on: Cooling Standard: 80.F db 67.F wb indoor entering air temperature and 95.F db air entering outdoor unit. High – Temp Heating Standard: 70.F db indoor entering air temperature and 47.F db 43.F wb air entering outdoor unit. Low – Temp Heating Standard: 70.F db indoor entering air temperature and 17.F db 15.F wb air entering outdoor unit. 3 Specifications subject to change without notice. Split System Heat Pump LINE SET LENGTH AND SIZE BTUH SUCTION LINE SIZES LIQUID LINE SIZES 15 ft. 25 ft. 50 ft. 75 ft. 15 ft. 25 ft. 50 ft. 75 ft. 18 3/4 3/4 3/4 3/4 3/8 3/8 3/8 3/8 24 3/4 3/4 3/4 3/4 3/8 3/8 3/8 3/8 30 3/4 7/8 7/8 7/8 3/8 3/8 3/8 3/8 36 3/4 7/8 7/8 7/8 3/8 3/8 3/8 3/8 42 7/8 7/8 7/8 7/8 3/8 3/8 3/8 1/2 48 1 1/8 1 1/8 1 1/8 1 1/8 3/8 3/8 3/8 1/2 60 1 1/8 1 1/8 1 1/8 1 1/8 3/8 3/8 3/8 1/2 Recommended liquid & suction tube line size is for standard installations. The unit charge is correct for the outdoor unit, matched indoor coil and 15 feet of re...

Эта инструкция также подходит к моделям:
Насосное оборудование - CH18ABD1VF (131.37 kb)
Насосное оборудование - CH24ACD1VF (131.37 kb)
Насосное оборудование - CH36ACD1VF (131.37 kb)
Насосное оборудование - CH42ACD1VF (131.37 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории